{"id":1204,"date":"2018-11-05T20:45:31","date_gmt":"2018-11-05T20:45:31","guid":{"rendered":"https:\/\/vibromera.eu\/?p=1204"},"modified":"2026-07-02T18:43:30","modified_gmt":"2026-07-02T18:43:30","slug":"bombas-hidraulicas-balanceo","status":"publish","type":"post","link":"https:\/\/vibromera.eu\/es-mx\/example\/hydraulic-pumps-balancing\/","title":{"rendered":"Balanceo de bombas hidr\u00e1ulicas"},"content":{"rendered":"<div id=\"pl-1204\"  class=\"panel-layout\" ><div id=\"pg-1204-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-1204-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1204-0-0-0\" class=\"so-panel widget widget_woocommerce_products woocommerce widget_products panel-first-child\" data-index=\"0\" ><h3 class=\"widget-title\">Productos<\/h3><ul class=\"product_list_widget\"><li>\n\t\n\t<a href=\"https:\/\/vibromera.eu\/sr\/%d0%bf%d1%80%d0%be%d0%b8%d0%b7%d0%b2%d0%be%d0%b4\/balanset-1\/\">\n\t\t<img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"153\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/09\/77-e1693745667801-230x153.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Balanset-1A full kit portable balancer and vibration analyzer\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/09\/77-e1693745667801-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/09\/77-e1693745667801-18x12.webp 18w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/09\/77-e1693745667801-360x240.webp 360w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/09\/77-e1693745667801-272x182.webp 272w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/>\t\t<span class=\"product-title\">Balancero port\u00e1til y analizador de vibraci\u00f3n Balanset-1A<\/span>\n\t<\/a>\n\n\t\t\t\t\n\t<span class=\"woocommerce-Price-amount amount\"><bdi><span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span>1,975.00<\/bdi><\/span> <small class=\"woocommerce-price-suffix\">+ IVA (si aplica)<\/small>\n\t<\/li>\n<li>\n\t\n\t<a href=\"https:\/\/vibromera.eu\/sr\/%d0%bf%d1%80%d0%be%d0%b8%d0%b7%d0%b2%d0%be%d0%b4\/dynamic-balancer-balanset-1a\/\">\n\t\t<img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"153\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-230x153.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Balanset-1A kit contents with interface unit, sensors, tachometer and accessories\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-600x400.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-300x200.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-1024x683.webp 1024w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-768x512.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-1536x1024.webp 1536w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-2048x1366.webp 2048w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-360x240.webp 360w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-272x182.webp 272w, https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/\u0411\u0430\u043b\u043a\u043e\u043c\u041a\u0438\u0442-scaled-e1732998877834.webp 708w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/>\t\t<span class=\"product-title\">Balancero din\u00e1mico \u201cBalanset-1A\u201d OEM<\/span>\n\t<\/a>\n\n\t\t\t\t\n\t<span class=\"woocommerce-Price-amount amount\"><bdi><span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span>1,735.00<\/bdi><\/span> <small class=\"woocommerce-price-suffix\">+ IVA (si aplica)<\/small>\n\t<\/li>\n<li>\n\t\n\t<a href=\"https:\/\/vibromera.eu\/sr\/%d0%bf%d1%80%d0%be%d0%b8%d0%b7%d0%b2%d0%be%d0%b4\/vibration-sensor\/\">\n\t\t<img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"153\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-230x153.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Balanset-1A vibration sensor close-up\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-600x400.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-300x200.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-768x512.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-1024x682.webp 1024w, https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3-272x182.webp 272w, https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/05\/IMG-3.webp 1280w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/>\t\t<span class=\"product-title\">Sensor de vibraci\u00f3n<\/span>\n\t<\/a>\n\n\t\t\t\t\n\t<span class=\"woocommerce-Price-amount amount\"><bdi><span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span>90.00<\/bdi><\/span> <small class=\"woocommerce-price-suffix\">+ IVA (si aplica)<\/small>\n\t<\/li>\n<li>\n\t\n\t<a href=\"https:\/\/vibromera.eu\/sr\/%d0%bf%d1%80%d0%be%d0%b8%d0%b7%d0%b2%d0%be%d0%b4\/optical-sensor-for-balanset-and-arbalance\/\">\n\t\t<img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"153\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-230x153.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Sensor \u00f3ptico (tac\u00f3metro l\u00e1ser)\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-300x200.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-1024x682.webp 1024w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-768x512.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-1536x1023.webp 1536w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-18x12.webp 18w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-360x240.webp 360w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-460x306.webp 460w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-600x400.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU-272x182.webp 272w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/ZKqzGXSCCBU.webp 1600w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/>\t\t<span class=\"product-title\">Sensor \u00f3ptico (tac\u00f3metro l\u00e1ser)<\/span>\n\t<\/a>\n\n\t\t\t\t\n\t<span class=\"woocommerce-Price-amount amount\"><bdi><span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span>124.00<\/bdi><\/span> <small class=\"woocommerce-price-suffix\">+ IVA (si aplica)<\/small>\n\t<\/li>\n<li>\n\t\n\t<a href=\"https:\/\/vibromera.eu\/sr\/%d0%bf%d1%80%d0%be%d0%b8%d0%b7%d0%b2%d0%be%d0%b4\/balanset-4\/\">\n\t\t<img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"153\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-230x153.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Vibromera rotor balancing kit: carry case, multi-channel signal conditioner, handheld analyzer, magnetic base, vibration sensors, and coiled cables.\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-300x200.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-18x12.webp 18w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-360x240.webp 360w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-460x306.webp 460w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-600x400.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4-272x182.webp 272w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/balkom4.webp 640w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/>\t\t<span class=\"product-title\">Balanset-4<\/span>\n\t<\/a>\n\n\t\t\t\t\n\t<span class=\"woocommerce-Price-amount amount\"><bdi><span class=\"woocommerce-Price-currencySymbol\" translate=\"no\">&euro;<\/span>6,803.00<\/bdi><\/span> <small class=\"woocommerce-price-suffix\">+ IVA (si aplica)<\/small>\n\t<\/li>\n<\/ul><\/div><div id=\"panel-1204-0-0-1\" class=\"widget_text so-panel widget widget_custom_html\" data-index=\"1\" ><div class=\"textwidget custom-html-widget\"><!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    \n    <meta name=\"keywords\" content=\"hydraulic pump balancing, dynamic balancing, Balanset-1A, vibration reduction, rotor balancing, pump maintenance, in-situ balancing\">\n    <meta name=\"author\" content=\"Vibromera Engineering Team\">\n    \n    \n    \n    <title>Hydraulic Pump Balancing Using Balanset-1A Device<\/title>\n    <style>\n        body {\n            font-family: Arial, sans-serif;\n            line-height: 1.6;\n            color: #2c3e50;\n            margin: 0 auto;\n            padding: 20px;\n            background-color: #f8fbff;\n        }\n        \n        .header {\n            background: linear-gradient(135deg, #3498db 0%, #2980b9 100%);\n            color: white;\n            padding: 40px 30px;\n            border-radius: 8px;\n            margin-bottom: 30px;\n            text-align: center;\n        }\n        \n        .header h1 {\n            font-size: 2.5em;\n            margin: 0 0 15px 0;\n            font-weight: normal;\n        }\n        \n        .header .subtitle {\n            font-size: 1.1em;\n            opacity: 0.9;\n        }\n        \n        .section {\n            background: white;\n            margin: 25px 0;\n            padding: 30px;\n            border-radius: 8px;\n            box-shadow: 0 2px 10px rgba(52, 152, 219, 0.1);\n            border-left: 4px solid #3498db;\n        }\n        \n        .section h2 {\n            color: #2980b9;\n            font-size: 1.8em;\n            margin-top: 0;\n            margin-bottom: 20px;\n            font-weight: normal;\n        }\n        \n        .section h3 {\n            color: #34495e;\n            font-size: 1.3em;\n            margin-top: 25px;\n            margin-bottom: 15px;\n        }\n        \n        .tech-specs {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n            gap: 20px;\n            margin: 20px 0;\n        }\n        \n        .spec-card {\n            background: #ecf0f1;\n            padding: 20px;\n            border-radius: 6px;\n            border-left: 3px solid #3498db;\n        }\n        \n        .spec-card h4 {\n            color: #2980b9;\n            margin-top: 0;\n            margin-bottom: 15px;\n        }\n        \n        .spec-table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 20px 0;\n            background: white;\n        }\n        \n        .spec-table th {\n            background: #3498db;\n            color: white;\n            padding: 12px;\n            text-align: left;\n            font-weight: normal;\n        }\n        \n        .spec-table td {\n            padding: 10px 12px;\n            border-bottom: 1px solid #bdc3c7;\n        }\n        \n        .spec-table tr:nth-child(even) {\n            background: #f8f9fa;\n        }\n        \n        .infographic {\n            background: #ecf0f1;\n            border: 1px solid #bdc3c7;\n            border-radius: 6px;\n            padding: 25px;\n            margin: 25px 0;\n            text-align: center;\n        }\n        \n        .process-steps {\n            counter-reset: step-counter;\n        }\n        \n        .process-step {\n            counter-increment: step-counter;\n            margin: 20px 0;\n            padding: 20px;\n            background: #f8f9fa;\n            border-radius: 6px;\n            border-left: 4px solid #3498db;\n            position: relative;\n        }\n        \n        .process-step::before {\n            content: counter(step-counter);\n            position: absolute;\n            left: -12px;\n            top: -12px;\n            background: #3498db;\n            color: white;\n            width: 24px;\n            height: 24px;\n            border-radius: 50%;\n            display: flex;\n            align-items: center;\n            justify-content: center;\n            font-size: 14px;\n            font-weight: bold;\n        }\n        \n        .process-step h4 {\n            color: #2980b9;\n            margin-top: 0;\n            margin-bottom: 10px;\n        }\n        \n        .warning-box {\n            background: #e8f4fd;\n            border: 1px solid #3498db;\n            padding: 15px;\n            margin: 15px 0;\n            border-radius: 4px;\n            border-left: 4px solid #e74c3c;\n        }\n        \n        .info-box {\n            background: #e8f4fd;\n            border: 1px solid #3498db;\n            padding: 15px;\n            margin: 15px 0;\n            border-radius: 4px;\n        }\n        \n        ul {\n            padding-left: 20px;\n        }\n        \n        li {\n            margin: 8px 0;\n        }\n        \n        .equipment-list {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 15px;\n            margin: 20px 0;\n        }\n        \n        .equipment-item {\n            background: #f8f9fa;\n            padding: 15px;\n            border-radius: 4px;\n            border-left: 3px solid #3498db;\n        }\n        \n        .equipment-item strong {\n            color: #2980b9;\n        }\n        \n        @media (max-width: 768px) {\n            .header h1 {\n                font-size: 2em;\n            }\n            \n            .section {\n                padding: 20px;\n            }\n            \n            .tech-specs {\n                grid-template-columns: 1fr;\n            }\n        }\n    <\/style>\n    \n    \n<\/head>\n<body>\n    <div class=\"header\">\n        <h1>Hydraulic Pump Balancing with the Balanset-1A Device<\/h1>\n        <p class=\"subtitle\">A practical guide for maintenance engineers and technicians, covering dynamic balancing technology using the portable Balanset-1A device<\/p>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>1. Prop\u00f3sito y Principio de Funcionamiento<\/h2>\n        \n        <p>El balanceo de bombas hidr\u00e1ulicas es un procedimiento para eliminar el desbalance de las partes giratorias con el fin de reducir la vibraci\u00f3n y aumentar la vida \u00fatil del equipo.<\/p>\n        <p>The balancing process involves measuring the rotor&rsquo;s vibration and phase, then adding or removing small correction weights on the impeller or shaft. By counteracting the uneven mass distribution, this procedure significantly reduces the centrifugal forces that cause vibration and potential damage.<\/p>\n        \n        <h3>Causas principales del desbalance:<\/h3>\n        <ul>\n            <li>Imprecisiones de fabricaci\u00f3n del impulsor y el eje<\/li>\n            <li>Desgaste y da\u00f1os durante la operaci\u00f3n<\/li>\n            <li>Da\u00f1os por corrosi\u00f3n y cavitaci\u00f3n<\/li>\n            <li>Montaje incorrecto despu\u00e9s de la reparaci\u00f3n<\/li>\n        <\/ul>\n        \n        <h3>Consecuencias del desbalance:<\/h3>\n        <ul>\n            <li>Aumento de la vibraci\u00f3n y el ruido<\/li>\n            <li>Desgaste acelerado de rodamientos y sellos<\/li>\n            <li>Reducci\u00f3n de la eficiencia de la bomba<\/li>\n            <li>Riesgo de falla de emergencia<\/li>\n        <\/ul>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>2. Descripci\u00f3n T\u00e9cnica del Balanset-1A<\/h2>\n        \n        <p><a href=\"https:\/\/vibromera.eu\/es-mx\/producto\/balanset-1\/\">Balanset-1A<\/a> is a portable dual-channel device for dynamic balancing of rotors directly at the workplace (in-situ).<\/p>\n        \n        <div class=\"infographic\">\n            <h4>Estructura del Sistema Balanset-1A<\/h4>\n            <svg width=\"600\" height=\"300\" viewbox=\"0 0 600 300\">\n                <title>Balanset-1A system structure diagram with sensors, tachometer, measuring unit, and laptop<\/title>\n                <!-- USB \u0431\u043b\u043e\u043a -->\n                <rect x=\"50\" y=\"120\" width=\"80\" height=\"60\" fill=\"#3498db\" stroke=\"#2980b9\" stroke-width=\"2\" rx=\"5\"\/>\n                <text x=\"90\" y=\"145\" text-anchor=\"middle\" font-size=\"12\" fill=\"white\" font-weight=\"bold\">USB<\/text>\n                <text x=\"90\" y=\"160\" text-anchor=\"middle\" font-size=\"12\" fill=\"white\">Interfaz<\/text>\n                \n                <!-- \u0414\u0430\u0442\u0447\u0438\u043a\u0438 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438 -->\n                <circle cx=\"200\" cy=\"100\" r=\"25\" fill=\"#27ae60\" stroke=\"#229954\" stroke-width=\"2\"\/>\n                <text x=\"200\" y=\"105\" text-anchor=\"middle\" font-size=\"10\" fill=\"white\">Sensor 1<\/text>\n                \n                <circle cx=\"200\" cy=\"200\" r=\"25\" fill=\"#27ae60\" stroke=\"#229954\" stroke-width=\"2\"\/>\n                <text x=\"200\" y=\"205\" text-anchor=\"middle\" font-size=\"10\" fill=\"white\">Sensor 2<\/text>\n                \n                <!-- \u041b\u0430\u0437\u0435\u0440\u043d\u044b\u0439 \u0442\u0430\u0445\u043e\u043c\u0435\u0442\u0440 -->\n                <rect x=\"170\" y=\"40\" width=\"60\" height=\"30\" fill=\"#e74c3c\" stroke=\"#c0392b\" stroke-width=\"2\" rx=\"3\"\/>\n                <text x=\"200\" y=\"58\" text-anchor=\"middle\" font-size=\"10\" fill=\"white\">Tac\u00f3metro<\/text>\n                \n                <!-- \u041d\u043e\u0443\u0442\u0431\u0443\u043a -->\n                <rect x=\"400\" y=\"100\" width=\"120\" height=\"80\" fill=\"#95a5a6\" stroke=\"#7f8c8d\" stroke-width=\"2\" rx=\"5\"\/>\n                <rect x=\"410\" y=\"110\" width=\"100\" height=\"60\" fill=\"#ecf0f1\" stroke=\"#bdc3c7\" stroke-width=\"1\"\/>\n                <text x=\"460\" y=\"145\" text-anchor=\"middle\" font-size=\"12\" fill=\"#2c3e50\">Port\u00e1til<\/text>\n                \n                <!-- \u0421\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043b\u0438\u043d\u0438\u0438 -->\n                <line x1=\"130\" y1=\"150\" x2=\"170\" y2=\"110\" stroke=\"#3498db\" stroke-width=\"2\"\/>\n                <line x1=\"130\" y1=\"150\" x2=\"170\" y2=\"190\" stroke=\"#3498db\" stroke-width=\"2\"\/>\n                <line x1=\"130\" y1=\"140\" x2=\"170\" y2=\"55\" stroke=\"#3498db\" stroke-width=\"2\"\/>\n                <line x1=\"130\" y1=\"150\" x2=\"400\" y2=\"140\" stroke=\"#3498db\" stroke-width=\"2\"\/>\n                \n                <!-- \u041f\u043e\u0434\u043f\u0438\u0441\u0438 -->\n                <text x=\"90\" y=\"200\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2c3e50\">Unidad de medici\u00f3n<\/text>\n                <text x=\"200\" y=\"240\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2c3e50\">Sensores de vibraci\u00f3n<\/text>\n                <text x=\"460\" y=\"200\" text-anchor=\"middle\" font-size=\"11\" fill=\"#2c3e50\">Software Balanset-1A<\/text>\n            <\/svg>\n        <\/div>\n        \n        <h3>Especificaciones t\u00e9cnicas<\/h3>\n        \n        <table class=\"spec-table\">\n            <thead>\n                <tr>\n                    <th>Par\u00e1metro<\/th>\n                    <th>Valor<\/th>\n                    <th>Unidad<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>Rango de medici\u00f3n de velocidad de vibraci\u00f3n (RMS)<\/td>\n                    <td>0.02 - 80<\/td>\n                    <td>mm\/s<\/td>\n                <\/tr>\n                <tr>\n                    <td>Rango de frecuencia<\/td>\n                    <td>5 - 1000<\/td>\n                    <td>Hz<\/td>\n                <\/tr>\n                <tr>\n                    <td>Rango de medici\u00f3n de velocidad de rotaci\u00f3n<\/td>\n                    <td>100 - 100,000<\/td>\n                    <td>rpm<\/td>\n                <\/tr>\n                <tr>\n                    <td>Precisi\u00f3n de medici\u00f3n de fase<\/td>\n                    <td>\u00b11<\/td>\n                    <td>grados<\/td>\n                <\/tr>\n                <tr>\n                    <td>N\u00famero de planos de correcci\u00f3n<\/td>\n                    <td>1 o 2<\/td>\n                    <td>-<\/td>\n                <\/tr>\n                <tr>\n                    <td>Temperatura de operaci\u00f3n<\/td>\n                    <td>+5...+50<\/td>\n                    <td>\u00b0C<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n        \n        <h3>Contenido del paquete del dispositivo<\/h3>\n        \n        <div class=\"equipment-list\">\n            <div class=\"equipment-item\">\n                <strong>Unidad de medici\u00f3n<\/strong><br>\n                Interfaz USB con preamplificadores y ADC\n            <\/div>\n            <div class=\"equipment-item\">\n                <strong>Sensores de vibraci\u00f3n<\/strong><br>\n                2 aceler\u00f3metros con montaje magn\u00e9tico\n            <\/div>\n            <div class=\"equipment-item\">\n                <strong>Tac\u00f3metro l\u00e1ser<\/strong><br>\n                Sensor de fase con soporte magn\u00e9tico\n            <\/div>\n            <div class=\"equipment-item\">\n                <strong>Cinta reflectante<\/strong><br>\n                Para instalaci\u00f3n en el eje de la bomba\n            <\/div>\n            <div class=\"equipment-item\">\n                <strong>Balanza electr\u00f3nica<\/strong><br>\n                Para medici\u00f3n precisa de peso\n            <\/div>\n            <div class=\"equipment-item\">\n                <strong>Software<\/strong><br>\n                En memoria USB con instrucciones\n            <\/div>\n        <\/div>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>3. Preparaci\u00f3n para el balanceo<\/h2>\n        \n        <div class=\"warning-box\">\n            <strong>Requisitos de seguridad:<\/strong> Before starting work, disconnect pump power, install barriers, and check equipment mounting reliability.\n        <\/div>\n        \n        <h3>Instalaci\u00f3n del sensor<\/h3>\n        \n        <div class=\"infographic\">\n            <h4>Diagrama de instalaci\u00f3n del sensor en la bomba hidr\u00e1ulica<\/h4>\n            <svg width=\"500\" height=\"250\" viewbox=\"0 0 500 250\">\n                <title>Hydraulic pump diagram with vibration sensors, reflective tape on the shaft, and a laser tachometer for balancing setup<\/title>\n                <!-- \u041a\u043e\u0440\u043f\u0443\u0441 \u043d\u0430\u0441\u043e\u0441\u0430 -->\n                <rect x=\"100\" y=\"80\" width=\"200\" height=\"90\" fill=\"#bdc3c7\" stroke=\"#95a5a6\" stroke-width=\"2\" rx=\"5\"\/>\n                <text x=\"200\" y=\"130\" text-anchor=\"middle\" font-weight=\"bold\" fill=\"#2c3e50\">BOMBA<\/text>\n                \n                <!-- \u0412\u0430\u043b -->\n                <line x1=\"300\" y1=\"125\" x2=\"400\" y2=\"125\" stroke=\"#34495e\" stroke-width=\"6\"\/>\n                \n                <!-- \u041f\u043e\u0434\u0448\u0438\u043f\u043d\u0438\u043a\u043e\u0432\u044b\u0435 \u0443\u0437\u043b\u044b -->\n                <rect x=\"280\" y=\"110\" width=\"30\" height=\"30\" fill=\"#7f8c8d\" rx=\"3\"\/>\n                <rect x=\"370\" y=\"110\" width=\"30\" height=\"30\" fill=\"#7f8c8d\" rx=\"3\"\/>\n                \n                <!-- \u0414\u0430\u0442\u0447\u0438\u043a\u0438 \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u0438 -->\n                <rect x=\"270\" y=\"70\" width=\"20\" height=\"25\" fill=\"#27ae60\" rx=\"2\"\/>\n                <rect x=\"375\" y=\"70\" width=\"20\" height=\"25\" fill=\"#27ae60\" rx=\"2\"\/>\n                \n                <!-- \u041b\u0430\u0437\u0435\u0440\u043d\u044b\u0439 \u0442\u0430\u0445\u043e\u043c\u0435\u0442\u0440 -->\n                <rect x=\"340\" y=\"40\" width=\"30\" height=\"15\" fill=\"#e74c3c\" rx=\"2\"\/>\n                \n                <!-- \u041e\u0442\u0440\u0430\u0436\u0430\u044e\u0449\u0430\u044f \u043b\u0435\u043d\u0442\u0430 -->\n                <rect x=\"350\" y=\"115\" width=\"8\" height=\"20\" fill=\"#f39c12\"\/>\n                \n                <!-- \u041f\u043e\u0434\u043f\u0438\u0441\u0438 -->\n                <text x=\"280\" y=\"65\" text-anchor=\"middle\" font-size=\"10\" fill=\"#27ae60\">Sensor 1<\/text>\n                <text x=\"385\" y=\"65\" text-anchor=\"middle\" font-size=\"10\" fill=\"#27ae60\">Sensor 2<\/text>\n                <text x=\"355\" y=\"35\" text-anchor=\"middle\" font-size=\"10\" fill=\"#e74c3c\">Tac\u00f3metro<\/text>\n                <text x=\"354\" y=\"155\" text-anchor=\"middle\" font-size=\"9\" fill=\"#f39c12\">Cinta<\/text>\n                \n                <!-- \u0421\u0442\u0440\u0435\u043b\u043a\u0438 \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f -->\n                <path d=\"M 280 95 L 285 90 L 285 100 Z\" fill=\"#27ae60\"\/>\n                <path d=\"M 385 95 L 390 90 L 390 100 Z\" fill=\"#27ae60\"\/>\n                <path d=\"M 355 55 L 360 50 L 360 60 Z\" fill=\"#e74c3c\"\/>\n            <\/svg>\n        <\/div>\n        \n        <ul>\n            <li>Install vibration sensors on the pump housing near the bearings, oriented perpendicular to the shaft axis<\/li>\n            <li>Attach reflective tape on the pump shaft or coupling<\/li>\n            <li>Mount the laser tachometer on a magnetic stand opposite the reflective tape<\/li>\n            <li>Connect the sensors to the measuring unit<\/li>\n            <li>Connect the measuring unit to the laptop via USB<\/li>\n        <\/ul>\n        \n        <div class=\"info-box\">\n            <strong>Importante:<\/strong> Sensors must be securely mounted and aligned perpendicular to the shaft rotation axis.\n        <\/div>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>4. Procedimiento de balanceo<\/h2>\n        \n        <p>The balancing procedure with Balanset-1A typically follows a three-run method (influence coefficient method) using trial weights. Below is a step-by-step outline of the process, from measuring initial vibration to installing correction weights and verifying the results.<\/p>\n        \n        <div class=\"process-steps\">\n            <div class=\"process-step\">\n                <h4>Medici\u00f3n inicial de vibraci\u00f3n<\/h4>\n                <ul>\n                    <li>Inicie el software Balanset-1A<\/li>\n                    <li>Seleccione el modo de balanceo en un plano o en dos planos<\/li>\n                    <li>Start the pump at operating speed<\/li>\n                    <li>Press \"Run#0\" in the software to measure initial vibration<\/li>\n                    <li>Record the vibration amplitude and phase values<\/li>\n                <\/ul>\n                <div class=\"info-box\">\n                    Ensure that the pump's rotation speed is stable before starting measurements.\n                <\/div>\n            <\/div>\n            \n            <div class=\"process-step\">\n                <h4>Instalaci\u00f3n del peso de prueba<\/h4>\n                <ul>\n                    <li>Detenga la bomba<\/li>\n                    <li>Weigh a suitable trial weight using the electronic scales<\/li>\n                    <li>Install the weight on the rotor in the first correction plane<\/li>\n                    <li>Enter the weight\u2019s mass and installation radius into the software<\/li>\n                    <li>Restart the pump and perform the \"Run#1\" measurement<\/li>\n                <\/ul>\n                <div class=\"warning-box\">\n                    Trial weight should cause at least a 20% change in vibration amplitude or phase to ensure effective measurement.\n                <\/div>\n            <\/div>\n            \n            <div class=\"process-step\">\n                <h4>Medici\u00f3n del segundo plano (para balanceo en dos planos)<\/h4>\n                <ul>\n                    <li>Stop the pump and remove the trial weight from the first plane<\/li>\n                    <li>Attach the trial weight to the second correction plane<\/li>\n                    <li>Start the pump and perform the \"Run#2\" measurement<\/li>\n                    <li>The software will automatically calculate the required correction weights<\/li>\n                <\/ul>\n            <\/div>\n            \n            <div class=\"process-step\">\n                <h4>Instalaci\u00f3n del peso de correcci\u00f3n<\/h4>\n                <ul>\n                    <li>Stop the pump and remove any trial weights<\/li>\n                    <li>Manufacture or select the correction weights as per the software\u2019s calculation<\/li>\n                    <li>Secure the weights by welding, bolting, or using clamps<\/li>\n                    <li>The installation angle for each weight is measured from the trial weight position in the direction of rotation<\/li>\n                <\/ul>\n            <\/div>\n            \n            <div class=\"process-step\">\n                <h4>Medici\u00f3n de verificaci\u00f3n<\/h4>\n                <ul>\n                    <li>Run the pump at operating speed<\/li>\n                    <li>Perform a control measurement (\"RunTrim\")<\/li>\n                    <li>Verify that vibration has been reduced to acceptable levels<\/li>\n                    <li>Adjust weight masses and repeat measurement if necessary<\/li>\n                <\/ul>\n            <\/div>\n        <\/div>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>5. Criterios de evaluaci\u00f3n de la calidad del balanceo<\/h2>\n        \n        <h3>Valores aceptables de vibraci\u00f3n residual<\/h3>\n        \n        <table class=\"spec-table\">\n            <thead>\n                <tr>\n                    <th>Pump category (ISO&nbsp;10816-7)<\/th>\n                    <th>Acceptable for long-term operation (zone B limit), mm\/s RMS<\/th>\n                    <th>Risk of damage (zone D), mm\/s RMS<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>Category I (high-reliability duty), up to 200 kW<\/td>\n                    <td>\u2264 4.0<\/td>\n                    <td>&gt; 6.6<\/td>\n                <\/tr>\n                <tr>\n                    <td>Category I (high-reliability duty), over 200 kW<\/td>\n                    <td>\u2264 5.0<\/td>\n                    <td>&gt; 7.6<\/td>\n                <\/tr>\n                <tr>\n                    <td>Category II (general duty), up to 200 kW<\/td>\n                    <td>\u2264 5.1<\/td>\n                    <td>&gt; 8.5<\/td>\n                <\/tr>\n                <tr>\n                    <td>Category II (general duty), over 200 kW<\/td>\n                    <td>\u2264 6.1<\/td>\n                    <td>&gt; 9.5<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n        \n        <div class=\"info-box\">\n            <strong>Nota:<\/strong> These values are the evaluation-zone limits of ISO&nbsp;10816-7 (Table&nbsp;A.1) for rotodynamic pumps with power above 1&nbsp;kW. Vibration at or below the zone&nbsp;B limit is considered acceptable for unrestricted long-term operation; values above the zone&nbsp;C\/D boundary indicate a risk of damage. Newly commissioned pumps normally fall within zone&nbsp;A (\u2264&nbsp;2.5\u20134.2&nbsp;mm\/s depending on category and power).\n        <\/div>\n        \n        <h3>Signos de un balanceo exitoso<\/h3>\n        <ul>\n            <li>70\u201390% reduction in vibration at the 1\u00d7 rotational frequency<\/li>\n            <li>Stable and consistent vibration phase readings<\/li>\n            <li>Absence of unusual noise<\/li>\n            <li>Smooth, uniform pump operation<\/li>\n        <\/ul>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>6. Recomendaciones pr\u00e1cticas<\/h2>\n        \n        <h3>Frecuencia de balanceo<\/h3>\n        \n        <div class=\"tech-specs\">\n            <div class=\"spec-card\">\n                <h4>Balanceo programado<\/h4>\n                <ul>\n                    <li>New equipment \u2013 after initial run-in period<\/li>\n                    <li>After major repairs \u2013 mandatory<\/li>\n                    <li>Anualmente para equipo cr\u00edtico<\/li>\n                    <li>When vibration levels double from baseline<\/li>\n                <\/ul>\n            <\/div>\n            \n            <div class=\"spec-card\">\n                <h4>Balanceo no programado<\/h4>\n                <ul>\n                    <li>Upon noticing unusual vibration or noise<\/li>\n                    <li>After any impeller replacement<\/li>\n                    <li>If vibration exceeds acceptable levels<\/li>\n                    <li>After an emergency shutdown<\/li>\n                <\/ul>\n            <\/div>\n        <\/div>\n        \n        <h3>Requisitos para un balanceo de calidad<\/h3>\n        <ul>\n            <li>Ensure the pump is in good mechanical condition<\/li>\n            <li>Verify the pump is firmly mounted on a stable foundation<\/li>\n            <li>Check that bearings have no excessive play<\/li>\n            <li>Confirm proper alignment between pump and driver<\/li>\n            <li>Maintain stable operating speed during balancing<\/li>\n        <\/ul>\n        \n        <div class=\"warning-box\">\n            <strong>Atenci\u00f3n:<\/strong> Balancing will not eliminate vibration caused by issues such as bearing wear, shaft misalignment, coupling defects, or other mechanical faults. Address those problems separately.\n        <\/div>\n        \n        <h3>Documentaci\u00f3n de resultados<\/h3>\n        <ul>\n            <li>Keep a log of all balancing work performed<\/li>\n            <li>Save the Balanset-1A software reports for each balance job<\/li>\n            <li>Document the mass and position of installed correction weights<\/li>\n            <li>Record the final vibration levels after balancing (control measurements)<\/li>\n        <\/ul>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>Conclusi\u00f3n<\/h2>\n        \n        <p>The portable Balanset-1A device provides effective balancing of hydraulic pumps directly at the workplace. Proper application of this technology allows users to:<\/p>\n        \n        <ul>\n            <li>Reduce equipment vibration by a factor of 3\u201310<\/li>\n            <li>Increase bearing service life by 2\u20135 times<\/li>\n            <li>Lower energy consumption by 5\u201315%<\/li>\n            <li>Prevent emergency breakdowns<\/li>\n            <li>Decrease overall maintenance costs<\/li>\n        <\/ul>\n        \n        <p>Regular balancing of hydraulic pumps is an important part of the planned preventive maintenance system for industrial equipment.<\/p>\n        \n        <div class=\"info-box\">\n            <strong>Soporte t\u00e9cnico:<\/strong> For any questions about using the Balanset-1A device, please <a href=\"mailto:info@vibromera.com\">contact Vibromera company specialists<\/a>.\n        <\/div>\n    <\/div>\n\n    <div class=\"section\">\n        <h2>Preguntas frecuentes (FAQ)<\/h2>\n        <h3>What is hydraulic pump balancing?<\/h3>\n        <p>Hydraulic pump balancing is the process of correcting the uneven distribution of mass in a pump&rsquo;s rotating components (such as the impeller and shaft). By adding or removing small weights, the goal is to eliminate excessive vibration and noise, improving performance and extending the pump&rsquo;s service life.<\/p>\n        <h3>Why is balancing a hydraulic pump important?<\/h3>\n        <p>Balancing a pump is crucial because an imbalanced pump can cause excessive vibration and noise, leading to accelerated wear of bearings and seals, reduced efficiency, and an increased risk of sudden failure. Proper balancing helps ensure smooth, efficient, and reliable pump operation.<\/p>\n        <h3>How do you balance a hydraulic pump?<\/h3>\n        <p>Hydraulic pump balancing is typically done by using a device like the Balanset-1A. The process involves measuring the pump&rsquo;s vibration and phase, adding a trial weight to the rotor, measuring the change, and then calculating and installing a correction weight at a specific location. After installing the correction weight, the pump is run again to verify that vibration levels have dropped to acceptable limits.<\/p>\n        <h3>What equipment is used for pump balancing?<\/h3>\n        <p>Pump balancing requires a vibration measurement and balancing system. The Balanset-1A kit, for example, includes a USB interface module, two vibration sensors (accelerometers), a laser tachometer (phase reference sensor), reflective tape for the rotor, electronic scales for weighing trial and correction weights, and specialized software running on a laptop to guide the balancing procedure.<\/p>\n        <h3>How often should a pump be balanced?<\/h3>\n        <p>Pumps should be balanced whenever there is significant vibration or after events that could cause imbalance. It&rsquo;s recommended to balance new pumps after an initial run-in period, after major repairs or impeller replacements, and as part of annual maintenance for critical pumps. Unscheduled balancing is advised if unusual vibration or noise appears or after any emergency shutdown.<\/p>\n        <h3>What are acceptable vibration levels for a balanced pump?<\/h3>\n        <p>Acceptable vibration levels depend on the pump category and power. ISO&nbsp;10816-7 (rotodynamic pumps above 1&nbsp;kW) sets zone&nbsp;B limits \u2014 acceptable for unrestricted long-term operation \u2014 of 4.0&nbsp;mm\/s (RMS) for Category&nbsp;I (high-reliability) pumps up to 200&nbsp;kW and 5.0&nbsp;mm\/s above 200&nbsp;kW; for general-duty Category&nbsp;II pumps the limits are 5.1&nbsp;mm\/s up to 200&nbsp;kW and 6.1&nbsp;mm\/s above 200&nbsp;kW. Vibration above the zone&nbsp;C\/D boundary (6.6\u20139.5&nbsp;mm\/s depending on category and power) indicates a risk of damage and needs immediate attention.<\/p>\n        <h3>Does balancing fix all vibration issues?<\/h3>\n        <p>No. Balancing addresses vibration caused by rotor mass imbalance. It will significantly reduce vibrations at the rotational frequency, but it cannot fix other sources of vibration such as misalignment, worn bearings, bent shafts, or other mechanical problems. Those issues must be diagnosed and repaired separately.<\/p>\n    <\/div>\n<\/body>\n<\/html>\n<\/div><\/div><div id=\"panel-1204-0-0-2\" class=\"so-panel widget widget_sow-image panel-last-child\" data-index=\"2\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1204\"\n\t\t\t\n\t\t>\n<div class=\"sow-image-container\">\n\t\t<img \n\tsrc=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/08\/image105.webp\" width=\"640\" height=\"415\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/08\/image105.webp 640w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/08\/image105-600x389.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/08\/image105-300x195.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/08\/image105-18x12.webp 18w\" sizes=\"(max-width: 640px) 100vw, 640px\" title=\"Software para el balancero port\u00e1til y analizador de vibraciones Balanset-1A. Modo vibr\u00f3metro.\" alt=\"Software para el balancero port\u00e1til y analizador de vibraciones Balanset-1A. Modo vibr\u00f3metro.\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Products Portable balancer &amp; Vibration analyzer Balanset-1A &euro;1,975.00 + VAT (if applicable) Dynamic balancer \u201cBalanset-1A\u201d OEM &euro;1,735.00 + VAT (if applicable) Vibration sensor &euro;90.00 + VAT (if applicable) Optical Sensor (Laser Tachometer) &euro;124.00 + VAT (if applicable) Balanset-4 &euro;6,803.00 + VAT (if applicable) Hydraulic Pump Balancing Using Balanset-1A Device Hydraulic [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":924,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ai_generated_summary":"","footnotes":""},"categories":[4,9,5],"tags":[],"class_list":["post-1204","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-example","category-rotors","category-solutions"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/posts\/1204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/comments?post=1204"}],"version-history":[{"count":4,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/posts\/1204\/revisions"}],"predecessor-version":[{"id":102073,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/posts\/1204\/revisions\/102073"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/media\/924"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/media?parent=1204"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/categories?post=1204"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vibromera.eu\/es-mx\/wp-json\/wp\/v2\/tags?post=1204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}