{"id":101583,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101583"},"modified":"2026-07-02T19:04:34","modified_gmt":"2026-07-02T19:04:34","slug":"upgrade-balancing-machine","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/hr\/balancing-catalog\/upgrade-balancing-machine\/","title":{"rendered":"Nadogradnja stare ma\u0161ine za balansiranje s Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/hr\/balancing-catalog\/\">Usluge balansiranja<\/a> \u203a Nadogradnja ure\u0111aja za balansiranje<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Nadogradnja stare sprave za balansiranje \u2014 retrofit s Balanset-1A<\/h1>\n<p class=\"lede\">Mehani\u010dko postolje va\u0161eg stroja za balansiranje, kalibrirana postolja i pogonsko vreteno jo\u0161 uvijek imaju desetlje\u0107a vijeka pred sobom. Zastarjela je mjerna elektronika: stara analogna jedinica, ra\u010dunalo s disketnim pogonom, nepodr\u017eane kartice senzora. Zamijenite cijeli sustav mjerenja i ra\u010dunanja s <strong>Balanset-1A OEM set za \u20ac1.735<\/strong> i pokrenite svoj postoje\u0107i stroj s modernim dvokanalnim digitalnim mjerenjem, FFT analizom, izvje\u0161tavanjem prema ISO 21940-11 i bez stalnih licencnih naknada.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Pregledajte OEM set<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/hr\/community\/\">Upitajte na\u0161eg in\u017eenjera<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/IMG_20230409_143717_237-1024x768.webp\" alt=\"Stroj za balansiranje s tvrdim le\u017eajevima, retrofitan modernim mjernim sustavom Balanset-1A\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Ukratko:<\/b> Modernizacija starog balansirnog stroja zna\u010di zamjenu samo njegove mjerne elektronike &mdash; senzora, jedinice za kondicioniranje signala i softvera &mdash; uz zadr\u017eavanje provjerene mehani\u010dke strukture netaknutom. Balanset-1A OEM set (jedinica + 2 akcelerometra vibracija + laserski tahometar + softver, &euro;1,735) ugra\u0111uje se u jednom danu na bilo koji stroj s tvrdim ili mekim le\u017eajevima, dodaje dvoplansko dinami\u010dko balansiranje, FFT analizu vibracija i ispisiva ISO 21940-11 izvje\u0161\u0107a te ko\u0161ta otprilike 10&ndash;60&times; manje od novog stroja.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#signs\">Kada nadograditi<\/a><br \/>\n<a href=\"#why\">Tro\u0161ak zamjene naspram retrofita<\/a><br \/>\n<a href=\"#adds\">\u0160to retrofit dodaje<\/a><br \/>\n<a href=\"#how\">Postupak korak po korak<\/a><br \/>\n<a href=\"#compare\">Prije i poslije<\/a><br \/>\n<a href=\"#device\">Balanset-1A OEM set<\/a><br \/>\n<a href=\"#cases\">Stvarni slu\u010dajevi<\/a><br \/>\n<a href=\"#calc\">Kalkulatori<\/a><br \/>\n<a href=\"#faq\">FAQ<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"signs\">\n<h2>Znakovi da va\u0161 stroj za balansiranje treba nadogradnju mjernog sustava<\/h2>\n<p>Mehani\u010dki dio ma\u0161ine za balansiranje s tvrdim ili mekim le\u017eajevima rijetko se prvi put istro\u0161i \u2014 elektronika se istro\u0161i. Ovi simptomi zna\u010de da je mjerni sustav usko grlo, a ne sama ma\u0161ina:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Softver radi samo na Windows XP ili starijim verzijama.<\/b> Softver za kontrolu vezan je uz mrtvi operativni sustav: nema sigurnosnih zakrpa, nema podr\u0161ke za moderne upravlja\u010dke programe, a dobavlja\u010d vi\u0161e ne postoji.<\/div>\n<div><b>Zamjenski dijelovi nisu dostupni<\/b> Kartice za su\u010delje senzora, ISA\/PCI mostne plo\u010de i moduli za prikaz vi\u0161e se ne proizvode i nemogu\u0107e ih je nabaviti nigdje.<\/div>\n<div><b>Neto\u010dna ili \u0161umovita o\u010ditanja<\/b> Stari analogni sklopovi za obradu uvode odstupanja, pogre\u0161ke poja\u010danja i neponovljivost koje moderna 24-bitna ADC tehnologija eliminira.<\/div>\n<div><b>Nema izvje\u0161tavanja u skladu s ISO standardima<\/b> Stari sustav ispisuje brojeve amplitude, ali ne mo\u017ee izra\u010dunati vrijednosti rezidualnog neuravnote\u017eenja g\u00b7mm i usporedbu G-klase potrebnu prema ISO 21940-11.<\/div>\n<div><b>Ograni\u010denje na jednu ravan<\/b> Mnogi stariji strojevi isporu\u010deni su s elektronikom za jednu ravninu; dinami\u010dko balansiranje u dvije ravnine \u0161irokih ili konzolnih rotora nemogu\u0107e je bez nadogradnje hardvera.<\/div>\n<div><b>Nema FFT-a ili prikaza faze<\/b> Moderna dijagnostika zahtijeva o\u010ditavanje frekvencijskog spektra i kut faze. Analogni mjera\u010di na plo\u010di ne mogu prikazati ni jedno ni drugo.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"why\">\n<h2>Tro\u0161ak potpune zamjene naspram ciljanog retrofita<\/h2>\n<p>Ma\u0161ina za balansiranje s tvrdim le\u017eajevima u svojoj je biti precizna mehani\u010dka konstrukcija: kruta postolja, kalibrirana potporna postolja i stabilna pogonska vretena. Ti dijelovi imaju vi\u0161edecenijsku vijek trajanja uz redovno odr\u017eavanje. Mjerni sustav \u2014 senzori, priprema signala, A\/D pretvara\u010d i softver \u2014 prati \u017eivotni ciklus potro\u0161a\u010dke elektronike: pet do deset godina prije nego \u0161to platforma ostane bez podr\u0161ke i dijelovi postanu rijetki.<\/p>\n<p>Kada elektronika otka\u017ee, rashodovati cijeli stroj nije racionalan odgovor. Potpuna zamjena je kapitalni projekt: &euro;15,000 do &euro;100,000+ za opremu, plus instalacija, pu\u0161tanje u rad i dodatna obuka osoblja. Balanset-1A OEM komplet mjernog sustava po cijeni od &euro;1,735 ugra\u0111uje se u va\u0161 postoje\u0107i stroj u jednom radnom danu, povezuje se na postoje\u0107a le\u017eajna postolja i preuzima va\u0161a trenutna mjesta monta\u017ee senzora (uz kori\u0161tenje novih isporu\u010denih senzora vibracija) te radi na bilo kojem modernom Windows prijenosnom ra\u010dunalu. Mehani\u010dka preciznost koju ste platili ostaje; zamjenjuje se samo zastarjela elektronika.<\/p>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>1.735 \u20ac<\/b><span>Tro\u0161ak OEM seta u usporedbi s 15.000\u2013100.000 \u20ac za novu ma\u0161inu<\/span><\/div>\n<div class=\"vbm-stat\"><b>1 dan<\/b><span>tipi\u010dno vrijeme retrofit instalacije<\/span><\/div>\n<div class=\"vbm-stat\"><b>2 ravnine<\/b><span>dinami\u010dko balansiranje s potpunom FFT analizom<\/span><\/div>\n<div class=\"vbm-stat\"><b>ISO 21940-11<\/b><span>Uskla\u0111eni izvje\u0161taji za ispis<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"adds\">\n<h2>\u0160to Balanset-1A retrofit dodaje va\u0161oj staroj ma\u0161ini<\/h2>\n<div class=\"vbm-callout\">\n<p><b>Moderno dvo-kanalno mjerenje.<\/b> Balanset-1A USB su\u010delje zamjenjuje va\u0161u staru jednokanalnu analognu elektroniku 24-bitnim dvo-kanalnim ADC-om. Oba postolja le\u017eaja mjere se istovremeno \u2014 \u0161to je klju\u010dno za dinami\u010dko balansiranje na dvije ravnine \u0161irokih rotora.<\/p>\n<p><b>FFT spektar i o\u010ditavanje faze.<\/b> Svaki mjerni ciklus proizvodi potpuni spektar u frekvencijskom domenu, tako da mo\u017eete razlikovati neuravnote\u017eenost (1\u00d7RPM), neuskla\u0111enost (2\u00d7RPM) i strukturni rezonanc. Kut faze se prikazuje i bilje\u017ei za svaki ciklus.<\/p>\n<p><b>Softver za koeficijent utjecaja.<\/b> Softver Balanset vodi operatera kroz sustavni postupak izra\u010duna koeficijenta utjecaja u tri koraka: osnovno ispitivanje, ispitivanje s probnim optere\u0107enjem, izra\u010dun korekcije. Nije potrebna ru\u010dna vektorska aritmetika. Podr\u017eava jednoplanovni i dvoplanovni na\u010din rada.<\/p>\n<p><b>Ispisivi ISO 21940-11 izvje\u0161taji.<\/b> Nakon svake sesije uravnote\u017eenja softver generira izvje\u0161\u0107e koje sadr\u017ei po\u010detnu i preostalu neuravnote\u017eenost u g\u00b7mm, usporedbu G-grade i potpunu povijest izvo\u0111enja. Pogodno za evidenciju upravljanja kvalitetom i dokumentaciju za kupce.<\/p>\n<p><b>Laserski tahometar zamjenjuje mehani\u010dke okida\u010dke sklopove.<\/b> Opti\u010dki senzor faze montira se na magnetskom stalku i \u010dita reflektiraju\u0107u traku, zamjenjuju\u0107i istro\u0161ene ili nepouzdane mehani\u010dke sklopove za pokretanje faze na starijim strojevima.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>Kako retrofiti Balanset-1A u svoju ma\u0161inu \u2014 korak po korak<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Procijenite postoje\u0107u mehani\u010dku strukturu.<\/b> Potvrdite da le\u017eajna postolja stroja, pogon i kompenzacija izbijanja i dalje zadovoljavaju specifikaciju. Ako zadovoljavaju, na mehani\u010dkoj strani nije potreban nikakav rad. Dokumentirajte postoje\u0107e polo\u017eaje monta\u017ee senzora na le\u017eajnim postoljima &mdash; senzori vibracija isporu\u010deni uz Balanset jedinicu bit \u0107e ugra\u0111eni na ista mjerna mjesta.<\/li>\n<li><b>Pove\u017eite senzore s novom jedinicom.<\/b> Montirajte dva isporu\u010dena akcelerometra vibracija na ku\u0107i\u0161ta le\u017eajnih postolja u standardnoj orijentaciji i priklju\u010dite ih na su\u010delnu jedinicu Balanset-1A pomo\u0107u njihovih prilo\u017eenih kabela. Jedinica je projektirana za rad s vlastitim uparenim senzorima; ako umjesto toga \u017eelite ponovno upotrijebiti postoje\u0107e senzore stroja, najprije provjerite kompatibilnost s nama.<\/li>\n<li><b>Instalirajte fazni okida\u010d.<\/b> Usmjerite laserski tahometar na reflektiraju\u0107u traku pri\u010dvr\u0161\u0107enu na rotor ili vreteno. Magnetski stalak za laser pri\u010dvr\u0161\u0107uje se na postolje stroja bez bu\u0161enja. To zamjenjuje bilo koji postoje\u0107i mehani\u010dki ili opti\u010dki okida\u010dki sklop.<\/li>\n<li><b>Konfigurirajte softver.<\/b> Instalirajte softver Balanset na Windows prijenosno ra\u010dunalo (Windows 7 do Windows 11). Unesite osjetljivosti senzora, konstante krutosti pedestala iz izvornog kalibracijskog zapisa stroja i raspon mase rotora koji namjeravate uravnote\u017eiti. Spremite kao profil stroja.<\/li>\n<li><b>Pokrenite kalibracijski rotor.<\/b> Koristite kalibracijski rotor poznate mase (ili svoj prvi proizvodni rotor s precizno odmjerenom probnom te\u017einom) kako biste provjerili da se izmjerena neuravnote\u017eenost podudara s poznatom vrijedno\u0161\u0107u. Metoda koeficijenta utjecaja se samokalibrira za svaki tip rotora; nije potrebna vanjska kalibracijska usluga.<\/li>\n<li><b>Verificirati prema ISO 21940-11.<\/b> Pokrenite provjeru rotora kako biste potvrdili da je preostalo neuravnote\u017eenje nakon postupka uravnote\u017eenja unutar tolerancije G-klase potrebne za va\u0161u klasu rotora. Ispi\u0161ite i arhivirajte rezultat kao zapis o pu\u0161tanju u rad.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"compare\">\n<h2>Prije i poslije: stari analogni ure\u0111aj nasuprot onome nadogra\u0111enom Balansetom<\/h2>\n<table class=\"vbm-table\">\n<caption>Stari analogni sustav mjerenja nasuprot retrofitu Balanset-1A<\/caption>\n<thead>\n<tr>\n<th>Sposobnost<\/th>\n<th>Stari analogni sustav<\/th>\n<th>Retrofit Balanset-1A<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mjerni kanali<\/td>\n<td class=\"no\">1 (samo jednoplanski)<\/td>\n<td class=\"yes\">2 (jednoplansko i dvoplansko)<\/td>\n<\/tr>\n<tr>\n<td>FFT frekvencijski spektar<\/td>\n<td class=\"no\">Ne \u2014 samo analogni brojilac<\/td>\n<td class=\"yes\">Da \u2014 zaslon punog spektra<\/td>\n<\/tr>\n<tr>\n<td>O\u010ditavanje kutnog pomaka<\/td>\n<td class=\"no\">Procjena stroboskopom<\/td>\n<td class=\"yes\">Digitalno, zabilje\u017eeno po svakom izvo\u0111enju<\/td>\n<\/tr>\n<tr>\n<td>Izvje\u0161\u0107e ISO 21940-11<\/td>\n<td class=\"no\">Nije mogu\u0107e<\/td>\n<td class=\"yes\">Ispisano nakon svake sesije<\/td>\n<\/tr>\n<tr>\n<td>Preostali neravnote\u017ea u g\u00b7mm<\/td>\n<td class=\"no\">Nije izra\u010dunato<\/td>\n<td class=\"yes\">Izra\u010dunato i prikazano<\/td>\n<\/tr>\n<tr>\n<td>Povezivost s PC-jem<\/td>\n<td class=\"no\">Disketa \/ nema<\/td>\n<td class=\"yes\">USB, Windows 7\u201311<\/td>\n<\/tr>\n<tr>\n<td>Spremljena povijest tr\u010danja<\/td>\n<td class=\"no\">Grafikon na papirnim trakama<\/td>\n<td class=\"yes\">Digitalna datoteka, tiskivo<\/td>\n<\/tr>\n<tr>\n<td>R\u0435\u0437\u0435\u0440\u0432\u043d\u0438 dijelovi<\/td>\n<td class=\"no\">Ukinuto<\/td>\n<td class=\"yes\">U proizvodnji, 2-godi\u0161nje jamstvo<\/td>\n<\/tr>\n<tr>\n<td>Tro\u0161ak nadogradnje<\/td>\n<td>\u2014<\/td>\n<td class=\"yes\">1.735 \u20ac OEM set<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Mehani\u010dka to\u010dnost izvorne strojne opreme \u2014 krutost stola, krutost postolja, radijalna pogre\u0161ka pogona \u2014 u potpunosti je o\u010duvana. Zamijenjena je samo mjerna i ra\u010dunalna oprema.<\/p>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A \u2014 mjerni sustav koji zamjenjuje va\u0161u staru elektroniku<\/h2>\n<p>The <a href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Balanset-1A<\/a> je dvokanalni dinami\u010dki balanser i analizator vibracija namijenjen zamjeni mjerne elektronike bilo kojeg postoje\u0107eg balansirnog stroja s tvrdim ili mekim le\u017eajevima. Povezuje se s le\u017eajnim postoljima va\u0161eg stroja preko isporu\u010denih akcelerometara vibracija i s rotorom preko laserskog tahometra, a zatim u softveru izvodi metodu koeficijenta utjecaja s 3 pokretanja &mdash; izra\u010dunava to\u010dnu korekcijsku masu i kut te sprema potpuno ISO 21940-11 izvje\u0161\u0107e. Ovaj <strong>OEM set<\/strong> (jedinica + 2 senzora + laserski tahometar + softver \u2014 bez transportne kutije, digitalne vage ili magnetskog stalka) je namjenska konfiguracija za integratore koji preure\u0111uju stroj.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Kompletan Balanset-1A komplet za balansiranje sa senzorima, laserskim tahometrom, vagom i futrolom\" loading=\"lazy\"><\/figure>\n<div>\n<h3>\u0160to se nalazi u kompletnom setu<\/h3>\n<p class=\"price\">1.975 \u20ac <span>\u00b7 Kompletan komplet, na zalihi, PDV ra\u010dun<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Jedinica za mjerenje su\u010delja (USB, 2 kanala)<\/li>\n<li>Dva akcelerometra za vibracije (kabel od 4 m, dodatnih 10 m)<\/li>\n<li>Laserski tahometar \/ opti\u010dki fazni senzor (50\u2013500 mm)<\/li>\n<li>Magnetski stalak za senzor<\/li>\n<li>Digitalna vaga za probne i korektivne utege<\/li>\n<li>Softver za balansiranje i analizu Windowsa<\/li>\n<li>Plasti\u010dna transportna kutija<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Pogledajte Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/hr\/community\/\">Upitajte na\u0161eg in\u017eenjera<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant\"><span class=\"tag\">Preporu\u010deno<\/span><\/p>\n<h3>Puni komplet<\/h3>\n<p>Jedinica \u00b7 2 senzora \u00b7 laserski tahometar \u00b7 magnetski stalak \u00b7 digitalna vaga \u00b7 softver \u00b7 transportna torba. Sve \u0161to je potrebno za po\u010detak balansiranja iz kutije.<\/p>\n<\/div>\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>OEM set \u2014 za naknadnu opremu stroja<\/h3>\n<p>Jedinica \u00b7 2 senzora \u00b7 laserski tahometar \u00b7 softver \u2014 bez transportne kutije, digitalne vage ili magnetskog stalka. Namijenjeno integratorima koji ugra\u0111uju mjerni sustav u postoje\u0107i stroj za balansiranje. 1.735 \u20ac. Namjenska konfiguracija za naknadnu ugradnju.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Klju\u010dne tehni\u010dke specifikacije<\/caption>\n<thead>\n<tr>\n<th>Parametar<\/th>\n<th>Vrijednost<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mjerni kanali<\/td>\n<td>2 (balansiranje jednoplanskog i dvoplanskog)<\/td>\n<\/tr>\n<tr>\n<td>Raspon brzine vibracija<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Frekvencijski raspon<\/td>\n<td>5&ndash;1000 Hz (&le;10% pogre\u0161ke amplitude iznad 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>To\u010dnost mjerenja<\/td>\n<td>\u00b151 TP4T od pune skale<\/td>\n<\/tr>\n<tr>\n<td>Metoda<\/td>\n<td>Metoda koeficijenta utjecaja s 3 mjerenja (1 ili 2 ravnine)<\/td>\n<\/tr>\n<tr>\n<td>Analiza<\/td>\n<td>Amplituda i faza pri 1\u00d7, FFT spektar i valni oblik, spremljena izvje\u0161\u0107a<\/td>\n<\/tr>\n<tr>\n<td>Standardi<\/td>\n<td>ISO 21940-11 izvje\u0161tavanje o preostalom neuravnote\u017eenju<\/td>\n<\/tr>\n<tr>\n<td>Prijenosno ra\u010dunalo<\/td>\n<td>Nije uklju\u010deno (Windows 7\u201311, dostupno na zahtjev)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>\u2713<\/b> Na zalihi<\/span><span><b>\u2713<\/b> DHL Portugal 35 \u20ac<\/span><span><b>\u2713<\/b> DHL \u0161irom svijeta 110 \u20ac<\/span><span><b>\u2713<\/b> 2-godi\u0161nje jamstvo<\/span><span><b>\u2713<\/b> PDV ra\u010dun<\/span><span><b>\u2713<\/b> In\u017eenjerska podr\u0161ka<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Pravi slu\u010dajevi retrofitinga i nadogradnje<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/hr\/example\/modernization-of-an-old-balancing-machine-with-hard-bearing-supports\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/IMG_20230409_143717_237-1024x768.webp\" alt=\"Modernizacija stare balansne ma\u0161ine za tvrda le\u017eajeva pomo\u0107u retrofita Balanset-1A\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Modernizirana je strojna oprema za tvrda le\u017eanja.<\/h3>\n<p>Potpuna modernizacija starog balansirnog stroja s tvrdim le\u017eajevima: novi senzori vibracija, nova Balanset mjerna jedinica, moderan softver &mdash; mehani\u010dka struktura nepromijenjena.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/hr\/example\/using-our-equipment-as-a-measurement-and-computing-system-in-balancing-machines-video-inside\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-512x1024.webp\" alt=\"Balanset-1A OEM jedinica integrirana kao mjerni i ra\u010dunalni sustav u stroju za balansiranje\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Balanset kao OEM mjerni sustav<\/h3>\n<p>Video demonstracija OEM jedinice Balanset integrirane kao trajni sustav za mjerenje i ra\u010dunanje u postoje\u0107oj proizvodnoj balansirnoj stroji.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/hr\/diy-balancing-machines\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/04\/%D0%A0%D0%BE%D1%82%D0%B5%D1%80_1-scaled-e1713661998794-1024x220.webp\" alt=\"Uradi-sam balansna ma\u0161ina izgra\u0111ena oko elektronike Balanset-1A kao osnovnog mjernog sustava\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Strojevi za balansiranje uradi sam<\/h3>\n<p>In\u017eenjeri koji su izgradili vlastite postolje za le\u017eajeve i pogonske sustave oko mjernog ure\u0111aja Balanset kao elektroni\u010dkog jezgre \u2014 isti pristup kao nadogradnja.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Tolerancije i standardi<\/h2>\n<div class=\"vbm-callout\"><b>ISO 21940-11<\/b> (ranije ISO 1940-1) specificira razrede kvalitete balansa za krute rotore od G0.4 do G4000. Nakon naknadne opreme Balanset-1A kao mjernog sustava, va\u0161 stroj daje rezultate preostalog nebalansa izra\u017eene u g\u00b7mm i ocijenjene prema toleranciji G-razreda za radnu brzinu i masu rotora. Koristite na\u0161 <a href=\"https:\/\/vibromera.eu\/hr\/calculators\/residual-unbalance-iso1940\/\">kalkulator preostalog neuravnote\u017eenja<\/a> Da bi se prije po\u010detka odredila dopu\u0161tena tolerancija. Softver Balanset generira ispisani izvje\u0161taj prikladan za sustav upravljanja kvalitetom. OEM varijanta tako\u0111er podr\u017eava integraciju u poluautomatske ili proizvodne stanice za balansiranje. Pobolj\u0161anje vijeka trajanja le\u017eaja nakon uspje\u0161nog balansiranja slijedi <b>ISO 281<\/b>Otprilike prepolovljavanje amplitude vibracija pove\u0107ava vijek trajanja valjkastog le\u017eaja za 8\u201310 puta.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Besplatni kalkulatori nadogradnje<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/residual-unbalance-iso1940\/\">Preostala neuravnote\u017eenost (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/trial-weight-calculator\/\">Kalkulator probnog utega<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/calculators\/bearing-load\/\">Kalkulator vijeka trajanja le\u017eaja<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>\u010cesto postavljana pitanja o retrofitu i nadogradnji<\/h2>\n<details>\n<summary>Radi li jedinica Balanset s mojim postoje\u0107im senzorima?<\/summary>\n<div class=\"ans\">U tipi\u010dnoj modernizaciji stari se senzori jednostavno zamjenjuju: Balanset-1A isporu\u010duje se s vlastitim uparenim akcelerometrima vibracija, koji se montiraju na ista mjerna mjesta na le\u017eajnim postoljima i spajaju vlastitim kabelima. Jedinica je projektirana za rad s tim isporu\u010denim senzorima; kompatibilnost s postoje\u0107im senzorima tre\u0107ih strana (ICP\/IEPE ili charge-mode) mora se potvrditi od slu\u010daja do slu\u010daja &mdash; opi\u0161ite svoj tip senzora na <a href=\"https:\/\/vibromera.eu\/hr\/community\/\">foruma zajednice<\/a> i savjetovat \u0107emo vas.<\/div>\n<\/details>\n<details>\n<summary>Mo\u017ee li zamijeniti elektroniku na stroju s mekani\u010dkim le\u017eajem mekog i tvrdog tipa?<\/summary>\n<div class=\"ans\">Da. Metoda koeficijenata utjecaja koju koristi softver Balanset radi i s vrstama strojeva s tvrdim le\u017eajevima i s mekim le\u017eajevima. Pristup kalibraciji se neznatno razlikuje \u2014 strojevi s tvrdim le\u017eajevima koriste dimenzionalnu kalibraciju; strojevi s mekim le\u017eajevima zahtijevaju kalibracijsku izvedbu s poznatom probnom masom \u2014 ali oba su tijeka rada u potpunosti podr\u017eana u softveru.<\/div>\n<\/details>\n<details>\n<summary>Koja je razlika izme\u0111u OEM seta i standardnog Full Kita?<\/summary>\n<div class=\"ans\">OEM set (&euro;1,735) uklju\u010duje dvokanalnu USB mjernu jedinicu, dva akcelerometra vibracija, laserski tahometar i softver, zapakirane za trajnu ugradnju unutar balansirnog stroja. Ne uklju\u010duje transportni kov\u010deg, digitalnu vagu ni magnetski stalak za senzor. Full Kit (&euro;1,975) dodaje te stavke i optimiziran je za prijenosnu terensku upotrebu. Oba koriste identi\u010dan softver i daju identi\u010dne mjerne rezultate. Za modernizaciju stroja OEM set je namjenski izbor.<\/div>\n<\/details>\n<details>\n<summary>Je li na stroju za balansiranje potrebno obaviti neki mehani\u010dki rad?<\/summary>\n<div class=\"ans\">Obi\u010dno ne. Retrofit zamjenjuje samo mjernu elektroniku \u2014 senzore, su\u010delno jedinicu i softver. Stalak, postolja, valjci i pogon ostaju netaknuti. Ako stroj nije bio kori\u0161ten dulje vrijeme, op\u0107a servisna provjera (podmazivanje, provjera odskoka, provjera krutosti postolja) dobra je praksa prije ponovnog pu\u0161tanja u rad, ali to je neovisno o nadogradnji elektronike.<\/div>\n<\/details>\n<details>\n<summary>Koliko obi\u010dno traje ugradnja retrofita?<\/summary>\n<div class=\"ans\">Za tehni\u010dara upoznatog s ure\u0111ajem, spajanje senzora i laserskog tahometra, instalacija softvera i dovr\u0161avanje prve kalibracije rotora obi\u010dno traje jedan radni dan. Ako su originalni snopovi kabela i terminalne trake netaknuti, instalacija mo\u017ee biti br\u017ea. Pogledajte <a href=\"https:\/\/vibromera.eu\/hr\/how-it-works\/\">Vodi\u010d korak po korak<\/a> za cijeli postupak.<\/div>\n<\/details>\n<details>\n<summary>Mo\u017ee li se OEM set Balanset integrirati u automatiziranu ili poluautomatiziranu proizvodnu liniju?<\/summary>\n<div class=\"ans\">Da. Softver Balanset mo\u017ee se pokretati iz skripte ili integrirati u poluautomatsku stanicu. Jedinica komunicira putem USB-a, a softver pru\u017ea strukturirani izlaz prikladan za evidentiranje u proizvodnu bazu podataka ili sustav kvalitete. Kontaktirajte nas putem <a href=\"https:\/\/vibromera.eu\/hr\/community\/\">foruma zajednice<\/a> Kako bismo razgovarali o va\u0161im specifi\u010dnim zahtjevima za integraciju.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Nau\u010di teoriju<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/balance-quality\/\">Razredi kvalitete uravnote\u017eenja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/dynamic-balancing\/\">Dinami\u010dko uravnote\u017eenje<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/two-plane-balancing\/\">Balansiranje u dvije ravnine<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/residual-unbalance\/\">Preostala neuravnote\u017eenost<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/hr\/glossary\/field-balancing\/\">Balansiranje na terenu<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Ne bacite dobru ma\u0161inu \u2014 modernizirajte je danas<\/h2>\n<p>Balanset-1A OEM set daje va\u0161oj postoje\u0107oj balansirnoj ma\u0161ini potpuno moderno nadogradnju \u2014 digitalno mjerenje u dvije ravnine, FFT analizu, o\u010ditavanje faze i izvje\u0161tavanje prema ISO 21940-11 \u2014 za 1.735 \u20ac. O\u010duvajte mehani\u010dku investiciju; zamijenite samo zastarjelu elektroniku.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/hr\/balanset-1a\/\">Pregledajte OEM set<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/hr\/community\/\">Opi\u0161ite svoju ma\u0161inu na forumu<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Upgrade a Balancing Machine Upgrade an Old Balancing Machine &mdash; Retrofit with Balanset-1A Your balancing machine&rsquo;s mechanical bed, calibrated pedestals and drive spindle still have decades of life in them. What&rsquo;s obsolete is the measuring electronics: the old analogue unit, the floppy-disk computer, the unsupported sensor cards. [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101583","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/comments?post=101583"}],"version-history":[{"count":5,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101583\/revisions"}],"predecessor-version":[{"id":102095,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101583\/revisions\/102095"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/hr\/wp-json\/wp\/v2\/media?parent=101583"}],"curies":[{"name":"radni list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}