{"id":101581,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101581"},"modified":"2026-07-02T19:11:15","modified_gmt":"2026-07-02T19:11:15","slug":"vibration-analyzer","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/da\/balancing-catalog\/vibration-analyzer\/","title":{"rendered":"Vibrationsanalysator og FFT-spektrum - Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/da\/balancing-catalog\/\">Balanceringsydelser<\/a> &rsaquo; Vibrationsanalysator<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Vibrationsanalysator &mdash; tokanals FFT-spektrum, fase &amp; fejldiagnostik<\/h1>\n<p class=\"lede\">Balanset-1A er en tokanals vibrationsanalysator, der viser FFT-spektre i realtid, m\u00e5ler amplitude og fase ved 1&times; RPM og kortl\u00e6gger fejlsignaturer for at skelne mellem ubalance, sk\u00e6vstilling, l\u00f8shed og lejeskader &mdash; og derefter afbalancerer i samme session. Et b\u00e6rbart s\u00e6t til &euro;1,975 d\u00e6kker diagnose, korrektion og verifikation uden at skifte instrument.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/da\/balanset-1a\/\">F\u00e5 fat i Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/da\/community\/\">Sp\u00f8rg vores ingeni\u00f8r<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/02\/interface-1-e1518391488191.webp\" alt=\"Balanset-1A vibrationsanalysator FFT-spektruminterface p\u00e5 b\u00e6rbar computer\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Kort sagt:<\/b> Balanset-1A-vibrationsanalysatoren registrerer samtidige tokanalssignaler fra sine to vibrationssensorer (analoge MEMS-accelerometre), beregner et FFT-spektrum i realtid og viser amplitude og fase ved hver akselordensharmoniske. Ubalance fremst\u00e5r som en dominerende 1&times; RPM-top; fejljustering som forh\u00f8jede 2&times;- og 3&times;-komponenter; udviklede lejeskader som BPFO-\/BPFI-toppe og sideb\u00e5nd; l\u00f8shed som subharmoniske komponenter. Fordi den samme hardware og de samme sensorer bruges til feltbalancering, kan du diagnosticere fejlen, korrigere den og verificere resultatet ved \u00e9t enkelt servicebes\u00f8g &mdash; med m\u00e5ling af vibrationshastighed fra 0.2 til 80&nbsp;mm\/s over 5 til 1000&nbsp;Hz.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#when\">Hvorn\u00e5r skal man analysere<\/a><br \/>\n<a href=\"#measures\">Hvad den m\u00e5ler<\/a><br \/>\n<a href=\"#faults\">Fejldiagnosticering<\/a><br \/>\n<a href=\"#how\">S\u00e5dan bruger du den<\/a><br \/>\n<a href=\"#standards\">Standarder<\/a><br \/>\n<a href=\"#device\">Balanset-1A<\/a><br \/>\n<a href=\"#screenshots\">Sk\u00e6rmbilleder<\/a><br \/>\n<a href=\"#cases\">Virkelige tilf\u00e6lde<\/a><br \/>\n<a href=\"#calc\">Beregnere<\/a><br \/>\n<a href=\"#faq\">OFTE STILLEDE SP\u00d8RGSM\u00c5L<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"when\">\n<h2>Tegn p\u00e5, at din maskine har brug for en vibrationsanalyse, ikke bare en m\u00e5lerafl\u00e6sning<\/h2>\n<p>Et enkelt overordnet vibrationstal fort\u00e6ller dig, at der er noget galt. Et FFT-spektrum fort\u00e6ller dig hvad og hvorfor. Disse situationer kr\u00e6ver en ordentlig analysator:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Ukendt \u00e5rsag til vibrationer<\/b> Det samlede niveau er forh\u00f8jet, men du kan ikke se, om synderen er ubalance, sk\u00e6vstilling, l\u00f8shed eller lejeskader &mdash; FFT adskiller hver signatur.<\/div>\n<div><b>St\u00e6rk 1\u00d7 RPM-komponent<\/b> En dominerende top af f\u00f8rste orden er den klassiske signatur for rotorens restubalance og signalet til at forts\u00e6tte med afbalancering.<\/div>\n<div><b>Forh\u00f8jede 2\u00d7 eller 3\u00d7 overtoner<\/b> En udpr\u00e6get anden- eller tredjeordenskomponent indikerer typisk vinkel- eller parallel sk\u00e6vstilling af koblinger eller aksler.<\/div>\n<div><b>Subharmonik eller bredb\u00e5ndsst\u00f8j<\/b> Lavordens lejeskadefrekvenser (BPFO, BPFI, BSF, FTF) og deres harmoniske optr\u00e6der i hastighedsspektret, efterh\u00e5nden som en skade udvikler sig &mdash; en advarsel, der er v\u00e6rd at trendoverv\u00e5ge f\u00f8r et nedbrud, selv om det helt tidlige skadestadium kr\u00e6ver h\u00f8jfrekvent enveloppeanalyse.<\/div>\n<div><b>Acceptkontrol efter reparation<\/b> Efter afbalancering, opretning eller lejeskift skal du have m\u00e5lt bevis for, at niveauerne er faldet til under ISO 20816-acceptgr\u00e6nsen.<\/div>\n<div><b>Periodisk unders\u00f8gelse af tilstandsoverv\u00e5gning<\/b> Ved at optage baseline-spektre med regelm\u00e6ssige intervaller kan du se tendenser til stigende amplituder og planl\u00e6gge vedligeholdelse f\u00f8r en uplanlagt nedlukning.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"measures\">\n<h2>Hvad Balanset-1A-analysatoren m\u00e5ler<\/h2>\n<p>Analysatoren registrerer samtidige signaler fra de to medf\u00f8lgende vibrationssensorer (analoge MEMS-accelerometre) refereret til lasertachometeret. Hver parameter, der er angivet nedenfor, er tilg\u00e6ngelig i \u00e9n enkelt m\u00e5lek\u00f8rsel:<\/p>\n<ul class=\"vbm-list\">\n<li>Samlet vibrationshastighed (mm\/s RMS) og acceleration (m\/s\u00b2 eller g)<\/li>\n<li>FFT-frekvensspektrum i realtid med brugervalgt opl\u00f8sning<\/li>\n<li>Vibrationsb\u00f8lgeform (tidsdom\u00e6nesignal) p\u00e5 begge kanaler samtidigt<\/li>\n<li>Fasevinkel ved 1&times; RPM i forhold til akslens tachometerreference<\/li>\n<li>1&times;-, 2&times;-, 3&times;- og h\u00f8jere akselordensamplituder udtrukket fra FFT'en<\/li>\n<li>Samtidig tokanalsregistrering (begge lejeplaner p\u00e5 \u00e9n gang)<\/li>\n<li>Driftshastighed (RPM) fra optisk lasertachometer &mdash; ingen navneplade n\u00f8dvendig<\/li>\n<li>Vibrationstrendlog over flere p\u00e5 hinanden f\u00f8lgende m\u00e5linger<\/li>\n<li>Printbar rapport: b\u00f8lgeform, spektrum og numerisk oversigt<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>up to &times;10<\/b><span>lejelevetid, n\u00e5r ubalancelasten halveres (ISO 281)<\/span><\/div>\n<div class=\"vbm-stat\"><b>&minus;70%<\/b><span>typisk vibrationsfald efter en afbalanceringssession<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>kanaler, samtidig opsamling<\/span><\/div>\n<div class=\"vbm-stat\"><b>5&ndash;1000&nbsp;Hz<\/b><span>Analysatorens frekvensomr\u00e5de<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"faults\">\n<h2>Fejldiagnostik &mdash; afl\u00e6sning af FFT-spektret<\/h2>\n<p>Hver mekanisk fejl efterlader et tydeligt spektralt fingeraftryk. Tabellen nedenfor kortl\u00e6gger de mest almindelige fejl med deres spektrale signaturer, s\u00e5 du kan afl\u00e6se maskinens tilstand direkte p\u00e5 Balanset-1A-displayet.<\/p>\n<table class=\"vbm-table\">\n<caption>Guide til diagnosticering af vibrationsfejl - spektrale signaturer<\/caption>\n<thead>\n<tr>\n<th>Fejl<\/th>\n<th>Dominerende spektrale komponenter<\/th>\n<th>Andre indikatorer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Ubalance i rotoren<\/b><\/td>\n<td>St\u00e6rk 1&times; RPM; alle andre ordener er lave<\/td>\n<td>Fasen er stabil; amplituden stiger med hastigheden i anden; bekr\u00e6ftet ved pr\u00f8vev\u00e6gtstest<\/td>\n<\/tr>\n<tr>\n<td><b>Vinkelforskydning<\/b><\/td>\n<td>Forh\u00f8jet 1\u00d7 og 2\u00d7; nogle gange 3\u00d7<\/td>\n<td>Aksial vibration er ofte lig med eller st\u00f8rre end radial; faseforskel over koblingen &asymp;180&deg;<\/td>\n<\/tr>\n<tr>\n<td><b>Parallel fejljustering<\/b><\/td>\n<td>St\u00e6rk 2\u00d7 RPM; 1\u00d7 kan ogs\u00e5 v\u00e6re til stede<\/td>\n<td>H\u00f8j radial vibration; 180&deg; faseforskydning m\u00e5lt over koblingen i radial retning<\/td>\n<\/tr>\n<tr>\n<td><b>Mekanisk l\u00f8shed<\/b><\/td>\n<td>Subharmoniske (0.5&times;, 0.33&times;) og flere harmoniske op til 10&times;<\/td>\n<td>Bredb\u00e5ndsst\u00f8jgulv forh\u00f8jet; symptomer forv\u00e6rres med belastning<\/td>\n<\/tr>\n<tr>\n<td><b>Slid p\u00e5 rullelejer<\/b><\/td>\n<td>BPFO-, BPFI-, BSF- eller FTF-fejlfrekvenser og deres harmoniske<\/td>\n<td>Kan forekomme, f\u00f8r det overordnede niveau stiger; sideb\u00e5nd omkring defektfrekvenser bekr\u00e6fter udviklingen<\/td>\n<\/tr>\n<tr>\n<td><b>Resonans<\/b><\/td>\n<td>Stor amplitude n\u00e6r en egenfrekvens, ofte ikke synkron med RPM<\/td>\n<td>Amplituden topper ved en bestemt hastighed; fasen skifter med ~180&deg; gennem resonans<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>N\u00e5r 1&times;-komponenten dominerer, skal du skifte direkte til afbalanceringstilstand &mdash; Balanset-1A bruger den samme m\u00e5lek\u00f8rsel som basislinje for beregningen af indflydelseskoefficienten, s\u00e5 ingen tid g\u00e5r tabt.<\/p>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Hvorfor et enkelt overordnet tal ikke d\u00e6kker over fejlen<\/h2>\n<p>En vibrationspen eller en simpel RMS-m\u00e5ler summerer alle frekvenskomponenter til \u00e9t tal. To maskiner kan vise identiske overordnede niveauer og alligevel have helt forskellige fejl &mdash; den ene er domineret af 1&times; ubalance, den anden af sideb\u00e5nd fra lejedefekter. Uden frekvensopl\u00f8sning g\u00e6tter du p\u00e5 \u00e5rsagen og risikerer at anvende det forkerte middel. FFT'en opdeler signalet, s\u00e5 hver fejltype vises som en m\u00e6rket top ved sin egen karakteristiske frekvens, hvilket giver dig b\u00e5de en diagnose og en l\u00f8sning i samme m\u00e5ling.<\/p>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> viser, hvorfor diagnosen er \u00f8konomisk vigtig. Den grundl\u00e6ggende nominelle levetid for rullelejer er <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b> (i millioner omdrejninger), hvor P er den \u00e6kvivalente dynamiske lejelast og p = 3 for kuglelejer (10\/3 for rullelejer). Restubalance tilf\u00f8jer en roterende komponent til denne last, s\u00e5 en halvering af 1&times;-vibrationsamplituden omtrent halverer ubalancelasten; hvor denne roterende last dominerer P, kan lejelevetiden \u00f8ges med op til 2<sup>p<\/sup>: om <b>8&times; for kuglelejer og ~10&times; for rullelejer<\/b>. Estimatet g\u00e6lder kun, n\u00e5r den m\u00e5lte 1&times;-vibration er en rimelig proxy for den roterende dynamiske lejelast. Brug <a href=\"https:\/\/vibromera.eu\/da\/calculators\/bearing-load\/\">Lejelevetids-beregner<\/a> for at kvantificere besparelsen for din maskine.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>S\u00e5dan bruger du Balanset-1A som vibrationsanalysator &mdash; trin for trin<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Monter sensorerne.<\/b> Fastg\u00f8r en eller begge vibrationssensorer til lejehusene ved hj\u00e6lp af de magnetiske monteringer. Til fase-refereret analyse skal du s\u00e6tte lasertachometerets refleksstrimmel p\u00e5 den roterende aksel og rette sensoren mod den (arbejdsomr\u00e5de 50&ndash;500&nbsp;mm). Begge kanaler registrerer samtidigt.<\/li>\n<li><b>Start rotoren, og foretag m\u00e5lingen.<\/b> \u00c5bn Balanset-softwaren, v\u00e6lg <em>Analysator<\/em> tilstand, og start optagelsen. Softwaren viser live-b\u00f8lgeform, FFT-spektrum og det samlede RMS-vibrationsniveau i mm\/s i realtid p\u00e5 en standard Windows-laptop.<\/li>\n<li><b>L\u00e6s spektret.<\/b> Identificer de dominerende frekvenstoppe. F\u00f8rste ordens amplitude og fase vises automatisk i forhold til tachopulsen. Se fejltabellen ovenfor for at matche det spektrale m\u00f8nster med den mest sandsynlige fejltype.<\/li>\n<li><b>Sammenlign med acceptgr\u00e6nser.<\/b> Kontroll\u00e9r den samlede hastighedsafl\u00e6sning i forhold til den relevante <b>ISO 20816<\/b> Zonegr\u00e6nsen (A\/B\/C\/D) for din maskinklasse og -effekt. Eksporter spektrumplottet og de numeriske v\u00e6rdier til vedligeholdelsesrapporten.<\/li>\n<li><b>Hvis ubalance bekr\u00e6ftes, skal du afbalancere i samme session.<\/b> Den baseline-m\u00e5ling, der allerede er taget, fungerer som den f\u00f8rste k\u00f8rsel i indflydelseskoefficient-sekvensen. Tilf\u00f8j en pr\u00f8vev\u00e6gt, k\u00f8r igen, og lad softwaren beregne korrektionen - ingen ekstra instrumenter, intet andet bes\u00f8g.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Standarder for vibrationsm\u00e5ling<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 20816<\/b> definerer evalueringszoner for vibrationshastighed (mm\/s RMS) p\u00e5 ikke-roterende dele: Zone A (nyligt idriftsat), B (acceptabel for langvarig drift), C (alarm &mdash; \u00f8jeblikkelig unders\u00f8gelse), D (fare &mdash; risiko for skade). Gr\u00e6nserne varierer efter maskinklasse og akselh\u00f8jde. Balanset-1A rapporterer den samlede hastighed i mm\/s RMS, s\u00e5 du kan sammenligne direkte med den relevante ISO 20816-del for din maskintype.<\/p>\n<p>N\u00e5r ubalancen er identificeret, evalueres den resterende ubalance efter afbalancering i forhold til <b>ISO 21940-11<\/b> G-grader (G0,4 til G40). Balanset-1A dokumenterer den opn\u00e5ede restubalance i den printbare rapport, hvilket giver dig en verificerbar registrering i forhold til den g\u00e6ldende standard. Brug den <a href=\"https:\/\/vibromera.eu\/da\/calculators\/residual-unbalance-iso1940\/\">Restubalance-beregner<\/a> for at finde den tilladte tolerance, f\u00f8r du g\u00e5r i gang.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A &mdash; dit komplette vibrationsanalyse- og afbalanceringss\u00e6t til brug p\u00e5 stedet<\/h2>\n<p>Alt p\u00e5 denne side er lavet med \u00e9t b\u00e6rbart instrument: den <a href=\"https:\/\/vibromera.eu\/da\/balanset-1a\/\">Balanset-1A<\/a>. Det er en dynamisk afbalancerings- og vibrationsanalysator med to kanaler, der diagnosticerer fejl ud fra FFT-spektret og afbalancerer stive rotorer, n\u00e5r ubalance er bekr\u00e6ftet. <strong>i deres egne lejer, ved driftshastighed<\/strong>, ved hj\u00e6lp af 3-k\u00f8rselsmetoden med indflydelseskoefficienter &mdash; softwaren beregner den n\u00f8jagtige korrektionsmasse og vinkel og gemmer en rapport.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Komplet Balanset-1A afbalanceringss\u00e6t med sensorer, lasertachometer, v\u00e6gt og kuffert\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Hvad indeholder det fulde s\u00e6t?<\/h3>\n<p class=\"price\">1.975 \u20ac <span>&middot; Fuldt kit, p\u00e5 lager, momsfaktura<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Interface-m\u00e5leenhed (USB, 2 kanaler)<\/li>\n<li>To vibrationsaccelerometre (4&nbsp;m kabel, 10&nbsp;m som ekstraudstyr)<\/li>\n<li>Laser-tachometer \/ optisk fasesensor (50&ndash;500&nbsp;mm)<\/li>\n<li>Magnetisk stativ til sensoren<\/li>\n<li>Digital v\u00e6gt til pr\u00f8ve- &amp; korrektionsv\u00e6gte<\/li>\n<li>Windows-software til afbalancering &amp; analyse<\/li>\n<li>Transportkasse af plast<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/da\/balanset-1a\/\">Se Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/da\/community\/\">Sp\u00f8rg vores ingeni\u00f8r<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Anbefalet<\/span><\/p>\n<h3>Fuldt s\u00e6t<\/h3>\n<p>Enhed - 2 sensorer - lasertachometer - magnetisk stativ - digital v\u00e6gt - software - transportkuffert. Alt, hvad der er n\u00f8dvendigt for at komme i gang med at afbalancere.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>OEM-s\u00e6t<\/h3>\n<p>Enhed &middot; 2 sensorer &middot; lasertachometer &middot; software. Til integratorer, der allerede har et stativ, en v\u00e6gt og en kasse, eller som integrerer enheden i en afbalanceringsmaskine.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Vigtige tekniske specifikationer<\/caption>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>V\u00e6rdi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M\u00e5lekanaler<\/td>\n<td>2 (afbalancering i et &amp; to planer)<\/td>\n<\/tr>\n<tr>\n<td>Vibrationshastighedsomr\u00e5de<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Frekvensomr\u00e5de<\/td>\n<td>5&ndash;1000 Hz (&le;10% amplitude error above 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>M\u00e5len\u00f8jagtighed<\/td>\n<td>&plusmn;5% af fuld skala<\/td>\n<\/tr>\n<tr>\n<td>Metode<\/td>\n<td>3-run indflydelseskoefficient (1 eller 2 planer)<\/td>\n<\/tr>\n<tr>\n<td>Analyse<\/td>\n<td>Amplitude &amp; fase ved 1&times;, FFT-spektrum &amp; b\u00f8lgeform, gemte rapporter<\/td>\n<\/tr>\n<tr>\n<td>B\u00e6rbar computer<\/td>\n<td>Ikke inkluderet (Windows PC, tilg\u00e6ngelig p\u00e5 foresp\u00f8rgsel)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>&#10003;<\/b> P\u00e5 lager<\/span><span><b>&#10003;<\/b> DHL Portugal &euro;35<\/span><span><b>&#10003;<\/b> DHL i hele verden &euro;110<\/span><span><b>&#10003;<\/b> 2 \u00e5rs garanti<\/span><span><b>&#10003;<\/b> Momsfaktura<\/span><span><b>&#10003;<\/b> Support til ingeni\u00f8rer<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"screenshots\">\n<h2>Hvad Balanset-1A-analysatoren viser<\/h2>\n<div class=\"vbm-cases\">\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/ChatGPT-Image-25-%D0%B8%D1%8E%D0%BB.-2025-%D0%B3.-22_07_35.webp\" alt=\"Balanset-1A to-kanals vibrationsanalysator - oversigtssk\u00e6rm\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Oversigt over tokanalsanalysatoren<\/h3>\n<p>Samlet vibrationsniveau, FFT-spektrum og fasevinkel fra to sensorer vises samtidigt p\u00e5 en Windows-laptop.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/09\/Screenshot-2025-07-29-165701-scaled.webp\" alt=\"FFT-spektrum i realtid, der viser frekvenstoppe til fejldiagnose\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>FFT-spektrum i realtid<\/h3>\n<p>Frekvenstoppe skelner mellem ubalance (dominerende 1&times;) og sk\u00e6vstilling (2&times;) samt sideb\u00e5nd fra lejedefekter.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/%D0%98%D0%B7%D0%BE%D0%B1%D1%80%D0%B0%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-WhatsApp-2025-10-03-%D0%B2-11.16.33_1bc14f9b.webp\" alt=\"Accelerometer og lasertachometer monteret p\u00e5 lejehus i marken\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>M\u00e5ling i marken<\/h3>\n<p>Vibrationssensor og lasertachometer monteret p\u00e5 lejehuset p\u00e5 en k\u00f8rende maskine &mdash; ingen demontering af maskinen n\u00f8dvendig.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10461221.webp\" alt=\"Amplitude og fase ved 1x RPM vist i Balanset-software\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Amplitude og fase ved 1\u00d7<\/h3>\n<p>F\u00f8rsteordens amplitude og fasevinkel vises mod tachometerreferencen &mdash; de input, der er n\u00f8dvendige for afbalancering med indflydelseskoefficientmetoden.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10418068.webp\" alt=\"Printbar Balanset-1A-m\u00e5lerapport med b\u00f8lgeform og spektrum\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dokumenteret rapport<\/h3>\n<p>B\u00f8lgeform, FFT-spektrum og numerisk oversigt eksporteres som en printbar rapport til vedligeholdelsesjournalen.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>\u00c6gte m\u00e5le- og analysecases<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/da\/eksempel\/maling-af-relativ-rotor-vibration-ved-brug-af-kontaktlose-lineaere-forskydningssensorer\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/image014.webp\" alt=\"Ber\u00f8ringsfri vibrationsm\u00e5ling med line\u00e6re forskydningssensorer\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Ber\u00f8ringsfri vibrationsm\u00e5ling<\/h3>\n<p>Brug af line\u00e6re forskydningssensorer til at m\u00e5le relativ rotorvibration uden akselkontakt - velegnet til rotorer, hvor accelerometermontering er upraktisk.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/da\/eksempel\/baerbar-balancer-vibrationsanalysator-og-balancer-maskine-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/photo_2023-04-08_17-03-49-1024x576.webp\" alt=\"Balanset-1A bruges b\u00e5de som vibrationsanalysator og afbalanceringsapparat i to planer\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Analysator og afbalanceringsinstrument kombineret<\/h3>\n<p>En praktisk demonstration af, hvordan en enhed d\u00e6kker vibrationsanalyse og afbalancering i to planer i et enkelt job, fra diagnose til verificeret korrektion.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/da\/eksempel\/why-balancing-doesnt-reduce-vibration-troubleshooting-guide-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/06\/ChatGPT-Image-19-%D0%B8%D1%8E%D0%BD.-2025-%D0%B3.-18_31_25.webp\" alt=\"Diagnosticering af, hvorfor afbalancering ikke reducerer vibrationer ved hj\u00e6lp af analysatoren\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Diagnosticer, f\u00f8r du afbalancerer<\/h3>\n<p>En fejlfindingsguide til tilf\u00e6lde, hvor afbalancering alene ikke reducerer vibrationer - og hvordan FFT-spektret afsl\u00f8rer den egentlige grund\u00e5rsag.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Gratis vibrationsberegnere<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/da\/calculators\/bearing-load\/\">Beregner af lejelevetid<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/da\/calculators\/centrifugal-force-unbalance\/\">Centrifugalkraft fra ubalance<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/da\/calculators\/residual-unbalance-iso1940\/\">Resterende ubalance (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/da\/calculators\/trial-weight-calculator\/\">Pr\u00f8vev\u00e6gt-beregner<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>Ofte stillede sp\u00f8rgsm\u00e5l om vibrationsanalysatorer<\/h2>\n<details>\n<summary>Hvordan skelner FFT-analyse mellem ubalance og sk\u00e6vstilling?<\/summary>\n<div class=\"ans\">Ubalance giver en enkelt dominerende top ved pr\u00e6cis 1&times; k\u00f8rehastigheden. Vinkelsk\u00e6vstilling viser typisk en st\u00e6rk 2&times;-komponent og nogle gange 3&times;, ofte med forh\u00f8jede aksiale vibrationer. Parallel sk\u00e6vstilling giver en fremtr\u00e6dende 2&times;-radial top. Balanset-1A markerer automatisk disse toppe i FFT-displayet, s\u00e5 du kan identificere den dominerende fejl, f\u00f8r du beslutter dig for en korrektion. Hvis 1&times;-komponenten dominerer, overf\u00f8res den samme m\u00e5ling direkte til afbalanceringsberegningen.<\/div>\n<\/details>\n<details>\n<summary>Kan jeg bruge Balanset-1A som en selvst\u00e6ndig analysator uden afbalancering?<\/summary>\n<div class=\"ans\">Ja. Enheden fungerer i en ren analysatortilstand til at registrere vibrationsspektre, m\u00e5le overordnede niveauer i mm\/s og logge data til tilstandsoverv\u00e5gningstendenser - uden at g\u00e5 i afbalanceringstilstand. Dette er nyttigt til indg\u00e5ende inspektion, periodiske tilstandsunders\u00f8gelser og godkendelsesm\u00e5linger efter reparation i forhold til ISO 20816-gr\u00e6nser.<\/div>\n<\/details>\n<details>\n<summary>Hvilket frekvensomr\u00e5de d\u00e6kker FFT'en, og er det nok til lejediagnostik?<\/summary>\n<div class=\"ans\">Balanset-1A d\u00e6kker 5 til 1000&nbsp;Hz, hvilket opfanger alle akselordensharmoniske plus de grundl\u00e6ggende lejeskadefrekvenser (BPFO, BPFI, BSF, FTF) og deres lavere harmoniske for de fleste industrielle rullelejer ved typiske hastigheder. V\u00e6r dog opm\u00e6rksom p\u00e5 begr\u00e6nsningen: Lejeskader i tidligt stadie registreres normalt med h\u00f8jfrekvent acceleration og envelope- (demodulations-)teknikker, som kr\u00e6ver b\u00e5ndbredde fra flere kHz til titusinder af kHz &mdash; uden for dette instruments omr\u00e5de. Inden for 5&ndash;1000&nbsp;Hz viser Balanset-1A lejeskader, n\u00e5r de producerer m\u00e5lbare hastighedskomponenter ved skadedefektsfrekvenserne, dvs. p\u00e5 et mere udviklet stadie; det er ikke en erstatning for et dedikeret bredb\u00e5ndsinstrument til leje-diagnostik.<\/div>\n<\/details>\n<details>\n<summary>G\u00e6lder ISO 20816 for min maskine?<\/summary>\n<div class=\"ans\">ISO 20816 d\u00e6kker en bred vifte af roterende maskiner p\u00e5 tv\u00e6rs af deres mange dele: pumper, kompressorer, ventilatorer, turbiner, motorer og generatorer er alle omfattet. Den specifikke zonegr\u00e6nse afh\u00e6nger af maskinens effektklasse og akselcenterh\u00f8jde. Balanset-1A rapporterer den samlede hastighed i mm\/s RMS, s\u00e5 du kan anvende den del af ISO 20816, der d\u00e6kker din maskintype, direkte p\u00e5 afl\u00e6sningen.<\/div>\n<\/details>\n<details>\n<summary>Er fasem\u00e5lingen n\u00f8jagtig nok til afbalancering i to planer?<\/summary>\n<div class=\"ans\">Ja. Fase m\u00e5les i forhold til den optiske tachometerpuls, hvilket giver en gentagelig vinkelreference. Den samtidige opsamling med to kanaler sikrer, at begge lejeplaner samples ved samme akselposition, hvilket er afg\u00f8rende for n\u00f8jagtige beregninger af krydseffekten (indflydelseskoefficienten) i dynamiske afbalanceringsopgaver med to planer.<\/div>\n<\/details>\n<details>\n<summary>Hvordan hj\u00e6lper analysatoren, n\u00e5r afbalancering alene ikke l\u00f8ste vibrationen?<\/summary>\n<div class=\"ans\">N\u00e5r afbalancering reducerer 1&times;-komponenten, men den samlede vibration stadig er h\u00f8j, viser FFT'en straks, hvilken anden frekvenskomponent der er blevet dominerende &mdash; uanset om det er en 2&times;-harmonisk fra sk\u00e6vstilling, en lejedefektfrekvens eller en subharmonisk l\u00f8shedssignatur. P\u00e5 den m\u00e5de kan det n\u00e6ste korrigerende trin styres pr\u00e6cist i stedet for at lade teknikeren g\u00e6tte. Se vores casestudie om diagnosticering af vedvarende vibrationer for praktiske eksempler.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>L\u00e6r teorien at kende<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/da\/glossary\/feltbalancering\/\">Balancering p\u00e5 stedet<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/da\/glossary\/residual-unbalance\/\">Resterende ubalance<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/da\/glossary\/balance-quality\/\">Balancekvalitetsgrader<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/da\/glossary\/dynamic-balancing\/\">Dynamisk afbalancering<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Diagnostic\u00e9r f\u00f8rst - og balancer derefter med selvtillid<\/h2>\n<p>Balanset-1A giver dig en tokanals FFT-analysator og et afbalanceringsinstrument til to planer i \u00e9t b\u00e6rbart s\u00e6t. Afl\u00e6s fejlen i spektret, ret den ved kilden, og verificer i henhold til ISO 20816 &mdash; alt sammen p\u00e5 et enkelt bes\u00f8g p\u00e5 stedet for &euro;1,975.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/da\/balanset-1a\/\">Se Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/da\/community\/\">Stil et sp\u00f8rgsm\u00e5l p\u00e5 forummet<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Vibration Analyzer Vibration Analyzer &mdash; Two-Channel FFT Spectrum, Phase &amp; Fault Diagnostics The Balanset-1A is a two-channel vibration analyzer that plots real-time FFT spectra, measures amplitude and phase at 1&times; RPM, and maps fault signatures to distinguish unbalance, misalignment, looseness and bearing damage &mdash; then balances in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101581","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/pages\/101581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/comments?post=101581"}],"version-history":[{"count":6,"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/pages\/101581\/revisions"}],"predecessor-version":[{"id":102102,"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/pages\/101581\/revisions\/102102"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/da\/wp-json\/wp\/v2\/media?parent=101581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}