{"id":101581,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101581"},"modified":"2026-07-02T19:11:15","modified_gmt":"2026-07-02T19:11:15","slug":"vibration-analyzer","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/lt\/balancing-catalog\/vibration-analyzer\/","title":{"rendered":"Vibracij\u0173 analizatorius &#038; FFT spektras &#8211; Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/lt\/balancing-catalog\/\">Balansavimo paslaugos<\/a> &rsaquo; Vibracij\u0173 analizatorius<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Vibracij\u0173 analizatorius &mdash; dviej\u0173 kanal\u0173 FFT spektras, faz\u0117 ir gedim\u0173 diagnostika<\/h1>\n<p class=\"lede\">Balanset-1A yra dviej\u0173 kanal\u0173 vibracij\u0173 analizatorius, kuris realiuoju laiku brai\u017eo FFT spektrus, matuoja amplitud\u0119 ir faz\u0119 ties 1&times; RPM bei susieja gedim\u0173 po\u017eymius, kad atskirt\u0173 disbalans\u0105, nesulygiavim\u0105, laisvum\u0105 ir guoli\u0173 pa\u017eeidimus &mdash; o tada to paties seanso metu atlieka balansavim\u0105. Vienas ne\u0161iojamasis komplektas u\u017e &euro;1,975 apima diagnostik\u0105, korekcij\u0105 ir patikr\u0105 be prietais\u0173 keitimo.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/lt\/balanset-1a\/\">Gaukite \"Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/lt\/community\/\">Paklauskite m\u016bs\u0173 in\u017einieriaus<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/02\/interface-1-e1518391488191.webp\" alt=\"Balanset-1A vibracij\u0173 analizatoriaus FFT spektro s\u0105saja ne\u0161iojamajame kompiuteryje\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Trumpai tariant:<\/b> Vibracijos analizatorius Balanset-1A vienu metu fiksuoja dviej\u0173 kanal\u0173 signalus i\u0161 dviej\u0173 vibracijos jutikli\u0173 (analogini\u0173 MEMS akselerometr\u0173), apskai\u010diuoja realaus laiko FFT spektr\u0105 ir rodo amplitud\u0119 bei faz\u0119 kiekvienoje veleno eil\u0117s harmonikoje. Disbalansas pasirodo kaip dominuojantis 1&times; RPM maksimumas; nesutapimas, kaip pakelti 2&times; ir 3&times; komponentai; atsirado guoli\u0173 defekt\u0173 kaip BPFO\/BPFI smail\u0117s ir \u0161onin\u0117s juostos; laisvumas kaip subharmonikos. Kadangi lauko balansavimui naudojama ta pati aparatin\u0117 \u012franga ir jutikliai, gedim\u0105 diagnozuojate, i\u0161taisote ir patikrinate rezultat\u0105 per vien\u0105 apsilankym\u0105 vietoje. &mdash; matuojate vibracijos greit\u012f nuo 0.2 iki 80&nbsp;mm\/s nuo 5 iki 1000&nbsp;Hz.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#when\">Kada analizuoti<\/a><br \/>\n<a href=\"#measures\">K\u0105 jis matuoja<\/a><br \/>\n<a href=\"#faults\">Gedim\u0173 diagnostika<\/a><br \/>\n<a href=\"#how\">How to use it<\/a><br \/>\n<a href=\"#standards\">Standartai<\/a><br \/>\n<a href=\"#device\">\"Balanset-1A<\/a><br \/>\n<a href=\"#screenshots\">Screenshots<\/a><br \/>\n<a href=\"#cases\">Tikri atvejai<\/a><br \/>\n<a href=\"#calc\">Skai\u010diuokl\u0117s<\/a><br \/>\n<a href=\"#faq\">DUK<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"when\">\n<h2>Po\u017eymiai, kad j\u016bs\u0173 ma\u0161inai reikia vibracij\u0173 analiz\u0117s, o ne tik matuoklio rodmens<\/h2>\n<p>Vienas bendras vibracijos skai\u010dius pasako, kad ka\u017ekas negerai. FFT spektras pasako kas ir kod\u0117l. \u0160ioms situacijoms reikia tikro analizatoriaus:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Ne\u017einoma vibracijos prie\u017eastis<\/b> Bendras lygis yra padid\u0117j\u0119s, ta\u010diau negalite nustatyti, ar kaltas disbalansas, nesulygiavimas, laisvumas ar guolio pa\u017eeidimas &mdash; FFT atskiria kiekvien\u0105 po\u017eym\u012f.<\/div>\n<div><b>Stipri 1&times; RPM komponent\u0117<\/b> Ry\u0161ka\u016bs pirmosios eil\u0117s smail\u0117s yra charakteringas likutinio rotoriaus disbalanso \u017eenklas ir prie\u017eastis prad\u0117ti balansuoti.<\/div>\n<div><b>Padidinti 2&times; arba 3&times; harmonikai<\/b> Ry\u0161ka\u016bs antrosios arba tre\u010diosios eil\u0117s komponentas da\u017eniausiai rodo sujungim\u0173 arba velen\u0173 kampin\u0119 arba lygiagret\u0119 nesukrypt\u012f.<\/div>\n<div><b>Subharmonikai arba pla\u010diaspektriniai triuk\u0161mai<\/b> \u017demo laipsnio guoli\u0173 defekt\u0173 da\u017eniai (BPFO, BPFI, BSF, FTF) ir j\u0173 harmonikos atsiranda grei\u010dio spektre, kai atsiranda defektas.<\/div>\n<div><b>Po remonto pri\u0117mimo patikra<\/b> Balansuojant, lyginant arba kei\u010diant guol\u012f, reikalingas i\u0161matuotas \u012frodymas, kad lygiai nukritus \u017eemiau ISO 20816 pri\u0117mimo ribos.<\/div>\n<div><b>Periodin\u0117 b\u016bkl\u0117s steb\u0117senos ap\u017evalga<\/b> Nustatant atskaitos spektrus reguliariais intervalais, galima steb\u0117ti did\u0117jan\u010dias amplitudes ir planuoti prie\u017ei\u016br\u0105 prie\u0161 neplanuot\u0105 sustojim\u0105.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"measures\">\n<h2>K\u0105 Balanset-1A analizatorius matuoja<\/h2>\n<p>Analizatorius vienu metu fiksuoja signalus i\u0161 dviej\u0173 tiekiam\u0173 vibracijos jutikli\u0173 (analogini\u0173 MEMS akselerometr\u0173), susiet\u0173 su lazeriniu tachometru. Kiekvienas toliau i\u0161vardytas parametras pasiekiamas atliekant vien\u0105 \u012fsigijimo paleidim\u0105:<\/p>\n<ul class=\"vbm-list\">\n<li>Bendra vibracijos greitis (mm\/s RMS) ir pagreitis (m\/s&sup2; arba g)<\/li>\n<li>Realaus laiko FFT da\u017enio spektras su naudotojo pasirenkama skiriam\u0105ja geba<\/li>\n<li>Vibracijos forma (laiko domeno signalas) abiejuose kanaluose vienu metu<\/li>\n<li>Faz\u0117s kampas 1&times; RPM at\u017evilgiu \u012f veleno tachometro atskaitos ta\u0161k\u0105<\/li>\n<li>1&times;, 2&times;, 3&times; ir auk\u0161tesn\u0117s veleno eil\u0117s amplitud\u0117s i\u0161trauktos i\u0161 FFT<\/li>\n<li>Sinchroninis dviej\u0173 kanal\u0173 surinkimas (abu guolio plok\u0161tumai vienu metu)<\/li>\n<li>Darbinis greitis (RPM) i\u0161 optinio lazerio tachometro &mdash; vardaplok\u0161t\u0117 nereikalinga<\/li>\n<li>Vibracijos tendencij\u0173 \u017eurnalas per nuoseklius matavimus<\/li>\n<li>Spausdintina ataskaita: forma, spektras ir skaitinis santrauka<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>up to &times;10<\/b><span>guoli\u0173 tarnavimo laikas, kai disbalanso apkrova suma\u017e\u0117ja perpus (ISO 281)<\/span><\/div>\n<div class=\"vbm-stat\"><b>-70%<\/b><span>b\u016bdinga vibracij\u0173 suma\u017e\u0117jimas po vieno balansavimo seanso<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>kanalai, vienalaik\u0117 akvizi\u0446\u0438\u0458\u0430<\/span><\/div>\n<div class=\"vbm-stat\"><b>5&ndash;1000&nbsp;Hz<\/b><span>analizatoriaus da\u017enio diapazonas<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"faults\">\n<h2>Gedim\u0173 diagnostika &mdash; FFT spektro skaitymas<\/h2>\n<p>Kiekvienas mechaninis gedimas palieka charaktering\u0105 spektrin\u012f atspaud\u0105. Toliau pateiktoje lentel\u0117je susieti da\u017eniausi gedim\u0173 tipai su j\u0173 spektrin\u0117mis charakteristikomis, kad gal\u0117tum\u0117te tiesiogiai i\u0161 Balanset-1A ekrano nuskaityti ma\u0161inos b\u016bkl\u0119.<\/p>\n<table class=\"vbm-table\">\n<caption>Vibracij\u0173 gedim\u0173 diagnostikos vadovas &mdash; spektrin\u0117s charakteristikos<\/caption>\n<thead>\n<tr>\n<th>Gedimas<\/th>\n<th>Dominuojantys spektriniai komponentai<\/th>\n<th>Kiti indikatoriai<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Rotoriaus disbalansas<\/b><\/td>\n<td>Stipri 1&times; RPM; visos kitos eil\u0117s \u017eemos<\/td>\n<td>Faz\u0117 stabili; amplitud\u0117 did\u0117ja proporcingai grei\u010dio kvadratui; patvirtinta bandymo mas\u0117s testu<\/td>\n<\/tr>\n<tr>\n<td><b>Kampinis nesutapimas<\/b><\/td>\n<td>Padid\u0117jusi 1&times; ir 2&times;; kartais 3&times;<\/td>\n<td>Aksialin\u0117 vibracija da\u017enai lygi radialinei arba j\u0105 vir\u0161ija; faz\u0117s skirtumas per sujungim\u0105 &asymp;180&deg;<\/td>\n<\/tr>\n<tr>\n<td><b>Lygiagretus a\u0161i\u0173 nesutapimas<\/b><\/td>\n<td>Stipri 2&times; RPM; 1&times; taip pat gali b\u016bti<\/td>\n<td>Auk\u0161ta radialin\u0117 vibracija; 180&deg; faz\u0117s poslinkis matuojamas per sujungim\u0105 radialine kryptimi<\/td>\n<\/tr>\n<tr>\n<td><b>Mechaninis laisvumas<\/b><\/td>\n<td>Subharmonin\u0117s (0,5&times;, 0,33&times;) ir daugybin\u0117s harmonikos iki 10&times;<\/td>\n<td>Plataus spektro triuk\u0161mo lygis padid\u0117j\u0119s; simptomai sunk\u0117ja esant apkrovai<\/td>\n<\/tr>\n<tr>\n<td><b>Riediminio elemento guolio nusid\u0117v\u0117jimas<\/b><\/td>\n<td>BPFO, BPFI, BSF arba FTF defekto da\u017eniai ir j\u0173 harmonikos<\/td>\n<td>Gali pasirodyti prie\u0161 bendrajam lygiui pakylus; \u0161alin\u0117s juostos aplink defekto da\u017enius patvirtina progresavim\u0105<\/td>\n<\/tr>\n<tr>\n<td><b>Rezonansas<\/b><\/td>\n<td>Didel\u0117 amplitud\u0117 \u0161alia nat\u016bralinio da\u017enio, da\u017enai nesinkroni\u0161ka su RPM<\/td>\n<td>Amplitud\u0117s smail\u0117s pasirodo tam tikru grei\u010diu; faz\u0117 pasislinka apie 180&deg; per rezonans\u0105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kai 1&times; komponentas dominuoja, tiesiogiai pereikite \u012f balansuojam\u0105j\u012f re\u017eim\u0105 &mdash; Balanset-1A t\u0105 pat\u012f matavimo b\u0117gim\u0105 naudoja kaip prad\u017ei\u0105 koeficiento \u012ftakos skai\u010diavimui, tod\u0117l laikas neei\u0161laipstytas.<\/p>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Kod\u0117l vienas bendrasis skai\u010dius nesuima klaidos<\/h2>\n<p>Vibracijos pie\u0161tukas arba paprastas RMS matuoklis susumuoja visus da\u017enio komponentus \u012f vien\u0105 skai\u010di\u0173. Du kompresoriai gali rodyti identi\u0161k\u0105 bendr\u0105 lyg\u012f, ta\u010diau i\u0161 esm\u0117s skirtingas klaidas &mdash; vienas dominuoja 1&times; disbalansavimo, kitas guolio defekt\u0173 \u0161aliniais. Be da\u017enio skyrimo j\u016bs tiesiog sp\u0117liojate prie\u017east\u012f ir rizikuojate taikyti klaiding\u0105 gydym\u0105. FFT i\u0161sklaido signal\u0105, kad kiekvienas klaidos tipas b\u016bt\u0173 rodomas kaip \u017eym\u0117ta smail\u0117 savoje charakteringoje da\u017enyje, suteikdama jums tiek diagnoz\u0119, tiek rekomendacij\u0105 tame pa\u010diame matavime.<\/p>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> parodo, kod\u0117l diagnoz\u0117 yra svarbi finansi\u0161kai. Ried\u0117jimo guolio pagrindinis \u012fvertinimo laikas yra <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b> (milijonais apsisukim\u0173), kur P yra lygiavert\u0117 dinamin\u0117 guolio apkrova ir p = 3 rutuliniams guoliams (10\/3 ritininiams guoliams). Lik\u0119s disbalansas prie \u0161ios apkrovos prideda besisukant\u012f komponent\u0105, tod\u0117l perpus suma\u017einus 1&times; vibracijos amplitud\u0119, disbalanso apkrova suma\u017e\u0117ja ma\u017edaug perpus; kur \u0161i besisukanti apkrova dominuoja P, guolio tarnavimo laikas padaug\u0117ja iki 2<sup>p<\/sup>: apie <b>8\u00d7 rutuliniams guoliams ir ~10\u00d7 ritininiams guoliams<\/b>. \u012evertinimas galioja tik tada, kai i\u0161matuota 1&times; vibracija yra pagr\u012fstas besisukan\u010dios dinamin\u0117s guolio apkrovos rodiklis. Naudokite <a href=\"https:\/\/vibromera.eu\/lt\/calculators\/bearing-load\/\">guolio tarnavimo laiko skai\u010diuokl\u0117<\/a> j\u016bs\u0173 ma\u0161inos santaupoms skai\u010diuoti.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>Kaip naudoti Balanset-1A kaip vibracijos analizatori\u0173 &mdash; \u017eingsnis po \u017eingsnio<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Pritvirtinkite jutiklius.<\/b> Pritvirtinkite vien\u0105 arba abu vibracijos jutiklius prie guoli\u0173 korpus\u0173 naudodami magnetinius laikiklius. Nor\u0117dami atlikti faz\u0117s atskaitos analiz\u0119, pritvirtinkite lazerin\u012f tachometr\u0105 atspindin\u010di\u0105 juostel\u0119 prie besisukan\u010dio veleno ir nukreipkite jutikl\u012f \u012f j\u0105 (50&ndash;500&nbsp;mm darbinis diapazonas). Abu kanalai \u012fra\u0161o vienu metu.<\/li>\n<li><b>Paleiskite rotori\u0173 ir susigrupaite.<\/b> Atverkite Balanset programin\u0119 \u012frang\u0105, pasirinkite <em>Analyzer<\/em> re\u017eim\u0105 ir prad\u0117kite susigr\u016bpavim\u0105. Programin\u0117 \u012franga realiu laiku rodo tiesiogin\u0119 bangos form\u0105, FFT spektr\u0105 ir bendr\u0105 RMS vibracijos lyg\u012f mm\/s standartiniame Windows ne\u0161iojamajame kompiuteryje.<\/li>\n<li><b>Perskaitykite spektr\u0105.<\/b> Nustatykite dominuojan\u010dias da\u017enio smail\u0117s. Pirmosios eil\u0117s amplitud\u0117 ir faz\u0117 automati\u0161kai rodomos prie\u0161 taho impuls\u0105. \u017di\u016br\u0117kite auk\u0161\u010diau esan\u010di\u0105 klaid\u0173 lentel\u0119, kad spektrin\u012f model\u012f suderintum\u0117te su labiausiai tik\u0117tinu klaid\u0173 tipu.<\/li>\n<li><b>Palyginkite su pri\u0117mimo ribomis.<\/b> Patikrinkite bendr\u0105 grei\u010dio skaitymo rib\u0105 prie\u0161 atitinkam\u0105 <b>ISO 20816<\/b> zonos rib\u0105 (A\/B\/C\/D) j\u016bs\u0173 ma\u0161inos klasei ir energijos jung\u010diai. Eksportuokite spektro grafik\u0105 ir skaitines reik\u0161mes prie\u017ei\u016bros ataskaitai.<\/li>\n<li><b>Jei disbalansavimas patvirtintas, balansuokite toje pa\u010dioje sesijoje.<\/b> Pradinis matavimas jau buvo sukauptas ir naudojamas kaip pirmasis b\u0117gimas koeficiento \u012ftakos sekoje. Prid\u0117kite bandom\u0105j\u012f svor\u012f, v\u0117l paleiskite ir leiskite programinei \u012frangai apskai\u010diuoti patais\u0105 &mdash; joki\u0173 papildom\u0173 instrument\u0173, jokio antrojo aplank\u0173.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Vibracijos matavimo standartai<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 20816<\/b> apibr\u0117\u017eia vertinimo zonas vibracijos grei\u010diui (mm\/s RMS) nejudan\u010diose dalyse: A zona (naujai paleista), B (priimtina ilgalaikei eksploatacijai), C (signalas &mdash; reikalingas nedelstinas tyrimas), D (pavojus &mdash; \u017eala ma\u0161inai gresia). Ribos kinta priklausomai nuo ma\u0161inos klas\u0117s ir veleno centro auk\u0161\u010dio. Balanset-1A rodo bendr\u0105 greit\u012f mm\/s RMS, tod\u0117l galite tiesiogiai palyginti su atitinkama ISO 20816 dalimi savo ma\u0161inos tipui.<\/p>\n<p>Nusta\u010dius disbalanso problem\u0105, likusias disbalanso problemas po balansavimo vertina <b>ISO 21940-11<\/b> G-klas\u0117s (G0.4 iki G40). Balanset-1A dokumentuoja pasiektos likusios disbalanso problemos dyd\u012f spausdintinoje ataskaitoje, suteikdama jums patikrint\u0105 \u012fra\u0161\u0105 pagal taikom\u0105 standart\u0105. Naudokite <a href=\"https:\/\/vibromera.eu\/lt\/calculators\/residual-unbalance-iso1940\/\">liku\u010di\u0173 ir disbalanso skai\u010diuokl\u0117<\/a> prie\u0161 prad\u0117dami darb\u0105 su\u017einokite leistin\u0105 nuokryp\u012f.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A &mdash; j\u016bs\u0173 visapusi\u0161kas lauko analizatorius ir balansavimo rinkinys<\/h2>\n<p>Viskas \u0161iame puslapyje atlikta naudojant vien\u0105 ne\u0161iojam\u0105j\u0105 priemon\u0119 - <a href=\"https:\/\/vibromera.eu\/lt\/balanset-1a\/\">Balanset-1A<\/a>. Tai dviej\u0173 kanal\u0173 dinaminis balanseris ir vibracijos analizatorius, diagnozuojantis gedimus i\u0161 FFT spektro ir, kai nustatytas disbalansas, balansuoja stand\u017eius rotori\u0173 <strong>savo guoliuose, esant darbiniam grei\u010diui.<\/strong>, taikant 3 pakop\u0173 \u012ftakos koeficiento metod\u0105 - programin\u0117 \u012franga apskai\u010diuoja tiksli\u0105 korekcin\u0119 mas\u0119 ir kamp\u0105 ir i\u0161saugo ataskait\u0105.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Pilnas Balanset-1A balansavimo rinkinys su jutikliais, lazeriniu tachometru, svarstykl\u0117mis ir d\u0117klu\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Kas yra visame rinkinyje<\/h3>\n<p class=\"price\">&euro;1,975 <span>- Pilnas komplektas, yra sand\u0117lyje, PVM s\u0105skaita fakt\u016bra<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>S\u0105sajos matavimo blokas (USB, 2 kanalai)<\/li>\n<li>Du vibracijos akselerometrai (4 m kabelis, 10 m - pasirinktinai)<\/li>\n<li>Lazerinis tachometras \/ optinis faz\u0117s jutiklis (50-500 mm)<\/li>\n<li>Magnetinis jutiklio stovas<\/li>\n<li>Skaitmenin\u0117s svarstykl\u0117s bandomiesiems ir korekciniams svoriams<\/li>\n<li>\"Windows\" balansavimo ir analiz\u0117s programin\u0117 \u012franga<\/li>\n<li>Plastikinis transportavimo d\u0117klas<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/lt\/balanset-1a\/\">Per\u017ei\u016br\u0117ti \"Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/lt\/community\/\">Paklauskite m\u016bs\u0173 in\u017einieriaus<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Rekomenduojama<\/span><\/p>\n<h3>Pilnas rinkinys<\/h3>\n<p>\u012erenginys &middot; 2 sensoriai &middot; lazerio tachometras &middot; magnetinis stovas &middot; skaitmen\u0117s svarstykl\u0117s &middot; programin\u0117 \u012franga &middot; transportavimo d\u0117\u017e\u0117. Viskas, ko reikia norint prad\u0117ti analizuoti ir balansuoti i\u0161 karto.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>OEM rinkinys<\/h3>\n<p>\u012erenginys - 2 jutikliai - lazerinis tachometras - programin\u0117 \u012franga. Skirta integratoriams, kurie jau turi stend\u0105, svarstykles ir d\u0117kl\u0105 arba kurie \u012fmontuoja \u012frengin\u012f \u012f balansavimo stakles.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Pagrindin\u0117s technin\u0117s specifikacijos<\/caption>\n<thead>\n<tr>\n<th>Parametras<\/th>\n<th>Vert\u0117<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Matavimo kanalai<\/td>\n<td>2 (vienos ir dviej\u0173 plok\u0161tum\u0173 balansavimas)<\/td>\n<\/tr>\n<tr>\n<td>Vibracijos grei\u010dio diapazonas<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Da\u017eni\u0173 diapazonas<\/td>\n<td>5&ndash;1000 Hz (&le;10 % amplitud\u0117s paklaida vir\u0161 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>Matavimo tikslumas<\/td>\n<td>\u00b15% visos skal\u0117s<\/td>\n<\/tr>\n<tr>\n<td>Metodas<\/td>\n<td>3 eigos \u012ftakos koeficientas (1 arba 2 plok\u0161tumos)<\/td>\n<\/tr>\n<tr>\n<td>Analiz\u0117<\/td>\n<td>Amplitud\u0117 ir faz\u0117 1\u00d7, FFT spektras ir bangos forma, i\u0161saugotos ataskaitos<\/td>\n<\/tr>\n<tr>\n<td>Ne\u0161iojamasis kompiuteris<\/td>\n<td>Ne\u012ftraukta (Windows PC, galima \u012fsigyti pagal pageidavim\u0105)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>\u2713<\/b> Yra sand\u0117lyje<\/span><span><b>\u2713<\/b> DHL Portugalija 35 \u20ac<\/span><span><b>\u2713<\/b> DHL visame pasaulyje 110 \u20ac<\/span><span><b>\u2713<\/b> 2 met\u0173 garantija<\/span><span><b>\u2713<\/b> PVM s\u0105skaita fakt\u016bra<\/span><span><b>\u2713<\/b> In\u017einieriaus pagalba<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"screenshots\">\n<h2>K\u0105 rodo Balanset-1A analizatorius<\/h2>\n<div class=\"vbm-cases\">\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/ChatGPT-Image-25-%D0%B8%D1%8E%D0%BB.-2025-%D0%B3.-22_07_35.webp\" alt=\"Balanset-1A dviej\u0173 kanal\u0173 vibracij\u0173 analizatoriaus ap\u017evalgos ekranas\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dviej\u0173 kanal\u0173 analizatoriaus ap\u017evalga<\/h3>\n<p>Bendrasis vibracijos lygis, FFT spektras ir faz\u0117s kampas i\u0161 dviej\u0173 sensori\u0173 rodomi vienu metu vienoje Windows ne\u0161iojamoje kompiuteriu.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/09\/Screenshot-2025-07-29-165701-scaled.webp\" alt=\"Realaus laiko FFT spektras, rodantis da\u017eni\u0173 smailes gedim\u0173 diagnostikai\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Tikralaikis FFT spektras<\/h3>\n<p>Da\u017enio smail\u0117s atskiria disbalans\u0105 (dominuojantis 1&times;) nuo nelygiatvarkos (2&times;) ir guolio defekto \u0161onini\u0173 juost\u0173.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/%D0%98%D0%B7%D0%BE%D0%B1%D1%80%D0%B0%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-WhatsApp-2025-10-03-%D0%B2-11.16.33_1bc14f9b.webp\" alt=\"Akselerometras ir lazerinis tachometras, sumontuoti ant guolio korpuso lauke\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Matavimai lauke<\/h3>\n<p>Vibracijos jutiklis ir lazerinis tachometras sumontuoti ant veikian\u010dios ma\u0161inos&rsquo;s guolio korpusas &mdash; ma\u0161inos i\u0161ardyti nereikia.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10461221.webp\" alt=\"Balanset programin\u0117je \u012frangoje rodoma amplitud\u0117 ir faz\u0117 ties 1x RPM\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Amplitud\u0117 ir faz\u0117 1&times; da\u017enyje<\/h3>\n<p>Pirmos eil\u0117s amplitud\u0117 ir faz\u0117s kampas rodomi tachometro atskaitos at\u017evilgiu &mdash; reikalingi \u012fvestys \u012ftakos koeficiento balansavimui.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10418068.webp\" alt=\"Spausdinama Balanset-1A matavimo ataskaita su bangos forma ir spektru\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dokumentuota ataskaita<\/h3>\n<p>Bangos forma, FFT spektras ir skaitin\u0117 santrauka eksportuoti kaip spausdintina ataskaita prie\u017ei\u016bros \u012fra\u0161ui.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Real\u016bs matavimai ir analizatoriaus atvejai<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/lt\/pavyzdys\/santykines-rotoriaus-vibracijos-matavimas-naudojant-bekontakcius-linijinius-poslinkio-jutiklius\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/image014.webp\" alt=\"Bekontaktis vibracijos matavimas linijiniais poslinkio jutikliais\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Nesuly\u010diusi vibracijos matavimas<\/h3>\n<p>Tiesiogini\u0173 i\u0161st\u016bmio jutikli\u0173 naudojimas santykiniam rotoriaus vibracijai matuoti be a\u0161ies s\u0105ly\u010dio &mdash; tinka rotoliams, kuriuose akselerometro tvirtinimas neprakti\u0161kas.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/lt\/pavyzdys\/nesiojamasis-balansavimo-vibracijos-analizatorius-ir-balansavimo-masinos-balansavimo-suvestine-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/photo_2023-04-08_17-03-49-1024x576.webp\" alt=\"Balanset-1A naudojamas ir kaip vibracij\u0173 analizatorius, ir kaip dviej\u0173 plok\u0161tum\u0173 balansavimo \u012frenginys\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Analizatorius ir balansavimo priemon\u0117 sujungti<\/h3>\n<p>Praktinis rodymimas, kaip vienas \u012ftaisas vieno darbo metu apima vibracij\u0173 analiz\u0119 ir dviej\u0173 plok\u0161tum\u0173 balansavim\u0105, nuo diagnoz\u0117s iki patikrintos korekcijos.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/lt\/pavyzdys\/why-balancing-doesnt-reduce-vibration-troubleshooting-guide-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/06\/ChatGPT-Image-19-%D0%B8%D1%8E%D0%BD.-2025-%D0%B3.-18_31_25.webp\" alt=\"Naudojant analizatori\u0173 diagnozuojama, kod\u0117l balansavimas nema\u017eina vibracijos\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Diagnozuokite prie\u0161 balansavim\u0105<\/h3>\n<p>\u0160alinimo vadovas atvejams, kai balansavimas vienas nepavyksta suma\u017einti vibracij\u0105 &mdash; ir kaip FFT spektras atskleid\u017eia tikr\u0105j\u0105 pagrindin\u0119 prie\u017east\u012f.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Nemokami vibracij\u0173 skai\u010diuotuvai<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/lt\/calculators\/bearing-load\/\">Guoli\u0173 tarnavimo laiko skai\u010diuokl\u0117<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lt\/calculators\/centrifugal-force-unbalance\/\">I\u0161centrin\u0117 j\u0117ga d\u0117l disbalanso<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lt\/calculators\/residual-unbalance-iso1940\/\">Likutinis disbalansas (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lt\/calculators\/trial-weight-calculator\/\">Bandomojo svorio skai\u010diuokl\u0117<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>Vibracij\u0173 analizatoriaus DUK<\/h2>\n<details>\n<summary>Kaip FFT analiz\u0117 atskiria disbalans\u0105 nuo netinkamo i\u0161lyginimo?<\/summary>\n<div class=\"ans\">Disbalsansas sukuria vien\u0105 dominuojant\u012f smail\u0119 tiksliai ties 1&times; velen\u0173 apsisukimo da\u017eniu. Kampinis nepakankamas i\u0161lyginimas paprastai parodo stipr\u0173 2&times; komponent\u0105 ir kartais 3&times;, da\u017enai su padidinta aksiali\u0105ja vibracija. Lygiagretus nepakankamas i\u0161lyginimas sukuria ry\u0161k\u0173 2&times; radialin\u012f smail\u0119. Balanset-1A \u0161ias smailes automati\u0161kai \u017eymi FFT ekrane, tod\u0117l prie\u0161 nutariant d\u0117l korekcijos galite identifikuoti dominuojant\u012f gedim\u0105. Jei 1&times; komponentas dominuoja, t\u0105 pa\u010di\u0105 matavimo eig\u0105 galima tiesiogiai perkelti \u012f balansavimo skai\u010diavim\u0105.<\/div>\n<\/details>\n<details>\n<summary>Ar galiu naudoti Balanset-1A kaip atskiros analizatori\u0173 be balansavimo?<\/summary>\n<div class=\"ans\">Taip. \u012etaisas veikia tik analizatoriaus re\u017eimu, skirtu vibracij\u0173 spektrams \u012fra\u0161yti, i\u0161matuoti bendrus lygius mm\/s, ir duomenims registruoti d\u0117l b\u016bkl\u0117s monitoringo tendencij\u0173 &mdash; be balansavimo re\u017eimo \u012fvedimo. Tai naudinga gaunamo patikrinimui, periodiniam b\u016bkl\u0117s ap\u017evalgoms ir po remonto pri\u0117mimo matavimams pagal ISO 20816 ribas.<\/div>\n<\/details>\n<details>\n<summary>Kok\u012f da\u017eni\u0173 diapazon\u0105 apima FFT, ir ar to pakanka guolio diagnostikai?<\/summary>\n<div class=\"ans\">Balanset-1A apima nuo 5 iki 1000 &nbsp;ZHz, kuris fiksuoja visas veleno eil\u0117s harmonikas ir pagrindinius guoli\u0173 defekt\u0173 da\u017enius (BPFO, BPFI, BSF, FTF) ir j\u0173 \u017eemesnes harmonikas daugeliui pramonini\u0173 ried\u0117jimo element\u0173 guoli\u0173 esant tipiniams grei\u010diams. Ta\u010diau atkreipkite d\u0117mes\u012f \u012f rib\u0105: ankstyvos stadijos guoli\u0173 pa\u017eeidimai paprastai aptinkami naudojant auk\u0161to da\u017enio pagrei\u010dio ir gaubtin\u0117s (demoduliacijos) metodus, kuriems reikalingas pralaidumas nuo keli\u0173 kHz iki de\u0161im\u010di\u0173 kHz &mdash; u\u017e \u0161io prietaiso&rsquo; diapazono rib\u0173. 5&ndash;1000&nbsp;ZHz Balanset-1A rodo guoli\u0173 gedimus, kai jie sukuria i\u0161matuojamus grei\u010dio komponentus esant defekt\u0173 da\u017eniams, t. y. labiau i\u0161vystytame etape; tai n\u0117ra specialios pla\u010diajuos\u010dio guoli\u0173 diagnostikos priemon\u0117s pakaitalas.<\/div>\n<\/details>\n<details>\n<summary>Ar ISO 20816 taikytina mano ma\u0161inai?<\/summary>\n<div class=\"ans\">ISO 20816 apima plat\u0173 rotorini\u0173 ma\u0161in\u0173 spektr\u0105 per jos kelis dalies: siurblius, kompresorius, ventiliatorius, turbinas, variklius ir generatorius &mdash; visi apra\u0161yti. Konkreti zonos riba priklauso nuo ma\u0161inos galios klas\u0117s ir a\u0161ies centro auk\u0161\u010dio. Balanset-1A prane\u0161a bendr\u0105 greit\u012f mm\/s RMS, tod\u0117l t\u0105 ISO 20816 dal\u012f, kuri apima j\u016bs\u0173 ma\u0161inos tip\u0105, galite tiesiogiai pritaikyti skaitymasinimui.<\/div>\n<\/details>\n<details>\n<summary>Ar faz\u0117s matavimas pakankamai tikslus dviej\u0173 plok\u0161tum\u0173 balansavimui?<\/summary>\n<div class=\"ans\">Taip. Faz\u0117 matuojama atsi\u017evelgiant \u012f optinio sukimosi indikatoraus impuls\u0105, suteikiant kartojam\u0105 kampin\u012f etalon\u0105. Dviej\u0173 kanal\u0173 vienu metu vykdoma akvizi\u0446\u0438\u0458\u0430 u\u017etikrina, kad abi guolio plok\u0161tumos b\u016bt\u0173 atoringos ties ta pa\u010dia a\u0161ies pad\u0117timi, o tai yra kriti\u0161kai svarbu dviej\u0173 plok\u0161tum\u0173 dinamin\u0117s balansavimo darb\u0173 \u012ftakos koeficientams tiksliai skai\u010diuoti.<\/div>\n<\/details>\n<details>\n<summary>Kaip analizatorius padeda, kai balansavimas vienas nefiksavo vibracij\u0105?<\/summary>\n<div class=\"ans\">Kai balansavimas suma\u017eina 1&times; komponent\u0105, bet bendra vibracija lieka didel\u0117, FFT i\u0161 karto parodo, kuris kitas da\u017enio komponentas tapo dominuojantis &mdash; ar tai 2&times; nepakankamo i\u0161lyginimo harmonika, guolio gedimo da\u017enis ar subharmoninis sulaistymo signat\u016bra. Tai tikriausiai nukreipia sekant\u012f koresektyv\u0173 \u017eingsn\u012f tiksliai nei paliekant technikus atsp\u0117ti. \u017dr. m\u016bs\u0173 atvejo studij\u0105 apie i\u0161liekamos vibracij\u0173 diagnozavim\u0105, kad gautum\u0117te praktinius pavyzd\u017eius.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Su\u017einokite teorij\u0105<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/lt\/glossary\/lauko-balansavimas\/\">Lauko balansavimas<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lt\/glossary\/residual-unbalance\/\">Likutinis disbalansas<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lt\/glossary\/balance-quality\/\">Subalansuotos kokyb\u0117s klas\u0117s<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lt\/glossary\/dynamic-balancing\/\">Dinaminis balansavimas<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Diagnozuokite pirmiausia &mdash; tada balansavokite su pasitik\u0117jimu<\/h2>\n<p>Balanset-1A suteikia jums dviej\u0173 kanal\u0173 FFT analizatori\u0173 ir dviej\u0173 plok\u0161tum\u0173 balansuokl\u012f viename ne\u0161iojamajame komplekte. Perskaitykite gedim\u0105 i\u0161 spektro, i\u0161taisykite j\u012f prie \u0161altinio ir patikrinkite pagal ISO 20816 &mdash; visa tai per vien\u0105 apsilankym\u0105 vietoje u\u017e &euro;1,975.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/lt\/balanset-1a\/\">Per\u017ei\u016br\u0117ti \"Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/lt\/community\/\">U\u017eduoti klausim\u0105 forume<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Vibration Analyzer Vibration Analyzer &mdash; Two-Channel FFT Spectrum, Phase &amp; Fault Diagnostics The Balanset-1A is a two-channel vibration analyzer that plots real-time FFT spectra, measures amplitude and phase at 1&times; RPM, and maps fault signatures to distinguish unbalance, misalignment, looseness and bearing damage &mdash; then balances in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101581","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/pages\/101581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/comments?post=101581"}],"version-history":[{"count":6,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/pages\/101581\/revisions"}],"predecessor-version":[{"id":102102,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/pages\/101581\/revisions\/102102"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/media?parent=101581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}