{"id":4285,"date":"2024-06-03T20:39:05","date_gmt":"2024-06-03T20:39:05","guid":{"rendered":"https:\/\/vibromera.eu\/?p=4285"},"modified":"2026-07-03T10:54:37","modified_gmt":"2026-07-03T10:54:37","slug":"two-remarks-on-the-reasonableness-of-customer-requirements-for-balancing-machine-manufacturers","status":"publish","type":"post","link":"https:\/\/vibromera.eu\/lt\/content\/two-remarks-on-the-reasonableness-of-customer-requirements-for-balancing-machine-manufacturers\/","title":{"rendered":"Dvi pastabos d\u0117l balansavimo ma\u0161in\u0173 gamintojams keliam\u0173 klient\u0173 reikalavim\u0173 pagr\u012fstumo"},"content":{"rendered":"<h1>Dvi pastabos d\u0117l balansavimo ma\u0161in\u0173 gamintojams keliam\u0173 klient\u0173 reikalavim\u0173 pagr\u012fstumo<\/h1>\n<h2>\u012evadas<\/h2>\n<p>Per pastaruosius pusantr\u0173 met\u0173 m\u016bs\u0173 \u012fmon\u0117 gavo daugiau nei 30 u\u017eklaus\u0173 d\u0117l \u012fvairi\u0173 tip\u0173 <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/balancing-machine\/\">balansavimo stakl\u0117s<\/a>. I\u0161nagrin\u0117jus prie \u0161i\u0173 u\u017eklaus\u0173 prid\u0117tas technines specifikacijas paai\u0161k\u0117ja, kad daugumoje j\u0173 yra numatyta nema\u017eai reikalavim\u0173, kurie daro didel\u0119 \u012ftak\u0105 ma\u0161in\u0173 gamybos terminams ir s\u0105naudoms, be to, smarkiai suma\u017eina galim\u0173 tiek\u0117j\u0173 skai\u010di\u0173. Tarp j\u0173 ypa\u010d i\u0161siskiria du reikalavimai:<\/p>\n<ul>\n<li>Reikalavimas u\u017etikrinti, kad <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/residual-unbalance\/\">likutinis disbalansas<\/a>, kuris netur\u0117t\u0173 vir\u0161yti 0,1 g*mm\/kg (\u00b5m).<\/li>\n<li>Reikalavimas \u012ftraukti balansavimo stakles \u012f Matavimo priemoni\u0173 registr\u0105.<\/li>\n<\/ul>\n<p>I\u0161analizuokime \u0161i\u0173 reikalavim\u0173 \u012fgyvendinimo pagr\u012fstum\u0105 ir \u012fmanomum\u0105 i\u0161 realaus vartotojo perspektyvos.<\/p>\n<h2>1. Ma\u0161inai keliam\u0173 tikslumo reikalavim\u0173 analiz\u0117<\/h2>\n<p>Patikrinsime kliento tikslumo reikalavim\u0173 pagr\u012fstum\u0105 naudodamiesi balansavimo stakli\u0173, skirt\u0173 balansuoti elektros varikli\u0173, turbokompresori\u0173 ir kompresori\u0173 rotorius, sverian\u010dius nuo 10 iki 1500 kg, technine specifikacija. Specifikacijoje nustatyta savitojo likutinio disbalanso leistinoji nuokrypa, kuri, pasak u\u017esakovo, netur\u0117t\u0173 vir\u0161yti 0,1 g*mm\/kg.<\/p>\n<p>Nor\u0117dami patikrinti, ar \u0161is reikalavimas \u012fvykdytas, remiam\u0117s 1 lentele <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/iso-1940-1\/\">ISO 1940-1<\/a> \u201eMechaniniai virpesiai \u2013 Rotori\u0173 balansavimo kokyb\u0117s reikalavimai.\u201c Remdamiesi \u0161ioje lentel\u0117je pateiktomis rekomendacijomis, darome prielaid\u0105, kad balansavimo tikslumas <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/rotorius\/\">rotoriai<\/a> elektros varikli\u0173, turbokompresori\u0173 ir kompresori\u0173, kuriuos turi u\u017etikrinti u\u017esakyta ma\u0161ina, turi atitikti G2.5 kokyb\u0117s reikalavimus <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/g-grade\/\">klas\u0117<\/a>. Darant prielaid\u0105, kad numatomas subalansuoto rotoriaus darbinis sukimosi da\u017enis yra, pavyzd\u017eiui, 200 Hz (kas su didele atsarga apima daugumos \u017einom\u0173 ma\u0161in\u0173 sukimosi da\u017enius), galime lengvai apskai\u010diuoti leistin\u0105 liekam\u0105j\u012f savit\u0105j\u012f disbalans\u0105 statiniam (vienos plok\u0161tumos) balansavimui, naudodami standarto 5 formul\u0119: eper = 2500 \/ (6,28 * 200) = 1,99 g*mm\/kg.<\/p>\n<p>Kardaninio veleno i\u0161mu\u0161imas, \u012flenkimai, tr\u016bkumai d\u0117l suvirinimo svori\u0173, purvo sankaupos <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/iso-21940-11\/\">ISO 21940-11<\/a>), kaip nurodyta 7 skyriuje, dviej\u0173 atram\u0173 asimetrinio rotoriaus leistina vert\u0117, nustatyta atliekant dinamin\u012f balansavim\u0105, tur\u0117t\u0173 b\u016bti ne ma\u017eesn\u0117 kaip 0,3 * eper, o tai m\u016bs\u0173 atveju sudaryt\u0173 0,6 g*mm\/kg, o ne 0,1 g*mm\/kg, kaip buvo reikalaujama pradin\u0117je technin\u0117je specifikacijoje. \u0160is leistinos vert\u0117s <a href=\"https:\/\/vibromera.eu\/lt\/glossary\/balancing-tolerance\/\">balansavimo tolerancija<\/a> atstum\u0105 tarp dviej\u0173 koregavimo plok\u0161tum\u0173 galima patikrinti naudojant m\u016bs\u0173 <a href=\"https:\/\/vibromera.eu\/lt\/calculators\/residual-unbalance-iso1940\/\">Likutinio disbalanso skai\u010diuokl\u0117 (ISO 21940-11)<\/a>.<\/p>\n<p>Kitaip tariant, kaip rodo m\u016bs\u0173 atlikta analiz\u0117, \u0161ioje technin\u0117je specifikacijoje (ir daugelyje kit\u0173 pana\u0161i\u0173 dokument\u0173) nustatyti balansavimo stakli\u0173 tikslumo reikalavimai yra ai\u0161kiai pertekliniai. Prakti\u0161kai \u012fgyvendindamas \u0161iuos perteklinius reikalavimus gamintojas sprend\u017eia rimtus projektavimo ir technologinius u\u017edavinius, paprastai kylan\u010dius gaminant itin didelio tikslumo ma\u0161inas, o tai neabejotinai turi \u012ftakos ma\u0161in\u0173 kainai ir gamybos trukmei. Be to, \u0161ie reikalavimai ne visada yra techni\u0161kai \u012fgyvendinami.<\/p>\n<p>Taip pat svarbu pa\u017eym\u0117ti, kad veiksmingam toki\u0173 didelio tikslumo ma\u0161in\u0173 darbui potencialiam klientui gali tekti \u012fvykdyti kelet\u0105 papildom\u0173 s\u0105lyg\u0173, pavyzd\u017eiui, \u012frengti termostabilias ir \u0161varias patalpas, vibracij\u0105 izoliuojan\u010dius pamatus ir pan., kuri\u0173 suk\u016brimo s\u0105naudos gali net vir\u0161yti pa\u010dios ma\u0161inos \u012fsigijimo i\u0161laidas. Atsakant \u012f galim\u0105 kliento atstovo (min\u0117tos technin\u0117s specifikacijos autoriaus) prie\u0161taravim\u0105, kad \u012fvykd\u017eius \u0161\u012f reikalavim\u0105 ma\u0161inoje galima pasiekti gerokai ma\u017eesn\u012f likutin\u012f disbalans\u0105, i\u0161 tikr\u0173j\u0173 atitinkant\u012f G0.4 klas\u0119, galima rekomenduoti susipa\u017einti su GOST 22061-76 rekomendacijomis \u201eMa\u0161inos ir technologin\u0117 \u012franga. Balansavimo kokyb\u0117s klasi\u0173 sistema. Pagrindin\u0117s nuostatos\u201c (nacionalinis standartas, kurio \u0161iuolaikinis tarptautinis atitikmuo yra ISO 21940-11, anks\u010diau ISO 1940-1), galiojusiu iki ISO 1940-1 \u012fvedimo.<\/p>\n<p>\u0160io standarto, kur\u012f pareng\u0117 geriausi Soviet\u0173 S\u0105jungos balansavimo srities specialistai, 3 skyriuje pagr\u012fstai teigiama:<\/p>\n<ol>\n<li>Gaminiai, priskirti 1-ajai balansavimo kokyb\u0117s klasei (G0.4 klas\u0117 pagal ISO 1940-1), turi b\u016bti balansuojami savo guoliuose, savo korpuse, visomis darbo s\u0105lygomis, naudojant savo pavar\u0105.<\/li>\n<li>2-ai balansavimo kokyb\u0117s klasei (G1.0 klas\u0117) priskiriam\u0173 gamini\u0173 rotoriai tur\u0117t\u0173 b\u016bti balansuojami nuosavuose guoliuose arba nuosavame korpuse su specialia pavara, jei nuosavos pavaros n\u0117ra.<\/li>\n<li>Produkt\u0173, priskiriam\u0173 3-11 balansavimo kokyb\u0117s klas\u0117ms (G2.5-G4000 klas\u0117s), rotorius leid\u017eiama balansuoti kaip dalis arba surinkimo vienetus.<\/li>\n<\/ol>\n<p>\u0160i\u0173 rekomendacij\u0173 esm\u0117 yra ta, kad balansavimo stakl\u0117se siekti G0,4 ir G1,0 balansavimo kokyb\u0117s klasi\u0173 da\u017enai yra techni\u0161kai ir ekonomi\u0161kai beprasmi\u0161ka. Sumontavus rotorius \u012f ma\u0161in\u0105, pasiektas tikslumas prarandamas, o norint j\u012f atkurti, reikia papildomai perbalansuoti rotoriaus mazg\u0105 (savo guoliuose ir su savo pavara), atliekant tai ne\u0161iojama vibracine balansavimo \u012franga.<\/p>\n<p>Kaip iliustracin\u012f \u0161ios tez\u0117s pavyzd\u012f galime apsvarstyti \u0161lifavimo rato, skirto naudoti didelio tikslumo cilindriniame \u0161lifavimo stakli\u0173 \u012frenginyje (tikslumo klas\u0117 &#8220;C&#8221;), balansavim\u0105. Pagal anks\u010diau min\u0117tos ISO 1940-1 1 lentel\u0117s reikalavimus, \u0161lifavimo rato balansavimo kokyb\u0117 turi bent jau atitikti G0.4 klas\u0119. Atsi\u017evelgdami \u012f tai, kad numatomas \u0161lifavimo rato sukimosi da\u017enis darbo metu bus 6000 rpm (100 Hz), pagal gerai \u017einom\u0105 ISO 1940-1 7 formul\u0119 nustatome leistin\u0105 likutin\u012f specifin\u012f disbalans\u0105 eper, kuris bus 0.64 g*mm\/kg.<\/p>\n<p>Kitaip tariant, po balansavimo balansavimo stakl\u0117mis, u\u017etikrinant \u0161i\u0105 tolerancij\u0105, \u0161lifavimo rato mas\u0117s centro poslinkis technologin\u0117s a\u0161ies (balansavimo stakli\u0173 \u012ftvaro a\u0161ies) at\u017evilgiu neturi vir\u0161yti 0.64 \u00b5m. Kadangi pagal nacionalin\u012f standart\u0105 GOST 11654-90 &#8220;C&#8221; klas\u0117s \u0161lifavimo stakli\u0173 \u0161pindelio leid\u017eiamas radialinis mu\u0161imas yra 2 \u00b5m, sumontavus ant jo m\u016bs\u0173 \u0161lifavimo rat\u0105 (perbazuojant rat\u0105 nuo technologin\u0117s a\u0161ies \u012f darbin\u0119 a\u0161\u012f), liekamasis savitasis disbalansas gali gerokai padid\u0117ti ir ma\u017eiausiai tris kartus vir\u0161yti ISO 1940-1 rekomenduojam\u0105 tolerancij\u0105. Tokiais ir kitais pana\u0161iais atvejais, kaip min\u0117ta anks\u010diau, reikia papildomo balansavimo, kad b\u016bt\u0173 kompensuotos surinkimo etape atsirandan\u010dios paklaidos.<\/p>\n<p>Tai, kas i\u0161d\u0117styta pirmiau, leid\u017eia teigti, kad daugeliu atvej\u0173 vidutinio ir sunkaus svorio balansavimo stakl\u0117ms keliamas tikslumo reikalavimas gali b\u016bti apribotas iki 0,5 g*mm\/kg ar net 1,0 g*mm\/kg likutinio savitojo disbalanso lygio. Prakti\u0161kai \u012fgyvendindamas \u0161i\u0105 rekomendacij\u0105 gamintojas gali gerokai suma\u017einti ma\u0161inos gamybos sud\u0117tingum\u0105 ir s\u0105naudas, o u\u017esakovas (jei \u012fgyvendinamas racionalus technologinis procesas) gali pasiekti reikiam\u0105 balansavimo tikslum\u0105. Pagrindin\u0117 \u0161ios taisykl\u0117s i\u0161imtis gali b\u016bti nedidel\u0117s specializuotos balansavimo ma\u0161inos, naudojamos, pavyzd\u017eiui, giroskop\u0173 rotoriams balansuoti, automobili\u0173 turbokompresoriams balansuoti ir pan. \u0160i\u0173 ma\u0161in\u0173 konstrukcin\u0117s savyb\u0117s leid\u017eia pasiekti 0,1 g*mm\/kg ar ma\u017eesn\u012f liekamojo savitojo disbalanso lyg\u012f, kuris yra techni\u0161kai pagr\u012fstas ir ekonomi\u0161kai \u012fmanomas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/03\/5969837695301697400_120.webp\" alt=\"Balanset-1A liekamojo savitojo disbalanso matavimas\" width=\"706\" height=\"691\" class=\"aligncenter size-full wp-image-3611\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/03\/5969837695301697400_120.webp 706w, https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/03\/5969837695301697400_120-600x587.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/03\/5969837695301697400_120-300x294.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/03\/5969837695301697400_120-12x12.webp 12w, https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/03\/5969837695301697400_120-50x50.webp 50w\" sizes=\"auto, (max-width: 706px) 100vw, 706px\" \/><\/p>\n<h2>2. D\u0117l b\u016btinyb\u0117s \u012ftraukti balansavimo stakles \u012f Matavimo priemoni\u0173 registr\u0105<\/h2>\n<p>Pastaraisiais metais m\u016bs\u0173 \u0161alyje buvo padarytas stulbinantis atradimas, kuris gal\u0117jo sugluminti \"ramyb\u0117je i\u0161\u0117jusius\" ENIMS** specialistus, suk\u016brusius metalo pjovimo stakli\u0173 klasifikatori\u0173. Ka\u017ekieno \"lengva ranka\" ma\u0161in\u0173 rinkoje atsirado visi\u0161kai naujo tipo \u012franga - \"Vibracijos matavimo balansavimo ma\u0161inos\", kurios privalo tur\u0117ti Rusijos valstybinio standarto sertifikat\u0105 ir atitinkam\u0105 \u017eenklinim\u0105*).<\/p>\n<p>Viskas b\u016bt\u0173 buv\u0119 gerai, ta\u010diau staiga paai\u0161k\u0117jo, kad \"pa\u017eang\u016bs\" klientai \u012f savo technines specifikacijas prad\u0117jo \u012ftraukti privalom\u0105 reikalavim\u0105 \u012ftraukti balansavimo stakles \u012f Matavimo priemoni\u0173 registr\u0105. Pabandykime suprasti, kiek teisi\u0161kai ir techni\u0161kai pagr\u012fstas \u0161is reikalavimas, taip pat jo ekonomin\u012f pagr\u012fstum\u0105.<\/p>\n<p>Pirmiausia naudinga suprasti, kaip \u0161is reikalavimas susij\u0119s su galiojan\u010di\u0173 normini\u0173 dokument\u0173 rekomendacijomis. Prad\u0117kime nuo ISO 8-82 \"Metalo pjovimo stakl\u0117s. Bendrieji tikslumo bandymo reikalavimai\". \u0160iame standarte nustatytos pagrindin\u0117s stakli\u0173 klasifikavimo pagal tikslum\u0105 s\u0105vokos ir principai, bendrieji tikslumo bandymo reikalavimai ir bendrieji tikslumo tikrinimo metod\u0173 reikalavimai. Svarbu pa\u017eym\u0117ti, kad \u0161iame standarte nuorodose \u012f stakli\u0173 kokybini\u0173 charakteristik\u0173 vertinimo proced\u016bras vartojamas tik terminas \"patikra\", o apie b\u016btinyb\u0119 \u012ftraukti stakles \u012f Matavimo priemoni\u0173 registr\u0105 ir atitinkamai j\u0173 \"kalibravimo\" poreik\u012f neu\u017esimenama.<\/p>\n<p>Kitas dokumentas, \u012f kur\u012f verta atkreipti d\u0117mes\u012f, yra ISO 21940-21 (anks\u010diau ISO 2953) &#8220;Mechanical vibration \u2013 Rotor balancing \u2013 Part 21: Description and evaluation of balancing machines.&#8221; \u0160iame standarte, nustatan\u010diame konkre\u010dius balansavimo stakli\u0173 technini\u0173 charakteristik\u0173 ir j\u0173 &#8220;verifikavimo&#8221; metod\u0173 reikalavimus, taip pat n\u0117ra reikalavim\u0173, numatan\u010di\u0173 b\u016btinyb\u0119 kalibruoti stakles ir \u012ftraukti jas \u012f matavimo priemoni\u0173 registr\u0105. \u0160iuo at\u017evilgiu pa\u017eym\u0117tina, kad su kalibravimu susijusi\u0173 reikalavim\u0173 n\u0117ra ir kituose stakli\u0173 tip\u0173 standartuose, pavyzd\u017eiui, ISO standartuose \u0161lifavimo stakl\u0117ms ir CNC stakl\u0117ms, kurios taip pat gali tur\u0117ti \u012fvairias matavimo sistemas.<\/p>\n<p>Be to, pana\u0161i\u0173 reikalavim\u0173 n\u0117ra vis\u0173 \u017einom\u0173 u\u017esienio balansavimo ma\u0161in\u0173 modeli\u0173 techniniuose dokumentuose, o tai, m\u016bs\u0173 nuomone, taip pat yra svarbus precedentas. Remiantis pirmiau pateiktais argumentais, galima daryti tokias i\u0161vadas:<\/p>\n<ol>\n<li>Esamuose stakl\u0117ms, ypa\u010d balansavimo stakl\u0117ms, parengtuose norminiuose ir techniniuose dokumentuose nenumatyti reikalavimai d\u0117l j\u0173 \u012ftraukimo \u012f Matavimo priemoni\u0173 registr\u0105 ir atitinkamai j\u0173 kalibravimo poreikio. D\u0117l to toki\u0173 reikalavim\u0173 \u012ftraukimas \u012f technines specifikacijas per konkursines vie\u0161\u0173j\u0173 pirkim\u0173 proced\u016bras \"de facto\" gerokai padidina stakli\u0173 gamybos ir v\u0117lesnio j\u0173 eksploatavimo i\u0161laidas ir, kaip mums atrodo, \"de jure\" pa\u017eeid\u017eia s\u0105\u017eining\u0173 stakli\u0173 gamintoj\u0173, kurie laikosi galiojan\u010di\u0173 normini\u0173 dokument\u0173 raid\u0117s ir dvasios, teises.<\/li>\n<li>Matavimo sistemos rutininiai bandymai gali ir turi b\u016bti atliekami kaip balansavimo stakli\u0173 dalis pagal ISO 21940-21 (anks\u010diau ISO 2953) reikalavimus ir rekomendacijas, kurios numato naudojim\u0105si etaloniniu rotoriumi, bandom\u0173j\u0173 svareli\u0173 rinkiniu ir kalibruotomis svarstykl\u0117mis patikros metu. \u0160ie bandymai privalomai turi apimti \u0161i\u0173 tip\u0173 patikras:\n<ul>\n<li>Ma\u017eiausiai pasiekiamo likutinio disbalanso tikrinimas (Umar);<\/li>\n<li>Tikrinamas disbalanso ma\u017einimo koeficientas (URR);<\/li>\n<li>S\u0105lyginio balansavimo grandin\u0117s veikimo patikrinimas (atliekant rotoriaus pasukimo 180\u00b0 kampu proced\u016br\u0105).<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p>Svarbu pa\u017eym\u0117ti, kad \u0161ie patikrinimai atliekami nei\u0161montuojant matavimo sistemos i\u0161 ma\u0161inos ir nereikia naudoti kalibravimo vibracijos stendo, tod\u0117l nebereikia pasitelkti i\u0161or\u0117s organizacij\u0173 specialist\u0173 ir gerokai suma\u017e\u0117ja darbo imlumas bei darbo s\u0105naudos. Be pirmiau min\u0117t\u0173 pagrindini\u0173 patikr\u0173, prireikus tiesiogiai ant ma\u0161inos galima patikrinti ir kitus svarbius matavimo sistemos parametrus (naudojant min\u0117t\u0105 etalonin\u012f rotori\u0173, bandom\u0173j\u0173 svori\u0173 rinkin\u012f ir kalibruotas svarstykles), pvz:<\/p>\n<ul>\n<li>Vibracijos signalo amplitud\u0117s ir faz\u0117s rodmen\u0173 pasikartojamumas atliekant \u012fvairius matavimus;<\/li>\n<li>Matavimo sistemos rodmen\u0173 tiesi\u0161kumas pagal vibracijos signalo amplitud\u0119;<\/li>\n<li>matavimo sistemos skiriamoji geba (ma\u017eiausias disbalanso lygis, kur\u012f nuolat fiksuoja matavimo sistema) ir t. t.<\/li>\n<\/ul>\n<h2>I\u0161vada<\/h2>\n<p>Autorius tikisi, kad tiek balansavimo ma\u0161in\u0173 u\u017esakovai, tiek gamintojai supras \u0161iame darbe i\u0161d\u0117stytus argumentus ir rekomendacijas, kuri\u0173 pagrindinis tikslas - suma\u017einti abiej\u0173 \u0161ali\u0173 gamybos s\u0105naudas ir kartu u\u017etikrinti tinkam\u0105 balansavimo operacij\u0173 kokyb\u0119.<\/p>\n<p><em>*Pastaba:<\/em> Jei \u0161i tendencija ir toliau vystysis, neatmetama galimyb\u0117, kad netrukus su\u017einosime apie vibracijos matavimo \u0161lifavimo stakli\u0173, vibracijos matavimo pres\u0173 ir net vibracijos matavimo valcavimo stakli\u0173 k\u016brim\u0105. Juk joms su balansavimo stakl\u0117mis yra bendra galimyb\u0117 naudoti specializuot\u0105 vibracijos matavimo \u012frang\u0105.<\/p>\n<p>ENIMS rei\u0161kia \"Eksperimentinis metalo pjovimo stakli\u0173 tyrim\u0173 institutas\" (\u042d\u043a\u0441\u043f\u0435\u0440\u0438\u043c\u0435\u043d\u0442\u0430\u043b\u044c\u043d\u043e-\u0438\u0441\u0441\u043b\u0435\u0434\u043e\u0432\u0430\u0442\u0435\u043b\u044c\u0441\u043a\u0438\u0439 \u0438\u043d\u0441\u0442\u0438\u0442\u0443\u0442 \u043c\u0435\u0442\u0430\u043b\u043b\u043e\u0440\u0435\u0436\u0443\u0449\u0438\u0445 \u0441\u0442\u0430\u043d\u043a\u043e\u0432). Tai buvo Soviet\u0173 S\u0105jungos mokslini\u0173 tyrim\u0173 institutas, skirtas \u012fvairi\u0173 tip\u0173 metalo pjovimo stakl\u0117ms ir \u012frangai kurti ir tobulinti. Institutas atliko svarb\u0173 vaidmen\u012f tobulinant stakli\u0173 pramon\u0119 ir standartizuojant metalo apdirbimo \u012frang\u0105, rengdamas norminius dokumentus ir standartus, pavyzd\u017eiui, stakli\u0173 klasifikatorius ir j\u0173 tikslumo tikrinimo metodus.<\/p>\n<p>V.D. Feldmanas, UAB \"Kinematics\" vyriausiasis specialistas, 2024 m.<\/p>","protected":false},"excerpt":{"rendered":"<p>Two Remarks on the Reasonableness of Customer Requirements for Balancing Machine Manufacturers Introduction Over the past one and a half years, our company has received more than 30 inquiries regarding the purchase of various types of balancing machines. An analysis of the Technical Specifications attached to these inquiries reveals that [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":4081,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ai_generated_summary":"","footnotes":""},"categories":[54],"tags":[],"class_list":["post-4285","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-content"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/posts\/4285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/comments?post=4285"}],"version-history":[{"count":3,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/posts\/4285\/revisions"}],"predecessor-version":[{"id":102215,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/posts\/4285\/revisions\/102215"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/media\/4081"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/media?parent=4285"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/categories?post=4285"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vibromera.eu\/lt\/wp-json\/wp\/v2\/tags?post=4285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}