{"id":101581,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101581"},"modified":"2026-07-02T19:11:15","modified_gmt":"2026-07-02T19:11:15","slug":"vibration-analyzer","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/hr\/balancing-catalog\/vibration-analyzer\/","title":{"rendered":"Analizator vibracija i FFT spektar \u2013 Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/hr\/balancing-catalog\/\">Usluge balansiranja<\/a> \u203a Analizator vibracija<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Analizator vibracija \u2014 dvo-kanalni FFT spektar, dijagnostika faze i kvarova<\/h1>\n<p class=\"lede\">Balanset-1A je dvo-kanalni analizator vibracija koji u stvarnom vremenu iscrtava FFT spektre, mjeri amplitudu i fazu pri 1\u00d7 RPM te mapira potpisne signale kvarova kako bi razlikovao neuravnote\u017eenost, neuskla\u0111enost, labavost i o\u0161te\u0107enje le\u017eaja \u2014 a zatim balansira u istoj sesiji. Jedan prijenosni komplet za 1.975 \u20ac pokriva dijagnostiku, korekciju i verifikaciju bez prebacivanja instrumenata.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Nabavite Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/hr\/community\/\">Upitajte na\u0161eg in\u017eenjera<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/02\/interface-1-e1518391488191.webp\" alt=\"Balanset-1A analizator vibracija, FFT spektralni su\u010delje za prijenosno ra\u010dunalo\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Ukratko:<\/b> Analizator vibracija Balanset-1A istodobno bilje\u017ei dvokanalne signale sa svoja dva senzora vibracija (analogni MEMS akcelerometri), izra\u010dunava FFT spektar u stvarnom vremenu te prikazuje amplitudu i fazu na svakom harmoniku reda vratila. Neuravnote\u017eenost se pojavljuje kao dominantan vrh na 1&times; RPM; neporavnatost kao povi\u0161ene komponente 2&times; i 3&times;; razvijeni kvarovi le\u017eaja kao vrhovi BPFO\/BPFI i bo\u010dne trake; olabavljenost kao subharmonici. Budu\u0107i da se isti hardver i senzori koriste za balansiranje na terenu, kvar dijagnosticirate, ispravite ga i potvrdite rezultat u jednom posjetu lokaciji &mdash; mjere\u0107i brzinu vibracija od 0.2 do 80&nbsp;mm\/s u rasponu od 5 do 1000&nbsp;Hz.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#when\">Kada analizirati<\/a><br \/>\n<a href=\"#measures\">Ono \u0161to mjeri<\/a><br \/>\n<a href=\"#faults\">Dijagnostika kvarova<\/a><br \/>\n<a href=\"#how\">Kako se koristi<\/a><br \/>\n<a href=\"#standards\">Standardi<\/a><br \/>\n<a href=\"#device\">Balanset-1A<\/a><br \/>\n<a href=\"#screenshots\">Snimke zaslona<\/a><br \/>\n<a href=\"#cases\">Stvarni slu\u010dajevi<\/a><br \/>\n<a href=\"#calc\">Kalkulatori<\/a><br \/>\n<a href=\"#faq\">FAQ<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"when\">\n<h2>Znakovi da va\u0161 stroj treba analizu vibracija, a ne samo o\u010ditanje mjera\u010da<\/h2>\n<p>Jedan ukupan broj vibracija govori vam da ne\u0161to nije u redu. FFT spektar vam govori \u0161to i za\u0161to. Ove situacije zahtijevaju odgovaraju\u0107i analizator:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Nepoznati uzrok vibracija<\/b> Ukupna razina je povi\u0161ena, ali ne mo\u017eete utvrditi je li uzrok neuravnote\u017eenost, neporavnatost, labavost ili o\u0161te\u0107enje le\u017eaja \u2014 FFT razdvaja svaki potpis.<\/div>\n<div><b>Sna\u017ena 1\u00d7 RPM komponenta<\/b> Dominantni vrh prvog reda je klasi\u010dni potpis preostalog neuravnote\u017eenja rotora i okida\u010d za nastavak balansiranja.<\/div>\n<div><b>Povi\u0161ene 2\u00d7 ili 3\u00d7 harmonike<\/b> Izra\u017eena komponenta drugog ili tre\u0107eg reda obi\u010dno ukazuje na kutno ili paralelno neuskla\u0111ivanje spojki ili vratila.<\/div>\n<div><b>Podharmonici ili \u0161irokopojasni \u0161um<\/b> Niskoredne frekvencije kvarova le\u017eaja (BPFO, BPFI, BSF, FTF) i njihovi harmonici pojavljuju se u spektru brzine kako se kvar razvija &mdash; upozorenje koje vrijedi pratiti trendom prije zastoja, iako je za najraniju fazu o\u0161te\u0107enja potrebna visokofrekventna analiza ovojnice.<\/div>\n<div><b>Provjera prihva\u0107anja nakon popravka<\/b> Nakon uravnote\u017eenja, poravnanja ili zamjene le\u017eaja potrebni su vam izmjereni dokazi da su razine pale ispod granice prihvatljivosti ISO 20816.<\/div>\n<div><b>Periodi\u010dno ispitivanje stanja<\/b> Zapisivanje osnovnih spektra u redovitim intervalima omogu\u0107uje pra\u0107enje porasta amplituda i planiranje odr\u017eavanja prije neplaniranog zaustavljanja.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"measures\">\n<h2>\u0160to mjeri analizator Balanset-1A<\/h2>\n<p>Analizator bilje\u017ei istodobne signale s dva isporu\u010dena senzora vibracija (analogni MEMS akcelerometri), referencirane prema laserskom tahometru. Svaki dolje navedeni parametar dostupan je u jednom mjernom ciklusu:<\/p>\n<ul class=\"vbm-list\">\n<li>Ukupna brzina vibracija (mm\/s RMS) i ubrzanje (m\/s\u00b2 ili g)<\/li>\n<li>Spectrum frekvencija FFT-a u stvarnom vremenu s razlu\u010divo\u0161\u0107u koju korisnik mo\u017ee odabrati<\/li>\n<li>Oblik vala vibracije (signal u vremenskom domenu) na oba kanala istovremeno<\/li>\n<li>Fazni kut pri 1\u00d7 o\/min u odnosu na referencu tahometra vratila<\/li>\n<li>1\u00d7, 2\u00d7, 3\u00d7 i vi\u0161e redoslijednih amplituda osovine izvu\u010denih iz FFT-a<\/li>\n<li>Istovremeno dvokanalno snimanje (oba le\u017eajna ravni istovremeno)<\/li>\n<li>Brzina vrtnje (RPM) s opti\u010dkog laserskog tahometra \u2014 nije potrebna plo\u010dica s nazivom<\/li>\n<li>Grafikon trenda vibracija kroz uzastopna mjerenja<\/li>\n<li>Ispisiv izvje\u0161taj: valni oblik, spektar i numeri\u010dki sa\u017eetak<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>up to &times;10<\/b><span>vijek le\u017eaja kada se optere\u0107enje zbog neuravnote\u017eenosti prepolovi (ISO 281)<\/span><\/div>\n<div class=\"vbm-stat\"><b>\u221270%<\/b><span>tipi\u010dno smanjenje vibracija nakon jedne sesije uravnote\u017eenja<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>kanali, simultano prikupljanje<\/span><\/div>\n<div class=\"vbm-stat\"><b>5&ndash;1000&nbsp;Hz<\/b><span>frekvencijski raspon analizatora<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"faults\">\n<h2>Dijagnostika kvarova \u2014 \u010ditanje FFT spektra<\/h2>\n<p>Svaka mehani\u010dka gre\u0161ka ostavlja jedinstveni spektralni otisak. Tablica u nastavku povezuje naj\u010de\u0161\u0107e gre\u0161ke s njihovim spektralnim potpisima kako biste mogli izravno s Balanset-1A zaslona o\u010ditati stanje stroja.<\/p>\n<table class=\"vbm-table\">\n<caption>Vodi\u010d za dijagnostiku vibracijskih kvarova \u2014 spektralni potpisi<\/caption>\n<thead>\n<tr>\n<th>Kvar<\/th>\n<th>Dominantne spektralne komponente<\/th>\n<th>Ostali pokazatelji<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Neravnote\u017ea rotora<\/b><\/td>\n<td>Sna\u017ean 1\u00d7 RPM; sve ostale narud\u017ebe niske<\/td>\n<td>Faza je stabilna; amplituda raste s kvadratom brzine; potvr\u0111eno testom probnog optere\u0107enja<\/td>\n<\/tr>\n<tr>\n<td><b>Kutna neuskla\u0111enost<\/b><\/td>\n<td>Pove\u0107ano 1\u00d7 i 2\u00d7; ponekad 3\u00d7<\/td>\n<td>Osna vibracija \u010desto je jednaka ili ve\u0107a od radijalne; fazna razlika preko spoja \u2248180\u00b0<\/td>\n<\/tr>\n<tr>\n<td><b>Paralelno neporavnanje<\/b><\/td>\n<td>Sna\u017ean 2\u00d7 RPM; 1\u00d7 tako\u0111er mo\u017ee biti prisutan<\/td>\n<td>Visoka radijalna vibracija; izmjerena fazna pomaka od 180\u00b0 kroz spoj u radijalnom smjeru<\/td>\n<\/tr>\n<tr>\n<td><b>Mehani\u010dka labavost<\/b><\/td>\n<td>Podharmonici (0,5\u00d7, 0,33\u00d7) i vi\u0161estruki harmonici do 10\u00d7<\/td>\n<td>Prag \u0161uma \u0161irokopojasnog prijema je povi\u0161en; simptomi se pogor\u0161avaju s optere\u0107enjem.<\/td>\n<\/tr>\n<tr>\n<td><b>Istro\u0161avanje le\u017eaja s kotrljaju\u0107im tijelima<\/b><\/td>\n<td>Frekvencije kvarova BPFO, BPFI, BSF ili FTF i njihovi harmonici<\/td>\n<td>Mo\u017ee se pojaviti prije nego \u0161to se ukupna razina pove\u0107a; bo\u010dne trake oko frekvencija defekta potvr\u0111uju napredovanje.<\/td>\n<\/tr>\n<tr>\n<td><b>Rezonancija<\/b><\/td>\n<td>Velika amplituda u blizini vlastite frekvencije, \u010desto nije sinkrona s RPM-om<\/td>\n<td>Amplituda dosti\u017ee vrhunac pri odre\u0111enoj brzini; faza se pri rezonanciji pomakne za otprilike 180\u00b0.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kada komponenta 1\u00d7 dominira, prebacite se izravno u na\u010din uravnote\u017eenja \u2014 Balanset-1A koristi isti niz mjerenja kao osnovu za izra\u010dun koeficijenta utjecaja, pa se ne gubi vrijeme.<\/p>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Za\u0161to jedan ukupan broj propu\u0161ta gre\u0161ku<\/h2>\n<p>Vibracijska olovka ili jednostavan RMS mjera\u010d sabiru sve frekvencijske komponente u jedan broj. Dva stroja mogu pokazivati identi\u010dne ukupne razine, a ipak imati potpuno razli\u010dite kvarove \u2014 jedan dominiran 1\u00d7 neuravnote\u017eeno\u0161\u0107u, a drugi bo\u010dnim frekvencijama uzrokovanim kvarom le\u017eaja. Bez frekvencijske razlu\u010divosti naga\u0111ate uzrok i riskirate primjenu pogre\u0161nog lijeka. FFT dekomponira signal tako da se svaka vrsta kvara pojavi kao ozna\u010deni vrh na svojoj karakteristi\u010dnoj frekvenciji, daju\u0107i vam istovremeno dijagnozu i recept u jednoj mjerenju.<\/p>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> pokazuje za\u0161to je dijagnoza financijski va\u017ena. Osnovni nazivni vijek kotrljaju\u0107eg le\u017eaja je <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b> (u milijunima okretaja), gdje je P ekvivalentno dinami\u010dko optere\u0107enje le\u017eaja, a p = 3 za kugli\u010dne le\u017eajeve (10\/3 za valjkaste le\u017eajeve). Preostala neuravnote\u017eenost dodaje rotiraju\u0107u komponentu tom optere\u0107enju, pa prepolovljenje amplitude vibracija 1&times; pribli\u017eno prepolovi optere\u0107enje zbog neuravnote\u017eenosti; tamo gdje to rotiraju\u0107e optere\u0107enje dominira nad P, vijek le\u017eaja mo\u017ee se pove\u0107ati i do 2<sup>p<\/sup>: oko <b>8\u00d7 za kugli\u010dne le\u017eajeve i ~10\u00d7 za valjkaste le\u017eajeve<\/b>. Procjena vrijedi samo kada je izmjerena vibracija 1&times; razumna zamjena za rotiraju\u0107e dinami\u010dko optere\u0107enje le\u017eaja. Upotrijebite <a href=\"https:\/\/vibromera.eu\/hr\/calculators\/bearing-load\/\">kalkulator vijeka trajanja le\u017eaja<\/a> da kvantificirate u\u0161tedu za svoj stroj.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>Kako koristiti Balanset-1A kao analizator vibracija \u2014 korak po korak<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Montirajte senzore.<\/b> Pri\u010dvrstite jedan ili oba senzora vibracija na ku\u0107i\u0161ta le\u017eaja pomo\u0107u magnetskih nosa\u010da. Za analizu referenciranu po fazi pri\u010dvrstite reflektiraju\u0107u traku laserskog tahometra na rotiraju\u0107e vratilo i usmjerite senzor prema njoj (radni raspon 50&ndash;500&nbsp;mm). Oba kanala snimaju istodobno.<\/li>\n<li><b>Pokrenite rotor i zapo\u010dnite mjerenje.<\/b> Otvorite softver Balanset, odaberite <em>Analizator<\/em> Podesite na\u010din rada i zapo\u010dnite akviziciju. Softver u stvarnom vremenu na standardnom Windows laptopu prikazuje valni oblik u\u017eivo, FFT spektar i ukupnu RMS razinu vibracija u mm\/s.<\/li>\n<li><b>Pro\u010ditaj spektar.<\/b> Identificirajte dominantne frekvencijske vrhove. Amplituda i faza prvog reda automatski se prikazuju u odnosu na tahometarski impuls. Pogledajte gornju tablicu kvarova kako biste uskladili spektralni uzorak s najvjerojatnijom vrstom kvara.<\/li>\n<li><b>Usporedi s granicama prihva\u0107anja.<\/b> Provjerite o\u010ditanje ukupne brzine u odnosu na relevantno. <b>ISO 20816<\/b> granicu zone (A\/B\/C\/D) za va\u0161u klasu stroja i nazivnu snagu. Izvezite grafikon spektra i numeri\u010dke vrijednosti za izvje\u0161\u0107e o odr\u017eavanju.<\/li>\n<li><b>Ako se potvrdi neuravnote\u017eenost, uravnote\u017eite u istoj sesiji.<\/b> Osnovno mjerenje koje je ve\u0107 obavljeno slu\u017ei kao prva iteracija u nizu koeficijenata utjecaja. Dodajte probnu te\u017einu, ponovno izvedite mjerenje i dopustite softveru da izra\u010duna korekciju \u2014 bez dodatnih instrumenata, bez druge posjete.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Standardi za mjerenje vibracija<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 20816<\/b> definira zone procjene za brzinu vibracija (mm\/s RMS) na nepokretnim dijelovima: Zona A (novo pu\u0161teno u rad), B (prihvatljivo za dugoro\u010dni rad), C (uzbuna \u2014 hitna istraga), D (opasnost \u2014 rizik od o\u0161te\u0107enja). Ograni\u010denja variraju ovisno o klasi stroja i visini osovinskog centra. Balanset-1A izvje\u0161tava o ukupnoj brzini u mm\/s RMS kako biste je mogli izravno usporediti s relevantnim dijelom ISO 20816 za vrstu va\u0161eg stroja.<\/p>\n<p>Nakon \u0161to se neuravnote\u017eenost utvrdi, preostala neuravnote\u017eenost nakon balansiranja procjenjuje se u odnosu na <b>ISO 21940-11<\/b> G-klase (G0.4 do G40). Balanset-1A bilje\u017ei postignutu preostalu neuravnote\u017eenost u svom ispisu izvje\u0161\u0107a, daju\u0107i vam provjerljiv zapis u skladu s primjenjivim standardom. Koristite <a href=\"https:\/\/vibromera.eu\/hr\/calculators\/residual-unbalance-iso1940\/\">kalkulator preostalog neuravnote\u017eenja<\/a> prije nego \u0161to po\u010dnete, prona\u0111ite dopu\u0161tenu toleranciju.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A \u2014 va\u0161 potpuni terenski analizator i komplet za balansiranje<\/h2>\n<p>Sve na ovoj stranici izra\u0111eno je jednim prijenosnim instrumentom: <a href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Balanset-1A<\/a>. To je dvokanalni dinami\u010dki balanser i analizator vibracija koji dijagnosticira kvarove iz FFT spektra i, kada se neuravnote\u017eenost potvrdi, balansira krute rotore <strong>u vlastitim le\u017eajevima, pri radnoj brzini<\/strong>, koriste\u0107i metodu tropo\u010detnog koeficijenta utjecaja \u2014 softver izra\u010dunava to\u010dnu korektivnu masu i kut te sprema izvje\u0161taj.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Kompletan Balanset-1A komplet za balansiranje sa senzorima, laserskim tahometrom, vagom i futrolom\" loading=\"lazy\"><\/figure>\n<div>\n<h3>\u0160to se nalazi u kompletnom setu<\/h3>\n<p class=\"price\">1.975 \u20ac <span>\u00b7 Kompletan komplet, na zalihi, PDV ra\u010dun<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Jedinica za mjerenje su\u010delja (USB, 2 kanala)<\/li>\n<li>Dva akcelerometra za vibracije (kabel od 4 m, dodatnih 10 m)<\/li>\n<li>Laserski tahometar \/ opti\u010dki fazni senzor (50\u2013500 mm)<\/li>\n<li>Magnetski stalak za senzor<\/li>\n<li>Digitalna vaga za probne i korektivne utege<\/li>\n<li>Softver za balansiranje i analizu Windowsa<\/li>\n<li>Plasti\u010dna transportna kutija<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Pogledajte Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/hr\/community\/\">Upitajte na\u0161eg in\u017eenjera<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Preporu\u010deno<\/span><\/p>\n<h3>Puni komplet<\/h3>\n<p>Jedinica \u00b7 2 senzora \u00b7 laserski tahometar \u00b7 magnetski stalak \u00b7 digitalna vaga \u00b7 softver \u00b7 transportna torba. Sve \u0161to je potrebno za po\u010detak balansiranja iz kutije.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>OEM set<\/h3>\n<p>Jedinica \u00b7 2 senzora \u00b7 laserski tahometar \u00b7 softver. Za integratore koji ve\u0107 imaju stalak, vagu i ku\u0107i\u0161te ili koji ugra\u0111uju jedinicu u balirnu ma\u0161inu.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Klju\u010dne tehni\u010dke specifikacije<\/caption>\n<thead>\n<tr>\n<th>Parametar<\/th>\n<th>Vrijednost<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mjerni kanali<\/td>\n<td>2 (balansiranje jednoplanskog i dvoplanskog)<\/td>\n<\/tr>\n<tr>\n<td>Raspon brzine vibracija<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Frekvencijski raspon<\/td>\n<td>5&ndash;1000 Hz (&le;10% pogre\u0161ke amplitude iznad 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>To\u010dnost mjerenja<\/td>\n<td>\u00b151 TP4T od pune skale<\/td>\n<\/tr>\n<tr>\n<td>Metoda<\/td>\n<td>Metoda koeficijenta utjecaja s 3 mjerenja (1 ili 2 ravnine)<\/td>\n<\/tr>\n<tr>\n<td>Analiza<\/td>\n<td>Amplituda i faza pri 1\u00d7, FFT spektar i valni oblik, spremljena izvje\u0161\u0107a<\/td>\n<\/tr>\n<tr>\n<td>Prijenosno ra\u010dunalo<\/td>\n<td>Nije uklju\u010deno (Windows PC, dostupan na zahtjev)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>\u2713<\/b> Na zalihi<\/span><span><b>\u2713<\/b> DHL Portugal 35 \u20ac<\/span><span><b>\u2713<\/b> DHL \u0161irom svijeta 110 \u20ac<\/span><span><b>\u2713<\/b> 2-godi\u0161nje jamstvo<\/span><span><b>\u2713<\/b> PDV ra\u010dun<\/span><span><b>\u2713<\/b> In\u017eenjerska podr\u0161ka<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"screenshots\">\n<h2>\u0160to prikazuje analizator Balanset-1A<\/h2>\n<div class=\"vbm-cases\">\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/ChatGPT-Image-25-%D0%B8%D1%8E%D0%BB.-2025-%D0%B3.-22_07_35.webp\" alt=\"Pregledni zaslon dvo-kanalnog analizatora vibracija Balanset-1A\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Pregled dvo-kanalnog analizatora<\/h3>\n<p>Ukupna razina vibracija, FFT spektar i kut faze s dva senzora prikazani istovremeno na jednom Windows laptopu.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/09\/Screenshot-2025-07-29-165701-scaled.webp\" alt=\"FFT spektrum u stvarnom vremenu koji prikazuje frekvencijske vrhove za dijagnostiku kvarova\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>FFT spektar u stvarnom vremenu<\/h3>\n<p>Frekvencijski vrhovi razlikuju neuravnote\u017eenost (dominantni 1\u00d7) od neuskla\u0111enosti (2\u00d7) i bo\u010dnih pojaseva kvarova le\u017eaja.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/%D0%98%D0%B7%D0%BE%D0%B1%D1%80%D0%B0%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-WhatsApp-2025-10-03-%D0%B2-11.16.33_1bc14f9b.webp\" alt=\"Akcelerometar i laserski tahometar montirani na ku\u0107i\u0161tu le\u017eaja na terenu\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Mjerenje na terenu<\/h3>\n<p>Senzor vibracija i laserski tahometar montirani na ku\u0107i\u0161tu le\u017eaja stroja u radu &mdash; nije potrebno rastavljanje stroja.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10461221.webp\" alt=\"Amplituda i faza pri 1x RPM prikazani u softveru Balanset\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Amplituda i faza pri 1\u00d7<\/h3>\n<p>Amplituda i kut faze prvog reda prikazani u odnosu na tahometarsku referencu \u2014 ulazi potrebni za balansiranje koeficijenata utjecaja.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10418068.webp\" alt=\"Ispisiv izvje\u0161taj o mjerenju Balanset-1A s valnim oblicima i spektrom\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dokumentirano izvje\u0161\u0107e<\/h3>\n<p>Valni oblik, FFT spektar i numeri\u010dki sa\u017eetak izvoze se kao izvje\u0161\u0107e spremno za ispis za evidenciju odr\u017eavanja.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Pravi slu\u010dajevi mjerenja i analizatora<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/hr\/example\/measurement-of-relative-rotor-vibration-using-non-contact-linear-displacement-sensors\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/image014.webp\" alt=\"Bezkontaktno mjerenje vibracija sa senzorima linearnog pomaka\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Bezkontaktno mjerenje vibracija<\/h3>\n<p>Kori\u0161tenje linearnog senzora pomaka za mjerenje relativne vibracije rotora bez kontakta s vratilom \u2014 pogodno za rotore na kojima je monta\u017ea akcelerometra neprakti\u010dna.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/hr\/example\/portable-balancer-vibration-analyzer-and-balancer-machine-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/photo_2023-04-08_17-03-49-1024x576.webp\" alt=\"Balanset-1A se koristi i kao analizator vibracija i kao balanser na dvije ravnine.\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Analizator i balansir ure\u0111aj u jednom<\/h3>\n<p>Prakti\u010dna demonstracija kako jedan ure\u0111aj obuhva\u0107a analizu vibracija i balansiranje u dvije ravnine u jednom poslu, od dijagnoze do provjerene korekcije.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/hr\/example\/why-balancing-doesnt-reduce-vibration-troubleshooting-guide-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/06\/ChatGPT-Image-19-%D0%B8%D1%8E%D0%BD.-2025-%D0%B3.-18_31_25.webp\" alt=\"Dijagnosticiranje za\u0161to balansiranje ne smanjuje vibracije pomo\u0107u analizatora\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dijagnosticirajte prije nego \u0161to uravnote\u017eite.<\/h3>\n<p>Vodi\u010d za otklanjanje pote\u0161ko\u0107a u slu\u010dajevima kada samo balansiranje ne smanjuje vibracije \u2014 i kako FFT spektar otkriva stvarni korijenski uzrok.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Kalkulatori slobodnih vibracija<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/bearing-load\/\">Kalkulator vijeka trajanja le\u017eaja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/centrifugal-force-unbalance\/\">Centrifugalna sila od neuravnote\u017eenja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/residual-unbalance-iso1940\/\">Preostala neuravnote\u017eenost (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/trial-weight-calculator\/\">Kalkulator probnog utega<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>\u010cesto postavljana pitanja o analizatoru vibracija<\/h2>\n<details>\n<summary>Kako FFT analiza razlikuje neuravnote\u017eenost od neuskla\u0111enosti?<\/summary>\n<div class=\"ans\">Neravnote\u017ea stvara jedan dominantni vrh to\u010dno na 1\u00d7 brzini rada. Kutni pomak obi\u010dno pokazuje sna\u017enu 2\u00d7 komponentu, a ponekad i 3\u00d7, \u010desto uz poja\u010danu aksijalnu vibraciju. Paralelni pomak stvara izra\u017een 2\u00d7 radijalni vrh. Balanset-1A automatski ozna\u010dava te vrhove u FFT prikazu kako biste mogli identificirati dominantnu gre\u0161ku prije dono\u0161enja odluke o korekciji. Ako dominira komponenta 1\u00d7, isto mjerenje se izravno prenosi u izra\u010dun balansiranja.<\/div>\n<\/details>\n<details>\n<summary>Mogu li koristiti Balanset-1A kao samostalni analizator bez balansiranja?<\/summary>\n<div class=\"ans\">Da. Ure\u0111aj radi u na\u010dinu rada samo analizatora za snimanje spektra vibracija, mjerenje ukupnih razina u mm\/s i bilje\u017eenje podataka za trendove pra\u0107enja stanja \u2014 bez ulaska u na\u010din uravnote\u017eenja. Ovo je korisno za ulaznu inspekciju, periodi\u010dne preglede stanja i mjerenja prihva\u0107anja nakon popravka u skladu s ograni\u010denjima norme ISO 20816.<\/div>\n<\/details>\n<details>\n<summary>Koji frekvencijski raspon pokriva FFT i je li to dovoljno za dijagnostiku le\u017eajeva?<\/summary>\n<div class=\"ans\">Balanset-1A pokriva 5 do 1000&nbsp;Hz, \u010dime obuhva\u0107a sve harmonike reda vratila plus osnovne frekvencije o\u0161te\u0107enja le\u017eaja (BPFO, BPFI, BSF, FTF) i njihove ni\u017ee harmonike za ve\u0107inu industrijskih kotrljajnih le\u017eajeva pri tipi\u010dnim brzinama. Ipak, imajte na umu ograni\u010denje: o\u0161te\u0107enje le\u017eaja u ranoj fazi obi\u010dno se otkriva visokofrekventnim tehnikama ubrzanja i ovojnice (demodulacije) koje zahtijevaju \u0161irinu pojasa od nekoliko kHz do nekoliko desetaka kHz &mdash; izvan raspona ovog instrumenta. Unutar 5&ndash;1000&nbsp;Hz Balanset-1A prikazuje kvarove le\u017eaja tek kada proizvedu mjerljive komponente brzine na frekvencijama o\u0161te\u0107enja, tj. u razvijenijoj fazi; nije zamjena za namjenski \u0161irokopojasni instrument za dijagnostiku le\u017eajeva.<\/div>\n<\/details>\n<details>\n<summary>Primjenjuje li se ISO 20816 na moj stroj?<\/summary>\n<div class=\"ans\">ISO 20816 obuhva\u0107a \u0161irok raspon rotacijskih strojeva u svojim brojnim dijelovima: pumpe, kompresori, ventilatori, turbine, motori i generatori su svi obuhva\u0107eni. Specifi\u010dna granica zone ovisi o klasi snage stroja i visini osovinskog centra. Balanset-1A izvje\u0161tava o ukupnoj brzini u mm\/s RMS, pa primjenjujete onaj dio ISO 20816 koji se odnosi na vrstu va\u0161eg stroja izravno na o\u010ditanje.<\/div>\n<\/details>\n<details>\n<summary>Je li mjerenje faze dovoljno precizno za balansiranje u dvije ravnine?<\/summary>\n<div class=\"ans\">Da. Faza se mjeri u odnosu na impuls opti\u010dkog tahometra, pru\u017eaju\u0107i ponovljivu kutnu referencu. Istovremeno dvokanalno uzorkovanje osigurava da se u obje ravnine le\u017eaja uzorkuje na istoj poziciji vratila, \u0161to je klju\u010dno za to\u010dne izra\u010dune kri\u017enog u\u010dinka (koeficijenta utjecaja) pri dinami\u010dkom balansiranju u dvije ravnine.<\/div>\n<\/details>\n<details>\n<summary>Kako analizator poma\u017ee kada balansiranje samo po sebi nije otklonilo vibraciju?<\/summary>\n<div class=\"ans\">Kada balansiranje smanji komponentu 1\u00d7, ali ukupna vibracija ostaje visoka, FFT odmah pokazuje koja je druga frekvencijska komponenta postala dominantna \u2014 bilo da se radi o harmonici neuskla\u0111enosti 2\u00d7, frekvenciji kvarova le\u017eaja ili signaturi podharmoni\u010dke labavosti. To precizno usmjerava sljede\u0107i korektivni korak umjesto da tehni\u010dara ostavlja da naga\u0111a. Pogledajte na\u0161u studiju slu\u010daja o dijagnosticiranju uporne vibracije za prakti\u010dne primjere.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Nau\u010di teoriju<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/field-balancing\/\">Balansiranje na terenu<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/residual-unbalance\/\">Preostala neuravnote\u017eenost<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/balance-quality\/\">Razredi kvalitete uravnote\u017eenja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/dynamic-balancing\/\">Dinami\u010dko uravnote\u017eenje<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Prvo dijagnosticirajte \u2014 zatim uravnote\u017eite s povjerenjem<\/h2>\n<p>Balanset-1A vam pru\u017ea dvo-kanalni FFT analizator i balanser s dva ravnine u jednom prijenosnom kompletu. O\u010ditajte kvar iz spektra, ispravite ga na izvoru i provjerite prema ISO 20816 \u2014 sve u jednom posjetu lokaciji za 1.975 \u20ac.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Pogledajte Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/hr\/community\/\">Postavite pitanje na forumu<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Vibration Analyzer Vibration Analyzer &mdash; Two-Channel FFT Spectrum, Phase &amp; Fault Diagnostics The Balanset-1A is a two-channel vibration analyzer that plots real-time FFT spectra, measures amplitude and phase at 1&times; RPM, and maps fault signatures to distinguish unbalance, misalignment, looseness and bearing damage &mdash; then balances in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101581","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/comments?post=101581"}],"version-history":[{"count":6,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101581\/revisions"}],"predecessor-version":[{"id":102102,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101581\/revisions\/102102"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/media?parent=101581"}],"curies":[{"name":"radni list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}