{"id":101581,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101581"},"modified":"2026-07-02T19:11:15","modified_gmt":"2026-07-02T19:11:15","slug":"vibration-analyzer","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/et\/balancing-catalog\/vibration-analyzer\/","title":{"rendered":"Vibratsioonianal\u00fcsaator ja FFT spektri anal\u00fcsaator - Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/et\/balancing-catalog\/\">Tasakaalustamisteenused<\/a> ' Vibratsiooni anal\u00fcsaator<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Vibratsiooni anal\u00fcsaator - kahe kanaliga FFT spektri, faasi ja veadiagnostika<\/h1>\n<p class=\"lede\">Balanset-1A on kahe kanaliga vibratsioonianal\u00fcsaator, mis joonistab reaalajas FFT spektreid, m\u00f5\u00f5dab amplituudi ja faasi 1\u00d7 p\u00f6\u00f6rete arvu juures ning kaardistab vea signatuurid, et eristada tasakaalustamatust, valesuunalist paigutust, l\u00f5tvust ja laagrikahjustusi - seej\u00e4rel tasakaalustab samal seansil. \u00dcks kaasaskantav komplekt hinnaga 1 975 eurot katab diagnoosimise, parandamise ja kontrollimise ilma m\u00f5\u00f5teriistu vahetamata.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/et\/balanset-1a\/\">Hankige Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/et\/community\/\">K\u00fcsige meie insenerilt<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/02\/interface-1-e1518391488191.webp\" alt=\"Balanset-1A vibratsioonianal\u00fcsaatori FFT spektri liides s\u00fclearvutis\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>L\u00fchidalt:<\/b> The Balanset-1A vibratsioonianal\u00fcsaator captures simultaneous two-channel signals from its two vibratsiooniandurs (analog MEMS accelerometers), computes a reaalajas FFT spectrum, and displays amplitude and phase at every v\u00f5ll-order harmonic. Unbalance appears as a dominant 1&times; RPM peak; joondusviga as elevated 2&times; and 3&times; components; developed laager defects as BPFO\/BPFI peaks and sidebands; looseness as sub-harmonics. Because the same hardware and sensors are used for field balancing, you diagnose the fault, correct it, and verify the result in a single site visit &mdash; measuring vibratsioonikiirus from 0.2 to 80&nbsp;mm\/s across 5 to 1000&nbsp;Hz.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#when\">Millal anal\u00fc\u00fcsida<\/a><br \/>\n<a href=\"#measures\">Mida see m\u00f5\u00f5dab<\/a><br \/>\n<a href=\"#faults\">Vea diagnostika<\/a><br \/>\n<a href=\"#how\">Kuidas seda kasutada<\/a><br \/>\n<a href=\"#standards\">Standardid<\/a><br \/>\n<a href=\"#device\">Balanset-1A<\/a><br \/>\n<a href=\"#screenshots\">Ekraanipildid<\/a><br \/>\n<a href=\"#cases\">Reaalsed juhtumid<\/a><br \/>\n<a href=\"#calc\">Kalkulaatorid<\/a><br \/>\n<a href=\"#faq\">KKK<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"when\">\n<h2>M\u00e4rgid, et teie masin vajab vibratsioonianal\u00fc\u00fcsi, mitte ainult m\u00f5\u00f5teriista n\u00e4itu<\/h2>\n<p>\u00dcks \u00fcldine vibratsiooninumber \u00fctleb teile, et midagi on valesti. FFT-spekter \u00fctleb teile, mida ja miks. Need olukorrad n\u00f5uavad korralikku anal\u00fcsaatorit:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Tundmatu vibratsiooni p\u00f5hjus<\/b> \u00dcldine tase on k\u00f5rgenenud, kuid te ei saa \u00f6elda, kas s\u00fc\u00fcdlaseks on tasakaalustamatus, valesuunalisus, l\u00f5tvus v\u00f5i laagrikahjustus - FFT eraldab iga allkirja.<\/div>\n<div><b>Tugev 1\u00d7 RPM komponent<\/b> Domineeriv esimese astme tipp on rootorij\u00e4\u00e4kide tasakaalustamatuse \u00f5pikun\u00e4idiseks ja tasakaalustamise k\u00e4ivitajaks.<\/div>\n<div><b>K\u00f5rgendatud 2\u00d7 v\u00f5i 3\u00d7 harmoonilised signaalid<\/b> V\u00e4ljendunud teise v\u00f5i kolmanda astme komponent viitab tavaliselt haakeseadiste v\u00f5i v\u00f5llide nurga- v\u00f5i paralleelsele nihkele.<\/div>\n<div><b>Subharmoonilised v\u00f5i lairibam\u00fcra<\/b> Low-order laager defect frequencies (BPFO, BPFI, BSF, FTF) and their harmonics appear in the velocity spectrum as a defect develops &mdash; a warning worth trending before a breakdown, though the very earliest damage stage needs high-frequency envelope analysis.<\/div>\n<div><b>Remondij\u00e4rgne vastuv\u00f5tukontroll<\/b> P\u00e4rast tasakaalustamist, joondamist v\u00f5i laagrivahetust on vaja m\u00f5\u00f5detavat t\u00f5endit, et tase on langenud alla ISO 20816 aktsepteeritava piiri.<\/div>\n<div><b>Perioodiline seisundi j\u00e4relevalve uuring<\/b> Regulaarsete ajavahemike tagant baasspektrite salvestamine v\u00f5imaldab teil suundumusi t\u00f5usvatele amplituudidele ja planeerida hooldust\u00f6id enne planeerimata v\u00e4ljal\u00fclitamist.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"measures\">\n<h2>Mida Balanset-1A anal\u00fcsaator m\u00f5\u00f5dab<\/h2>\n<p>The analyzer captures simultaneous signals from the two supplied vibratsiooniandurs (analog MEMS accelerometers) referenced to the laser tachometer. Every parameter listed below is available in a single acquisition run:<\/p>\n<ul class=\"vbm-list\">\n<li>\u00dcldine vibratsioonikiirus (mm\/s RMS) ja kiirendus (m\/s\u00b2 v\u00f5i g)<\/li>\n<li>Reaalajas FFT-sagedusspekter kasutaja poolt valitava eraldusv\u00f5imega<\/li>\n<li>Vibratsiooni lainekuju (ajasignaal) m\u00f5lemal kanalil samaaegselt<\/li>\n<li>Faasinurk 1\u00d7 p\u00f6\u00f6rlemissageduse juures seoses v\u00f5lli taksomeetri v\u00f5rdlusn\u00e4itajaga<\/li>\n<li>1\u00d7, 2\u00d7, 3\u00d7 ja k\u00f5rgema j\u00e4rje amplituudid, mis on ekstraheeritud FFT-st.<\/li>\n<li>Samaaegne kahe kanaliga m\u00f5\u00f5tmine (m\u00f5lemad laagritasandid korraga)<\/li>\n<li>K\u00e4ivituskiirus (RPM) optilise lasertahomeetriga - nimesildi ei ole vaja.<\/li>\n<li>Vibratsioonitrendi logi j\u00e4rjestikuste m\u00f5\u00f5tmiste kohta<\/li>\n<li>Tr\u00fckitav aruanne: lainekuju, spekter ja numbriline kokkuv\u00f5te<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>up to &times;10<\/b><span>laager life when the tasakaalustamatus load is halved (ISO 281)<\/span><\/div>\n<div class=\"vbm-stat\"><b>-70%<\/b><span>t\u00fc\u00fcpiline vibratsiooni langus p\u00e4rast \u00fchte tasakaalustamissessiooni<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>kanalid, samaaegne omandamine<\/span><\/div>\n<div class=\"vbm-stat\"><b>5&ndash;1000&nbsp;Hz<\/b><span>anal\u00fcsaatori sagedusvahemik<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"faults\">\n<h2>Vea diagnostika - FFT spektri lugemine<\/h2>\n<p>Iga mehaaniline viga j\u00e4tab selge spektraalse s\u00f5rmej\u00e4lje. Allj\u00e4rgnevas tabelis on k\u00f5ige sagedamini esinevad vead kaardistatud nende spektraalsete tunnustega, nii et saate masina seisukorda lugeda otse Balanset-1A ekraanilt.<\/p>\n<table class=\"vbm-table\">\n<caption>Vibratsioonivigade diagnostika juhend - spektraalsignatuurid<\/caption>\n<thead>\n<tr>\n<th>Rike<\/th>\n<th>Domineerivad spektrilised komponendid<\/th>\n<th>Muud n\u00e4itajad<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Rootori tasakaalustamatus<\/b><\/td>\n<td>Tugev 1\u00d7 RPM; k\u00f5ik muud tellimused madalad<\/td>\n<td>Faas stabiilne; amplituud t\u00f5useb koos kiiruse ruuduga; kinnitatakse katse-kaalu testiga<\/td>\n<\/tr>\n<tr>\n<td><b>Nurgaline joondamatus<\/b><\/td>\n<td>T\u00f5stetud 1\u00d7 ja 2\u00d7; m\u00f5nikord 3\u00d7.<\/td>\n<td>Aksiaalne vibratsioon on sageli v\u00f5rdne v\u00f5i suurem kui radiaalne; faaside erinevus \u00fcle haakeseadme \u2248180\u00b0.<\/td>\n<\/tr>\n<tr>\n<td><b>Paralleelne joondusviga<\/b><\/td>\n<td>Tugev 2\u00d7 p\u00f6\u00f6rlemissagedus; v\u00f5ib esineda ka 1\u00d7.<\/td>\n<td>K\u00f5rge radiaalvibratsioon; 180\u00b0 faasinihkega, mis on m\u00f5\u00f5detud radiaalses suunas \u00fcle haakeseadme.<\/td>\n<\/tr>\n<tr>\n<td><b>Mehaaniline l\u00f5tvus<\/b><\/td>\n<td>Subharmoonilised (0,5\u00d7, 0,33\u00d7) ja mitmekordsed harmoonilised kuni 10\u00d7.<\/td>\n<td>Lairiba m\u00fcratase on k\u00f5rgenenud; s\u00fcmptomid halvenevad koormuse korral<\/td>\n<\/tr>\n<tr>\n<td><b>Veerelaagri kulumine<\/b><\/td>\n<td>BPFO, BPFI, BSF v\u00f5i FTF defektisagedused ja nende harmoonilised sagedused<\/td>\n<td>V\u00f5ib ilmneda enne \u00fcldise taseme t\u00f5usu; defektsageduste \u00fcmber paiknevad k\u00fclgribad kinnitavad progresseerumist.<\/td>\n<\/tr>\n<tr>\n<td><b>Resonants<\/b><\/td>\n<td>Suur amplituud loodussageduse l\u00e4hedal, mis ei ole sageli s\u00fcnkroonis p\u00f6\u00f6rlemissagedusega.<\/td>\n<td>Amplituudi tipp on teatud kiirusel; faas nihkub ~180\u00b0 v\u00f5rra l\u00e4bi resonantsi.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kui 1\u00d7 komponent domineerib, l\u00fclitage otse tasakaalustusre\u017eiimile - Balanset-1A kasutab sama m\u00f5\u00f5tmisvooru kui baasjoont m\u00f5juteguri arvutamiseks, seega ei l\u00e4he aega kaotsi.<\/p>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Miks \u00fcks \u00fcldnumber ei ole viga<\/h2>\n<p>Vibratsioonipliiats v\u00f5i lihtne RMS-m\u00f5\u00f5tja summeerib k\u00f5ik sageduskomponendid \u00fcheks arvuks. Kaks masinat v\u00f5ivad n\u00e4idata identseid \u00fcldtasemeid, kuid omada t\u00e4iesti erinevaid vigu - \u00fches domineerib 1\u00d7 tasakaalustamatus, teises laagri defektide k\u00fclgribad. Ilma sageduse lahutuseta arvate p\u00f5hjuse ja riskite vale abin\u00f5u rakendamisega. FFT lagundab signaali nii, et iga veat\u00fc\u00fcp ilmneb m\u00e4rgistatud tippuna oma iseloomulikul sagedusel, mis annab teile \u00fche ja sama m\u00f5\u00f5tmisega nii diagnoosi kui ka retsepti.<\/p>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> shows why the diagnosis matters financially. Rolling-laager basic rating life is <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b> (in millions of revolutions), where P is the equivalent dynamic laager load and p = 3 for ball laagers (10\/3 for roller laagers). Residual tasakaalustamatus adds a rotating component to that load, so halving the 1&times; vibratsioon amplitude roughly halves the tasakaalustamatus load; where this rotating load dominates P, laager life multiplies by up to 2<sup>p<\/sup>: umbes <b>8\u00d7 kuullaagrite puhul ja ~10\u00d7 rull-laagrite puhul<\/b>. The estimate holds only when the measured 1&times; vibratsioon is a reasonable proxy for the rotating dynamic laager load. Use the <a href=\"https:\/\/vibromera.eu\/et\/calculators\/bearing-load\/\">Laagri eluea kalkulaator<\/a> teie masina kokkuhoiu kvantifitseerimiseks.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>Kuidas kasutada Balanset-1A vibratsiooni anal\u00fcsaatorina - samm-sammult<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Paigaldage andurid.<\/b> Attach one or both vibratsiooniandurs to the laagri korpused using the magnetic mounts. For phase-referenced analysis, clip the laser tachometer reflective strip to the rotating v\u00f5ll and aim the sensor at it (50&ndash;500&nbsp;mm working range). Both channels record simultaneously.<\/li>\n<li><b>K\u00e4ivitage rootor ja omandage.<\/b> Avage Balanset tarkvara, valige <em>Anal\u00fcsaator<\/em> re\u017eiimi ja alustage omandamist. Tarkvara n\u00e4itab reaalajas lainekuju, FFT-spektrit ja \u00fcldist RMS-vibratsioonitaset mm\/s standardse Windowsi s\u00fclearvuti abil.<\/li>\n<li><b>Loe spektrit.<\/b> M\u00e4\u00e4rake kindlaks domineerivad sageduspiigid. Esimese astme amplituud ja faas kuvatakse automaatselt tachoimpulsi suhtes. Vaadake eespool esitatud veatabelit, et sobitada spektrimustrit k\u00f5ige t\u00f5en\u00e4olisemale veat\u00fc\u00fcbile.<\/li>\n<li><b>V\u00f5rrelda vastuv\u00f5tupiirangutega.<\/b> Kontrollida \u00fcldkiiruse n\u00e4itu vastavate <b>ISO 20816<\/b> tsooni piirid (A\/B\/C\/D) teie masinaklassi ja v\u00f5imsusklassi jaoks. Eksportige spektri graafik ja numbrilised v\u00e4\u00e4rtused hooldusaruande jaoks.<\/li>\n<li><b>Kui tasakaalustamatus leiab kinnitust, tasakaalustage see samal istungil.<\/b> Juba tehtud baasm\u00f5\u00f5tmine on m\u00f5ju-koefitsiendi j\u00e4rjestuse esimene s\u00f5it. Lisage proovikaal, k\u00e4ivitage uuesti ja laske tarkvaral arvutada korrektsioon - ei mingeid lisainstrumente, ei mingit teist k\u00fclastust.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Vibratsiooni m\u00f5\u00f5tmise standardid<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 20816<\/b> m\u00e4\u00e4ratleb mittep\u00f6\u00f6rlevate osade vibratsioonikiiruse hindamisv\u00f6\u00f6ndid (mm\/s RMS): Tsoon A (\u00e4sja kasutusele v\u00f5etud), B (vastuv\u00f5etav pikaajalise kasutamise korral), C (h\u00e4ire - viivitamatu uurimine), D (oht - kahjustuste oht). Piirv\u00e4\u00e4rtused varieeruvad masinaklassi ja v\u00f5llikeskme k\u00f5rguse j\u00e4rgi. Balanset-1A teatab \u00fcldkiiruse mm\/s RMS, nii et saate otse v\u00f5rrelda oma masina t\u00fc\u00fcbile vastava ISO 20816 osaga.<\/p>\n<p>Kui tasakaalustamatus on tuvastatud, hinnatakse tasakaalustamata j\u00e4\u00e4ki p\u00e4rast tasakaalustamist v\u00f5rreldes j\u00e4rgmisega <b>ISO 21940-11<\/b> G-klassid (G0,4 kuni G40). Balanset-1A dokumenteerib saavutatud j\u00e4\u00e4ktasakaalustamatuse oma v\u00e4ljatr\u00fckitavas aruandes, mis annab teile kontrollitava protokolli kehtiva standardi suhtes. Kasutage <a href=\"https:\/\/vibromera.eu\/et\/calculators\/residual-unbalance-iso1940\/\">j\u00e4\u00e4kide tasakaalustamatuse kalkulaator<\/a> et leida lubatud h\u00e4lve enne alustamist.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A - teie t\u00e4ielik v\u00e4ljanal\u00fcsaator ja tasakaalustuskomplekt<\/h2>\n<p>K\u00f5ik sellel lehel on tehtud \u00fche kaasaskantava instrumendiga: see on <a href=\"https:\/\/vibromera.eu\/et\/balanset-1a\/\">Balanset-1A<\/a>. See on kahe kanaliga d\u00fcnaamiline tasakaalustaja ja vibratsioonianal\u00fcsaator, mis diagnoosib FFT spektri p\u00f5hjal vead ja tasakaalustab j\u00e4igad rootorid, kui tasakaalustamatus on kinnitust leidnud. <strong>oma laagrites, t\u00f6\u00f6kiirusel<\/strong>, kasutades 3-funktsioonilist m\u00f5ju-koefitsiendi meetodit - tarkvara arvutab t\u00e4pse korrektsioonimassi ja -nurga ning salvestab aruande.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"T\u00e4ielik Balanset-1A tasakaalustuskomplekt koos andurite, lasertahomeetriga, skaala ja kohvriga.\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Mida sisaldab t\u00e4ielik komplekt<\/h3>\n<p class=\"price\">&euro;1,975 <span>- T\u00e4ielik komplekt, laos, k\u00e4ibemaksuga arve<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Liides m\u00f5\u00f5tmis\u00fcksus (USB, 2 kanalit)<\/li>\n<li>Kaks vibratsioonikiirendusm\u00f5\u00f5turit (4 m kaabel, 10 m lisavarustus)<\/li>\n<li>Lasertakomeeter \/ optiline faasiandur (50-500 mm)<\/li>\n<li>Anduri magnetiline statiiv<\/li>\n<li>Digitaalne skaala katse- ja paranduskaalude jaoks<\/li>\n<li>Windowsi tasakaalustamise ja anal\u00fc\u00fcsi tarkvara<\/li>\n<li>Plastist transpordikast<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/et\/balanset-1a\/\">Vaadake Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/et\/community\/\">K\u00fcsige meie insenerilt<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Soovitatav<\/span><\/p>\n<h3>T\u00e4iskomplekt<\/h3>\n<p>Seade - 2 andurit - lasertakomeeter - magnetiline statiiv - digitaalne skaala - tarkvara - transpordikohver. K\u00f5ik vajalik, et alustada anal\u00fc\u00fcsimist ja tasakaalustamist kohe karbist.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>OEM-komplekt<\/h3>\n<p>Seade - 2 andurit - lasertakomeeter - tarkvara. Integraatoritele, kellel on juba statiiv, kaal ja korpus v\u00f5i kes integreerivad seadme tasakaalustusmasinasse.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Peamised tehnilised n\u00e4itajad<\/caption>\n<thead>\n<tr>\n<th>Parameeter<\/th>\n<th>V\u00e4\u00e4rtus<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M\u00f5\u00f5tekanalid<\/td>\n<td>2 (\u00fche- ja kahetasandiline tasakaalustamine)<\/td>\n<\/tr>\n<tr>\n<td>Vibratsioonikiiruse vahemik<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Sagedusvahemik<\/td>\n<td>5&ndash;1000 Hz (&le;10% amplituudiviga \u00fcle 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>M\u00f5\u00f5tet\u00e4psus<\/td>\n<td>\u00b15% t\u00e4isskaalast<\/td>\n<\/tr>\n<tr>\n<td>Meetod<\/td>\n<td>3-k\u00e4iguline m\u00f5ju-koefitsiendi meetod (1 v\u00f5i 2 tasapinda)<\/td>\n<\/tr>\n<tr>\n<td>Anal\u00fc\u00fcs<\/td>\n<td>Amplituud ja faas 1\u00d7, FFT spekter ja lainekuju, salvestatud aruanded<\/td>\n<\/tr>\n<tr>\n<td>S\u00fclearvuti<\/td>\n<td>Ei kuulu komplekti (Windows PC, saadaval soovi korral)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>\u2713<\/b> Laos<\/span><span><b>\u2713<\/b> DHL Portugal 35 eurot<\/span><span><b>\u2713<\/b> DHL \u00fclemaailmselt 110 \u20ac<\/span><span><b>\u2713<\/b> 2-aastane garantii<\/span><span><b>\u2713<\/b> K\u00e4ibemaksuarve<\/span><span><b>\u2713<\/b> Inseneri toetus<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"screenshots\">\n<h2>Mida n\u00e4itab Balanset-1A anal\u00fcsaator<\/h2>\n<div class=\"vbm-cases\">\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/ChatGPT-Image-25-%D0%B8%D1%8E%D0%BB.-2025-%D0%B3.-22_07_35.webp\" alt=\"Balanset-1A kahe kanaliga vibratsioonianal\u00fcsaatori \u00fclevaateekraan\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Kahekanalilise anal\u00fcsaatori \u00fclevaade<\/h3>\n<p>\u00dcldine vibratsioonitase, FFT-spekter ja faasinurk kahest andurist, mis kuvatakse samaaegselt \u00fchel Windowsi s\u00fclearvutil.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/09\/Screenshot-2025-07-29-165701-scaled.webp\" alt=\"Reaalajas FFT-spekter, mis n\u00e4itab sageduse piike vea diagnoosimiseks\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Reaalajas FFT spekter<\/h3>\n<p>Sageduspiigid eristavad tasakaalustamatust (domineeriv 1\u00d7) paigutusveast (2\u00d7) ja laagri defektide k\u00fclgribadest.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/%D0%98%D0%B7%D0%BE%D0%B1%D1%80%D0%B0%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-WhatsApp-2025-10-03-%D0%B2-11.16.33_1bc14f9b.webp\" alt=\"Kiirendusm\u00f5\u00f5tur ja lasertakomeeter, mis on paigaldatud laagri korpusele v\u00e4litingimustes\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>M\u00f5\u00f5tmine kohapeal<\/h3>\n<p>Vibratsioon sensor and laser tachometer mounted on a running machine&rsquo;s laagri korpus &mdash; no machine disassembly required.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10461221.webp\" alt=\"Balanset tarkvaras kuvatav amplituud ja faas 1x RPM juures\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Amplituud ja faas 1\u00d7 juures<\/h3>\n<p>Esimese astme amplituud ja faasinurk, mis kuvatakse taksomeetri referentsv\u00e4\u00e4rtuse suhtes - sisendid, mis on vajalikud m\u00f5ju-koefitsiendi tasakaalustamiseks.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10418068.webp\" alt=\"V\u00e4ljatr\u00fckitav Balanset-1A m\u00f5\u00f5tmisaruanne koos lainekuju ja spektriga\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dokumenteeritud aruanne<\/h3>\n<p>Lainekuju, FFT-spekter ja numbriline kokkuv\u00f5te, mis eksporditakse tr\u00fckitava aruandena hooldusdokumendi jaoks.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Reaalsed m\u00f5\u00f5tmis- ja anal\u00fcsaatorjuhtumid<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/et\/naide\/mootmine-relatiivse-rotori-vibratsiooni-mitte-kontakt-lineaarse-nihke-sensoritega\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/image014.webp\" alt=\"Kontaktivaba vibratsiooni m\u00f5\u00f5tmine lineaarsete nihkeanduritega\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Mittekontaktne vibratsiooni m\u00f5\u00f5tmine<\/h3>\n<p>Lineaarsete nihkeandurite kasutamine suhtelise rootorivibratsiooni m\u00f5\u00f5tmiseks ilma v\u00f5llikontaktita - sobib rootorite jaoks, kus kiirendusanduri paigaldamine on ebapraktiline.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/et\/naide\/kaasaskantav-vonkumisanalusaator-ja-vonkumismasinad-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/photo_2023-04-08_17-03-49-1024x576.webp\" alt=\"Balanset-1A, mida kasutatakse nii vibratsioonianal\u00fcsaatorina kui ka kahetasandilise tasakaalustajana.\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Anal\u00fcsaator ja tasakaalustaja koos<\/h3>\n<p>Praktiline demonstratsioon sellest, kuidas \u00fcks seade katab vibratsioonianal\u00fc\u00fcsi ja kahetasandilise tasakaalustamise \u00fche t\u00f6\u00f6ga, alates diagnoosimisest kuni kontrollitud korrektsioonini.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/et\/naide\/why-balancing-doesnt-reduce-vibration-troubleshooting-guide-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/06\/ChatGPT-Image-19-%D0%B8%D1%8E%D0%BD.-2025-%D0%B3.-18_31_25.webp\" alt=\"Diagnoosimine, miks tasakaalustamine ei v\u00e4henda vibratsiooni, kasutades anal\u00fcsaatorit\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Diagnoosige enne tasakaalustamist<\/h3>\n<p>T\u00f5rkeotsingu juhend juhtudeks, kui tasakaalustamine \u00fcksi ei v\u00e4henda vibratsiooni - ja kuidas FFT-spekter paljastab tegeliku algp\u00f5hjuse.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Tasuta vibratsioonikalkulaatorid<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/et\/calculators\/bearing-load\/\">Laagri eluea kalkulaator<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/et\/calculators\/centrifugal-force-unbalance\/\">Tasakaalustamatusest tulenev tsentrifugaalj\u00f5ud<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/et\/calculators\/residual-unbalance-iso1940\/\">J\u00e4\u00e4ktasakaalustamatus (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/et\/calculators\/trial-weight-calculator\/\">Proovikaalu kalkulaator<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>Vibratsiooni anal\u00fcsaator KKK<\/h2>\n<details>\n<summary>Kuidas eristab FFT-anal\u00fc\u00fcs tasakaalustamatust paigutusvigastusest?<\/summary>\n<div class=\"ans\">Tasakaalustamatus tekitab \u00fcheainsa domineeriva piigi t\u00e4pselt 1\u00d7 jooksukiirusel. Nurgavahetus n\u00e4itab tavaliselt tugevat 2\u00d7 ja m\u00f5nikord 3\u00d7 komponenti, sageli koos k\u00f5rgenenud aksiaalvibratsiooniga. Paralleelsed k\u00f5rvalekalded tekitavad silmatorkava 2\u00d7 radiaalse tipu. Balanset-1A m\u00e4rgistab need piigid FFT-ekraanil automaatselt, et saaksite enne paranduse \u00fcle otsustamist kindlaks teha domineeriva vea. Kui 1\u00d7 komponent domineerib, l\u00e4heb sama m\u00f5\u00f5tmisvoor otse tasakaalustusarvutusse.<\/div>\n<\/details>\n<details>\n<summary>Kas ma saan Balanset-1A kasutada iseseisva anal\u00fcsaatorina ilma tasakaalustuseta?<\/summary>\n<div class=\"ans\">Jah. Seade t\u00f6\u00f6tab ainult anal\u00fcsaatori re\u017eiimis, et salvestada vibratsioonispektreid, m\u00f5\u00f5ta \u00fcldtasemeid mm\/s ja logida andmeid seisundi j\u00e4lgimise suundumuste jaoks - ilma tasakaalustusre\u017eiimi sisenemata. See on kasulik sissetuleva kontrolli, perioodiliste seisundi \u00fclevaatuste ja remondij\u00e4rgsete vastuv\u00f5tum\u00f5\u00f5tmiste puhul ISO 20816 piirv\u00e4\u00e4rtuste suhtes.<\/div>\n<\/details>\n<details>\n<summary>Millist sagedusvahemikku FFT katab ja kas sellest piisab laagrite diagnostikaks?<\/summary>\n<div class=\"ans\">The Balanset-1A covers 5 to 1000&nbsp;Hz, which captures all v\u00f5ll-order harmonics plus the fundamental laager defect frequencies (BPFO, BPFI, BSF, FTF) and their lower harmonics for most industrial rolling-element laagers at typical speeds. Be aware of the limit, however: early-stage laager damage is normally detected with high-frequency acceleration and envelope (demodulation) techniques that require bandwidth of several kHz to tens of kHz &mdash; beyond this instrument&rsquo;s range. Within 5&ndash;1000&nbsp;Hz the Balanset-1A shows laager faults once they produce measurable velocity components at the defect frequencies, i.e. at a more developed stage; it is not a substitute for a dedicated wideband laager-diagnostics instrument.<\/div>\n<\/details>\n<details>\n<summary>Kas ISO 20816 kehtib minu masina kohta?<\/summary>\n<div class=\"ans\">ISO 20816 h\u00f5lmab paljusid erinevaid p\u00f6\u00f6rlevaid masinaid, mis h\u00f5lmavad mitmeid osi: k\u00e4sitletakse pumbad, kompressorid, ventilaatorid, turbiinid, mootorid ja generaatorid. Konkreetne tsooni piir s\u00f5ltub masina v\u00f5imsusklassist ja v\u00f5lli keskkoha k\u00f5rgusest. Balanset-1A teatab \u00fcldkiiruse mm\/s RMS, nii et te kohaldate ISO 20816 mis tahes osa, mis h\u00f5lmab teie masina t\u00fc\u00fcpi, otse n\u00e4itude suhtes.<\/div>\n<\/details>\n<details>\n<summary>Kas faasi m\u00f5\u00f5tmine on piisavalt t\u00e4pne kahes tasapinnas tasakaalustamiseks?<\/summary>\n<div class=\"ans\">Jah. Faasi m\u00f5\u00f5detakse optilise tahhomeetri impulsi suhtes, mis annab korratava nurgav\u00f5rdluse. Kahe kanaliga samaaegne m\u00f5\u00f5tmine tagab, et m\u00f5lema laagri tasandite proovid v\u00f5etakse samast v\u00f5lli asendist, mis on kriitilise t\u00e4htsusega t\u00e4pse ristm\u00f5ju (m\u00f5ju koefitsiendi) arvutamiseks kahetasandilise d\u00fcnaamilise tasakaalustamise t\u00f6\u00f6de puhul.<\/div>\n<\/details>\n<details>\n<summary>Kuidas aitab anal\u00fcsaator, kui tasakaalustamine \u00fcksi ei k\u00f5rvaldanud vibratsiooni?<\/summary>\n<div class=\"ans\">Kui tasakaalustamine v\u00e4hendab 1\u00d7 komponenti, kuid \u00fcldine vibratsioon j\u00e4\u00e4b suureks, n\u00e4itab FFT kohe, milline teine sageduskomponent on muutunud domineerivaks - kas 2\u00d7 paigutusvea harmooniline, laagri defekti sagedus v\u00f5i subharmoonilise l\u00f5tvuse signatuur. See suunab t\u00e4pselt j\u00e4rgmise parandusmeetme, mitte ei j\u00e4ta tehnikut arvama. Praktilisi n\u00e4iteid leiate meie juhtumiuuringust p\u00fcsiva vibratsiooni diagnoosimise kohta.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>\u00d5ppige teooriat<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/et\/glossary\/pollu-tasakaalustamine\/\">Kohapealne tasakaalustamine<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/et\/glossary\/residual-unbalance\/\">J\u00e4relej\u00e4\u00e4nud tasakaalustamatus<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/et\/glossary\/balance-quality\/\">Tasakaalustatud kvaliteediklassid<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/et\/glossary\/dynamic-balancing\/\">D\u00fcnaamiline tasakaalustamine<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Esmalt diagnoosige - seej\u00e4rel tasakaalustage kindlalt<\/h2>\n<p>Balanset-1A annab teile kahe kanaliga FFT-anal\u00fcsaatori ja kahetasandilise tasakaalustaja \u00fches kaasaskantavas komplektis. Loe viga spektrist v\u00e4lja, korrigeeri see allikas ja kontrollige ISO 20816 j\u00e4rgi - ja seda k\u00f5ike \u00fche kohapealse k\u00fclastuse k\u00e4igus, mis maksab 1 975 eurot.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/et\/balanset-1a\/\">Vaadake Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/et\/community\/\">Esita k\u00fcsimus foorumis<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Vibration Analyzer Vibration Analyzer &mdash; Two-Channel FFT Spectrum, Phase &amp; Fault Diagnostics The Balanset-1A is a two-channel vibration analyzer that plots real-time FFT spectra, measures amplitude and phase at 1&times; RPM, and maps fault signatures to distinguish unbalance, misalignment, looseness and bearing damage &mdash; then balances in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101581","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/pages\/101581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/comments?post=101581"}],"version-history":[{"count":6,"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/pages\/101581\/revisions"}],"predecessor-version":[{"id":102102,"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/pages\/101581\/revisions\/102102"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/et\/wp-json\/wp\/v2\/media?parent=101581"}],"curies":[{"name":"t\u00f6\u00f6leht","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}