{"id":101571,"date":"2026-05-30T21:40:59","date_gmt":"2026-05-30T21:40:59","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101571"},"modified":"2026-07-02T18:41:59","modified_gmt":"2026-07-02T18:41:59","slug":"axial-fans","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/es\/balancing-catalog\/axial-fans\/","title":{"rendered":"Equilibrado de ventiladores axiales"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/es\/balancing-catalog\/\">Servicios de equilibrado<\/a> \u203a <a href=\"https:\/\/vibromera.eu\/es\/balancing-catalog\/fans\/\">Ventiladores<\/a> &rsaquo; Ventiladores axiales<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Equilibrado de ventiladores axiales &mdash; In situ, a velocidad de funcionamiento<\/h1>\n<p class=\"lede\">Los ventiladores axiales de paletas, axiales tubulares y de flujo axial de gran tama\u00f1o desarrollan vibraciones en el momento en que la erosi\u00f3n de las paletas, la acumulaci\u00f3n de suciedad o una reparaci\u00f3n modifican su distribuci\u00f3n de masas. Equilibramos rotores de ventiladores axiales <strong>in situ, a velocidad de marcha<\/strong> &mdash; sin retirada del conducto, sin desmontaje del rotor &mdash; eliminando la causa principal de los fallos de los rodamientos, el rozamiento de las puntas de las palas y la fatiga estructural en una sola sesi\u00f3n in situ.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/es\/balanset-1a\/\">Obtener el Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/es\/community\/\">Pregunte a nuestro ingeniero<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2017\/12\/20131113_130218-768x1024.webp\" alt=\"Rotor de ventilador axial equilibrado in situ a velocidad de funcionamiento dentro del conducto\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Resumiendo:<\/b> El equilibrado de ventiladores axiales se realiza in situ, con el rotor funcionando a velocidad normal dentro del conducto, utilizando el m\u00e9todo de coeficiente de influencia. Un aceler\u00f3metro de vibraciones en el alojamiento del cojinete y un tac\u00f3metro l\u00e1ser en el eje miden el estado de desequilibrio; el Balanset-1A calcula la masa de correcci\u00f3n exacta y la posici\u00f3n angular. Sin desmontar el rotor, sin transporte: un trabajo t\u00edpico se completa en menos de una hora, reduciendo las vibraciones en 70 % o m\u00e1s, cumpliendo los grados de equilibrado ISO 14694 \/ ISO 21940-11 y multiplicando la vida \u00fatil de los rodamientos por un factor de ocho o m\u00e1s.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#signs\">S\u00edntomas<\/a><br \/>\n<a href=\"#why\">Causas y costes<\/a><br \/>\n<a href=\"#how\">Paso a paso<\/a><br \/>\n<a href=\"#what\">Lo que equilibramos<\/a><br \/>\n<a href=\"#standards\">Normas<\/a><br \/>\n<a href=\"#device\">El Balanset-1A<\/a><br \/>\n<a href=\"#compare\">Campo frente a m\u00e1quina<\/a><br \/>\n<a href=\"#cases\">Casos reales<\/a><br \/>\n<a href=\"#calc\">Calculadoras<\/a><br \/>\n<a href=\"#faq\">PREGUNTAS FRECUENTES<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"signs\">\n<h2>Signos de que su ventilador axial est\u00e1 desequilibrado<\/h2>\n<p>El desequilibrio axial del ventilador se revela a trav\u00e9s de un conjunto caracter\u00edstico de s\u00edntomas que empeoran progresivamente si se ignoran:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Fuerte vibraci\u00f3n 1\u00d7 RPM<\/b> Un componente dominante una vez por revoluci\u00f3n en el espectro de vibraci\u00f3n es el indicador m\u00e1s claro de desequilibrio de la masa del rotor, confirmado instant\u00e1neamente por la pantalla FFT del Balanset-1A.<\/div>\n<div><b>Pulsaci\u00f3n del flujo de aire en los conductos<\/b> Un anillo de aspas desequilibrado crea un empuje asim\u00e9trico, provocando fluctuaciones de presi\u00f3n que ondulan a trav\u00e9s de los conductos conectados y se sienten como sacudidas r\u00edtmicas.<\/div>\n<div><b>Fallo r\u00e1pido de los rodamientos<\/b> Las cargas centr\u00edfugas rotativas del desequilibrio se superponen a las cargas aerodin\u00e1micas, reduciendo la vida L<sub>10<\/sub> a una fracci\u00f3n de su valor nominal.<\/div>\n<div><b>Roce de la punta del \u00e1labe<\/b> La desviaci\u00f3n lateral del eje provocada por el desequilibrio acerca las puntas de las palas al anillo de la cubierta, provocando contacto intermitente, ruido y da\u00f1os en las palas.<\/div>\n<div><b>Aflojamiento del perno de cimentaci\u00f3n<\/b> Las sacudidas c\u00edclicas fatigan las roscas y los soportes antivibraci\u00f3n, lo que permite que las fijaciones retrocedan durante el funcionamiento normal.<\/div>\n<div><b>Corriente del motor elevada<\/b> La vibraci\u00f3n mec\u00e1nica se retroalimenta como carga variable en el motor de accionamiento, lo que aumenta el consumo de corriente y energ\u00eda y la temperatura del motor.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"why\">\n<h2>Por qu\u00e9 los ventiladores axiales pierden el equilibrio y cu\u00e1nto cuesta<\/h2>\n<p>Un ventilador axial sale de f\u00e1brica dentro de las tolerancias de equilibrio, pero el servicio de campo altera r\u00e1pidamente ese equilibrio. Las part\u00edculas abrasivas de la corriente de aire erosionan los bordes de ataque de los \u00e1labes de forma desigual; el polvo y el material fibroso se acumulan en la cara de presi\u00f3n de algunos \u00e1labes mientras que otros quedan limpios; la corrosi\u00f3n pica los bordes de salida de forma asim\u00e9trica; y las sustituciones de \u00e1labes o las reparaciones de soldaduras a\u00f1aden masa localizada en un lado del buje. Dado que la fuerza centr\u00edfuga es proporcional al <em>cuadrado<\/em> de velocidad de rotaci\u00f3n, incluso un desplazamiento de 20 g en la punta del \u00e1labe genera cientos de newtons de fuerza din\u00e1mica a las velocidades t\u00edpicas de los ventiladores, mucho m\u00e1s de lo que el rodamiento fue dise\u00f1ado para absorber como carga radial adicional.<\/p>\n<p>Las consecuencias econ\u00f3micas se acumulan r\u00e1pidamente: sustituci\u00f3n de rodamientos y juntas laber\u00ednticas, mano de obra de emergencia durante paradas imprevistas, reducci\u00f3n de la eficiencia del ventilador por cambios en la holgura de las puntas de las aspas y, finalmente, fatiga estructural en la estructura de acero de soporte. Una sola sesi\u00f3n de equilibrado in situ, normalmente de menos de una hora, elimina la fuerza din\u00e1mica en su origen en lugar de tratar repetidamente sus s\u00edntomas posteriores.<\/p>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>\u00d710<\/b><span>vida \u00fatil de los rodamientos cuando las vibraciones se reducen a la mitad<\/span><\/div>\n<div class=\"vbm-stat\"><b>-70%<\/b><span>descenso t\u00edpico de las vibraciones tras una sesi\u00f3n<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>planos corregidos en una visita<\/span><\/div>\n<div class=\"vbm-stat\"><b>&lt;1h<\/b><span>trabajo t\u00edpico in situ<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Por qu\u00e9 reducir a la mitad las vibraciones multiplica la vida \u00fatil de los rodamientos<\/h2>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> define la vida nominal de un rodamiento como <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b>, donde P es la carga din\u00e1mica soportada por el rodamiento y el exponente p = 3 para los rodamientos de bolas y 10\/3 para los rodamientos de rodillos. Desequilibrio residual <em>es<\/em> que la carga radial giratoria P, y la amplitud de vibraci\u00f3n la sigue directamente - por lo que reducir la vibraci\u00f3n a la mitad reduce P a la mitad y multiplica la vida del rodamiento por 2<sup>p<\/sup>: sobre <b>8\u00d7 para rodamientos de bolas y ~10\u00d7 para rodamientos de rodillos<\/b> (2<sup>10\/3<\/sup>&nbsp;\u2248 10). Ejecute sus propios n\u00fameros en nuestro <a href=\"https:\/\/vibromera.eu\/es\/calculators\/bearing-load\/\">calculadora de vida \u00fatil de los rodamientos<\/a>.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>C\u00f3mo equilibramos un ventilador axial &mdash; paso a paso<\/h2>\n<p>El equilibrado de campo con la Balanset-1A sigue el m\u00e9todo del coeficiente de influencia, el mismo procedimiento sistem\u00e1tico que puede realizar usted mismo in situ, sin necesidad de conocimientos previos de la geometr\u00eda del rotor:<\/p>\n<ol class=\"vbm-steps\">\n<li><b>Instale los sensores.<\/b> Se fija un aceler\u00f3metro de vibraciones a la carcasa de los cojinetes del ventilador y se apunta un tac\u00f3metro l\u00e1ser a una banda reflectante en el eje o el cubo. El ventilador sigue funcionando en condiciones normales, sin necesidad de desmontarlo.<\/li>\n<li><b>Mide la l\u00ednea de base.<\/b> Una marcha a plena velocidad de funcionamiento registra la amplitud de la vibraci\u00f3n y el \u00e1ngulo de fase a 1\u00d7 RPM, estableciendo el estado de desequilibrio actual en magnitud y direcci\u00f3n.<\/li>\n<li><b>A\u00f1ade un peso de prueba.<\/b> Una peque\u00f1a masa de prueba de peso conocido se sujeta al anillo de la pala, al disco del buje o a la ra\u00edz de la pala en una posici\u00f3n angular registrada. Una segunda pasada muestra c\u00f3mo responde el rotor a una masa espec\u00edfica en ese lugar: el coeficiente de influencia.<\/li>\n<li><b>Deja que el aparato calcule.<\/b> El Balanset-1A aplica el algoritmo de coeficiente de influencia para calcular la masa de correcci\u00f3n exacta y la colocaci\u00f3n angular: un solo plano para rotores estrechos, dos planos para anillos de palas anchos, grandes ventiladores de t\u00fanel o configuraciones de cubo y punta en las que el desequilibrio se distribuye a lo largo del eje del rotor.<\/li>\n<li><b>Ajustar el peso corrector.<\/b> Soldar, atornillar o sujetar la masa calculada en la posici\u00f3n indicada en el disco del cubo, la ra\u00edz de la pala o el anillo de equilibrado. El peso de prueba se retira a menos que forme parte de la soluci\u00f3n.<\/li>\n<li><b>Verificar y documentar.<\/b> Una medici\u00f3n final confirma que el desequilibrio residual se encuentra dentro de la banda de tolerancia ISO para el grado de equilibrado del ventilador. El Balanset-1A genera un informe de equilibrado para los registros de mantenimiento y la documentaci\u00f3n de conformidad.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"what\">\n<h2>Lo que equilibramos<\/h2>\n<ul class=\"vbm-list\">\n<li>Ventiladores axiales de paletas (canalizados, con paletas gu\u00eda)<\/li>\n<li>Ventiladores tubo-axiales (h\u00e9lice en carcasa cil\u00edndrica)<\/li>\n<li>Grandes ventiladores axiales (ventilaci\u00f3n de minas, t\u00faneles)<\/li>\n<li>Ventiladores de caldera de tiro forzado (FD) y tiro inducido (ID)<\/li>\n<li>Ventiladores de h\u00e9lice de la torre de refrigeraci\u00f3n<\/li>\n<li>Ventiladores de extracci\u00f3n de techo<\/li>\n<li>Ventiladores axiales de extracci\u00f3n de humos y resistentes al fuego<\/li>\n<li>Ventiladores axiales reversibles con \u00e1labes de paso variable<\/li>\n<li>Ventiladores para secado de grano agr\u00edcola<\/li>\n<li>Peque\u00f1os ventiladores axiales en l\u00ednea montados en conducto<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Tolerancias y normas<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 14694<\/b> especifica la calidad de equilibrado y los l\u00edmites de vibraci\u00f3n para ventiladores industriales, definiendo el desequilibrio residual admisible por categor\u00eda de aplicaci\u00f3n del ventilador (BV-1 a BV-5). Las tolerancias de calidad de equilibrado subyacentes se definen en <b>ISO 21940-11<\/b> (sucesora de la norma ISO 1940-1). La mayor\u00eda de los ventiladores axiales industriales pertenecen a categor\u00edas en las que <b>G6.3<\/b> es el grado m\u00ednimo aceptable; los ventiladores que manipulan aire de proceso cr\u00edtico, que manipulan vapores inflamables o que funcionan a velocidades de punta elevadas deben cumplir normalmente los requisitos de <b>G2.5 o superior<\/b>.<\/p>\n<p>Equilibramos seg\u00fan el grado que exija su categor\u00eda de ventilador y suministramos cifras documentadas de desequilibrio residual, en g-mm a la velocidad de funcionamiento medida, para sus registros de mantenimiento y conformidad. Utilice nuestro <a href=\"https:\/\/vibromera.eu\/es\/calculators\/residual-unbalance-iso1940\/\">calculadora de desequilibrio residual<\/a> para conocer su tolerancia admisible antes de empezar.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A: su kit completo de equilibrado de campo<\/h2>\n<p>Todo lo que aparece en esta p\u00e1gina se hace con un instrumento port\u00e1til: el <a href=\"https:\/\/vibromera.eu\/es\/balanset-1a\/\">Balanset-1A<\/a>. Es un equilibrador din\u00e1mico de dos canales y un analizador de vibraciones que equilibra rotores de ventiladores axiales <strong>en sus propios cojinetes, a velocidad de funcionamiento, dentro del conducto<\/strong>, utilizando el m\u00e9todo del coeficiente de influencia de 3 pasadas: el software calcula la masa y el \u00e1ngulo de correcci\u00f3n exactos y guarda un informe.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Kit completo de equilibrado Balanset-1A con sensores, tac\u00f3metro l\u00e1ser, b\u00e1scula y malet\u00edn\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Contenido del kit completo<\/h3>\n<p class=\"price\">\u20ac1,975 <span>&middot; Kit completo, en stock, factura con IVA<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Unidad de medici\u00f3n de interfaz (USB, 2 canales)<\/li>\n<li>Dos aceler\u00f3metros de vibraciones (cable de 4 m, 10 m opcional)<\/li>\n<li>Tac\u00f3metro l\u00e1ser \/ sensor \u00f3ptico de fase (50-500 mm)<\/li>\n<li>Soporte magn\u00e9tico para el sensor<\/li>\n<li>Balanza digital para pesos de prueba y correcci\u00f3n<\/li>\n<li>Software de equilibrado y an\u00e1lisis para Windows<\/li>\n<li>Maleta de transporte de pl\u00e1stico<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/es\/balanset-1a\/\">Ver el Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/es\/community\/\">Pregunte a nuestro ingeniero<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Recomendado<\/span><\/p>\n<h3>Kit completo<\/h3>\n<p>Unidad \u00b7 2 sensores \u00b7 tac\u00f3metro l\u00e1ser \u00b7 soporte magn\u00e9tico \u00b7 balanza digital \u00b7 software \u00b7 malet\u00edn de transporte. Todo lo necesario para empezar a equilibrar nada m\u00e1s sacarlo de la caja.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">Fabricante de equipos originales (OEM)<\/span><\/p>\n<h3>Juego OEM<\/h3>\n<p>Unidad &middot; 2 sensores &middot; tac\u00f3metro l\u00e1ser &middot; software. Para integradores que ya disponen de soporte, b\u00e1scula y malet\u00edn, o que integran la unidad en una equilibradora.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Principales especificaciones t\u00e9cnicas<\/caption>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Valor<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Canales de medici\u00f3n<\/td>\n<td>2 (equilibrado en uno y dos planos)<\/td>\n<\/tr>\n<tr>\n<td>Rango de velocidad de vibraci\u00f3n<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Rango de frecuencia<\/td>\n<td>5&ndash;1000 Hz (&le;10% de error de amplitud por encima de 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>Precisi\u00f3n de la medici\u00f3n<\/td>\n<td>\u00b15% del fondo de escala<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo<\/td>\n<td>Coeficiente de influencia con 3 mediciones (1 o 2 planos)<\/td>\n<\/tr>\n<tr>\n<td>An\u00e1lisis<\/td>\n<td>Amplitud y fase a 1\u00d7, espectro FFT y forma de onda, informes guardados<\/td>\n<\/tr>\n<tr>\n<td>Computadora port\u00e1til<\/td>\n<td>No incluido (PC con Windows, disponible previa solicitud)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>\u2713<\/b> En stock<\/span><span><b>\u2713<\/b> DHL Portugal 35 \u20ac<\/span><span><b>\u2713<\/b> DHL en todo el mundo 110 \u20ac<\/span><span><b>\u2713<\/b> 2 a\u00f1os de garant\u00eda<\/span><span><b>\u2713<\/b> Factura IVA<\/span><span><b>\u2713<\/b> Asistencia t\u00e9cnica<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"compare\">\n<h2>Equilibrado de campo frente a m\u00e1quina equilibradora: \u00bfcu\u00e1l es la m\u00e1s adecuada para su ventilador?<\/h2>\n<table class=\"vbm-table\">\n<caption>Comparaci\u00f3n: equilibrado in situ frente a m\u00e1quina equilibradora espec\u00edfica<\/caption>\n<thead>\n<tr>\n<th>Factor<\/th>\n<th>Equilibrado de campo (Balanset-1A)<\/th>\n<th>Equilibradora (taller)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u00bfSe ha retirado el ventilador del conducto?<\/td>\n<td class=\"yes\">No \u2014 funciona en su sitio<\/td>\n<td class=\"no\">S\u00ed &mdash; requiere desmontaje completo<\/td>\n<\/tr>\n<tr>\n<td>\u00bfDesmontaje del rotor?<\/td>\n<td class=\"yes\">No<\/td>\n<td class=\"no\">S\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Parada de producci\u00f3n<\/td>\n<td>S\u00f3lo instalaci\u00f3n del sensor (&lt;15 min)<\/td>\n<td>De horas a d\u00edas (tirar, transportar, equilibrar, reinstalar)<\/td>\n<\/tr>\n<tr>\n<td>Velocidad de equilibrado<\/td>\n<td>Velocidad real de funcionamiento y caudal de aire<\/td>\n<td>Husillo independiente de baja velocidad<\/td>\n<\/tr>\n<tr>\n<td>Tiene en cuenta la flexi\u00f3n del eje y los acoplamientos<\/td>\n<td class=\"yes\">S\u00ed - montaje completo equilibrado in situ<\/td>\n<td class=\"no\">S\u00f3lo rotor, sin efectos de instalaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Palas de paso variable<\/td>\n<td class=\"yes\">Equilibrado al paso de funcionamiento elegido<\/td>\n<td class=\"no\">S\u00f3lo paso fijo<\/td>\n<\/tr>\n<tr>\n<td>Normas cumplidas<\/td>\n<td>ISO 14694, ISO 21940-11<\/td>\n<td>ISO 21940-11<\/td>\n<\/tr>\n<tr>\n<td>Coste del equipo<\/td>\n<td>1.975 euros (kit completo)<\/td>\n<td>10.000 \u20ac - 50.000 \u20ac+<\/td>\n<\/tr>\n<tr>\n<td>Tiempo t\u00edpico de trabajo<\/td>\n<td>&lt;1 hora in situ<\/td>\n<td>1-3 d\u00edas en total<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>El equilibrado en campo es la opci\u00f3n preferida siempre que el ventilador pueda funcionar y el rotor cumpla el criterio de rotor r\u00edgido (velocidad de funcionamiento muy por debajo de la primera velocidad cr\u00edtica). Una equilibradora de taller sigue siendo adecuada para rotores de nueva construcci\u00f3n con tiempo de funcionamiento nulo, o para rotores muy grandes que requieran un desmontaje completo para inspeccionar o sustituir las palas.<\/p>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Casos reales de equilibrado de ventiladores axiales<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/es\/ejemplo\/ventiladores-balanceo\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2017\/12\/20131113_130218-768x1024.webp\" alt=\"Equilibrado de campo de rotores de ventiladores axiales de \u00e1labes (vane-axial) y axiales tubulares (tube-axial) con Balanset-1A\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Ventiladores axiales y de paletas<\/h3>\n<p>Equilibrado de campo de rotores de ventiladores axiales y de paletas axiales en entornos industriales, con resultados documentados de desequilibrio residual.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/es\/ejemplo\/equilibrar-el-ventilador-de-escape\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2017\/12\/IMG_20170828_140450-1024x576.webp\" alt=\"Ventilador axial de escape equilibrado in situ a velocidad de funcionamiento\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Extractor de aire in situ<\/h3>\n<p>Equilibrado monoplano in situ de un ventilador de extracci\u00f3n a velocidad de funcionamiento utilizando la Balanset-1A, la vibraci\u00f3n se redujo en m\u00e1s de 75 %.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/es\/ejemplo\/impulsores-de-ventilador-de-equilibrado-2\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/03\/IMG_20171228_131923-1024x768.webp\" alt=\"Procedimiento de equilibrado del impulsor de un ventilador axial HVAC paso a paso\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Gu\u00eda paso a paso del ventilador HVAC<\/h3>\n<p>Procedimiento completo de equilibrado en dos planos para impulsores de ventilador axial HVAC, con instrucciones de colocaci\u00f3n de sensores y fijaci\u00f3n de pesos.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Calculadoras de ventiladores axiales gratuitas<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/es\/calculators\/blade-pass-frequency\/\">Frecuencia de paso de las palas<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/calculators\/fan-blade-centrifugal-force\/\">Fuerza centr\u00edfuga de los \u00e1labes del ventilador<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/calculators\/fan-shaft-power\/\">Potencia del eje del ventilador<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/calculators\/residual-unbalance-iso1940\/\">Desequilibrio residual (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/calculators\/trial-weight-calculator\/\">Calculadora de masa de prueba<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/calculators\/bearing-load\/\">Calculadora de vida \u00fatil de rodamientos<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>Equilibrado de ventiladores axiales FAQ<\/h2>\n<details>\n<summary>\u00bfSe puede equilibrar un ventilador axial sin desmontarlo del conducto?<\/summary>\n<div class=\"ans\">S\u00ed, esto es exactamente lo que se consigue con el equilibrado in situ. El rotor permanece en sus propios cojinetes dentro del conducto y se equilibra a su velocidad de funcionamiento y caudal de aire reales. No es necesario desmontarlo, transportarlo ni equilibrarlo en un taller independiente, lo que reduce al m\u00ednimo el tiempo de inactividad y elimina el riesgo de reintroducir la desalineaci\u00f3n de la instalaci\u00f3n despu\u00e9s de volver a montarla.<\/div>\n<\/details>\n<details>\n<summary>\u00bfC\u00f3mo puedo saber si la vibraci\u00f3n se debe al desequilibrio y no a otro fallo?<\/summary>\n<div class=\"ans\">El desequilibrio produce un componente de vibraci\u00f3n dominante exactamente a 1\u00d7 la frecuencia de funcionamiento (1\u00d7 RPM). Si el pico m\u00e1s fuerte del espectro est\u00e1 en 1\u00d7 y su \u00e1ngulo de fase gira de forma sincr\u00f3nica con el eje, la causa probable es el desequilibrio. Otros fallos (defectos en los rodamientos, desalineaci\u00f3n, resonancia de las palas) producen patrones de frecuencia diferentes. El Balanset-1A muestra tanto la amplitud como la fase en 1\u00d7 y el espectro FFT completo, ayud\u00e1ndole a confirmar el diagn\u00f3stico antes de a\u00f1adir cualquier peso de correcci\u00f3n.<\/div>\n<\/details>\n<details>\n<summary>\u00bfNecesitan un tratamiento especial los ventiladores axiales de paso variable?<\/summary>\n<div class=\"ans\">El procedimiento de equilibrado del coeficiente de influencia es el mismo, pero debe realizarse en el \u00e1ngulo de inclinaci\u00f3n de funcionamiento m\u00e1s com\u00fan, ya que el desplazamiento de las palas desplaza su centro de masa con respecto al cubo. Si el ventilador funciona habitualmente en una amplia gama de pasos, lo m\u00e1s pr\u00e1ctico es equilibrarlo en el paso medio y verificar la vibraci\u00f3n en los extremos. Repita el procedimiento si el ajuste del paso cambia significativamente durante una renovaci\u00f3n.<\/div>\n<\/details>\n<details>\n<summary>\u00bfQu\u00e9 grado de equilibrado ISO se aplica a los ventiladores axiales?<\/summary>\n<div class=\"ans\">La norma ISO 14694 agrupa los ventiladores por categor\u00eda de aplicaci\u00f3n (BV-1 a BV-5). La mayor\u00eda de los ventiladores axiales industriales deben cumplir un m\u00ednimo de G6.3; los ventiladores en aplicaciones de aire limpio, proceso o contra incendios suelen requerir G2.5 o superior. El Balanset-1A calcula el desequilibrio residual alcanzado en g-mm y lo compara con el l\u00edmite de grado ISO 21940-11 para la masa y velocidad de su rotor; a continuaci\u00f3n, guarda la cifra en un informe imprimible.<\/div>\n<\/details>\n<details>\n<summary>\u00bfUn plano o dos para un ventilador axial?<\/summary>\n<div class=\"ans\">Los ventiladores de h\u00e9lice de cubo estrecho y los peque\u00f1os ventiladores de conducto con una profundidad axial corta en relaci\u00f3n con su di\u00e1metro se corrigen normalmente en un solo plano. Los anillos de \u00e1labes anchos, los ventiladores de t\u00fanel de gran di\u00e1metro y los rotores en los que los \u00e1labes est\u00e1n repartidos a lo largo de una longitud axial significativa necesitan un equilibrado en dos planos (din\u00e1mico) porque el desequilibrio se distribuye a lo largo del eje del rotor. El Balanset-1A gestiona ambos modos con el mismo hardware: seleccione el recuento de planos de correcci\u00f3n en el software antes de la ejecuci\u00f3n de la medici\u00f3n de referencia.<\/div>\n<\/details>\n<details>\n<summary>\u00bfPodemos hacer el equilibrado nosotros mismos con el Balanset-1A?<\/summary>\n<div class=\"ans\">S\u00ed, el Balanset-1A est\u00e1 dise\u00f1ado para que los equipos de mantenimiento puedan utilizarlo sin necesidad de formaci\u00f3n especializada. El software le gu\u00eda a trav\u00e9s de cada medici\u00f3n en pantalla, calcula la masa de correcci\u00f3n y el \u00e1ngulo autom\u00e1ticamente y genera un informe de resultados. Nuestro foro comunitario est\u00e1 a su disposici\u00f3n si se encuentra con una configuraci\u00f3n de rotor inusual o desea verificar su enfoque antes de ajustar el peso de correcci\u00f3n.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Aprender la teor\u00eda<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/axial-fan-defects\/\">Defectos del ventilador axial<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/fan-defects\/\">Defectos del ventilador<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/blade-resonance\/\">Resonancia de \u00e1labes<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/equilibrado-del-campo\/\">Equilibrado en campo<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/balance-quality\/\">Grados de calidad de equilibrado<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/residual-unbalance\/\">Desequilibrio residual<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/es\/glossary\/dynamic-balancing\/\">Equilibrado din\u00e1mico<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Equilibre hoy mismo su ventilador axial<\/h2>\n<p>El Balanset-1A le gu\u00eda a trav\u00e9s del equilibrado de ventiladores axiales de uno y dos planos a velocidad de funcionamiento, dentro del conducto, calcula el peso y el \u00e1ngulo de correcci\u00f3n exactos y documenta el desequilibrio residual conseguido seg\u00fan ISO 14694 e ISO 21940-11. Sin desmontaje del rotor, sin p\u00e9rdida de producci\u00f3n: s\u00f3lo un ventilador m\u00e1s silencioso y duradero.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/es\/balanset-1a\/\">Ver el Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/es\/community\/\">Hacer una pregunta en el foro<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Fans &rsaquo; Axial Fans Axial Fan Balancing &mdash; In-Situ, at Operating Speed Vane-axial, tube-axial and large axial-flow fans develop vibration the moment blade erosion, dirt build-up or a repair shifts their mass distribution. We balance axial fan rotors in situ, at running speed &mdash; no removal from [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101571","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/pages\/101571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/comments?post=101571"}],"version-history":[{"count":4,"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/pages\/101571\/revisions"}],"predecessor-version":[{"id":102059,"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/pages\/101571\/revisions\/102059"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/es\/wp-json\/wp\/v2\/media?parent=101571"}],"curies":[{"name":"gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}