{"id":101581,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101581"},"modified":"2026-07-02T19:11:15","modified_gmt":"2026-07-02T19:11:15","slug":"vibration-analyzer","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/lv\/balancing-catalog\/vibration-analyzer\/","title":{"rendered":"Vibr\u0101ciju analizators un FFT spektrs - Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/lv\/balancing-catalog\/\">Balans\u0113\u0161anas pakalpojumi<\/a> &rsaquo; Vibr\u0101ciju analizators<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Vibr\u0101ciju analizators - divu kan\u0101lu FFT spektra, f\u0101zes un defektu diagnostika<\/h1>\n<p class=\"lede\">Balanset-1A ir divkan\u0101lu vibr\u0101ciju analizators, kas att\u0113lo re\u0101llaika FFT spektrus, m\u0113ra amplit\u016bdu un f\u0101zi pie 1 \u00d7 apgriezieniem min\u016bt\u0113 un kart\u0113 defektu paz\u012bmes, lai noteiktu nel\u012bdzsvarot\u012bbu, nesaska\u0146ot\u012bbu, atsl\u0101bumu un gult\u0146u boj\u0101jumus - p\u0113c tam veic balans\u0113\u0161anu vienas sesijas laik\u0101. Viens p\u0101rn\u0113s\u0101jams komplekts par 1 975 eiro nodro\u0161ina diagnostiku, korekciju un verifik\u0101ciju bez instrumentu p\u0101rsl\u0113g\u0161anas.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/lv\/balanset-1a\/\">Ieg\u0101d\u0101jieties Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/lv\/community\/\">Jaut\u0101jiet m\u016bsu in\u017eenierim<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/02\/interface-1-e1518391488191.webp\" alt=\"Balanset-1A vibr\u0101ciju analizatora FFT spektra saskarne kl\u0113pjdator\u0101\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>\u012asum\u0101:<\/b> The Balanset-1A vibr\u0101ciju analizators captures simultaneous two-channel signals from its two vibr\u0101cija sensors (analog MEMS accelerometers), computes a real-time FFT spectrum, and displays amplitude and phase at every v\u0101rpsta-order harmonic. Unbalance appears as a dominant 1&times; RPM peak; misalignment as elevated 2&times; and 3&times; components; developed gultnis defects as BPFO\/BPFI peaks and sidebands; looseness as sub-harmonics. Because the same hardware and sensors are used for balans\u0113\u0161ana uz vietas, you diagnose the fault, correct it, and verify the result in a single site visit &mdash; measuring vibr\u0101cijas \u0101trums from 0.2 to 80&nbsp;mm\/s across 5 to 1000&nbsp;Hz.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#when\">Kad analiz\u0113t<\/a><br \/>\n<a href=\"#measures\">Ko t\u0101 m\u0113ra<\/a><br \/>\n<a href=\"#faults\">K\u013c\u016bdu diagnostika<\/a><br \/>\n<a href=\"#how\">K\u0101 to lietot<\/a><br \/>\n<a href=\"#standards\">Standarti<\/a><br \/>\n<a href=\"#device\">Balanset-1A<\/a><br \/>\n<a href=\"#screenshots\">Ekr\u0101n\u0161\u0101vi\u0146i<\/a><br \/>\n<a href=\"#cases\">Re\u0101li gad\u012bjumi<\/a><br \/>\n<a href=\"#calc\">Kalkulatori<\/a><br \/>\n<a href=\"#faq\">BIE\u017d\u0100K UZDOTIE JAUT\u0100JUMI<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"when\">\n<h2>Paz\u012bmes, ka j\u016bsu ma\u0161\u012bnai ir nepiecie\u0161ama vibr\u0101cijas anal\u012bze, nevis tikai skait\u012bt\u0101ja r\u0101d\u012bjumi<\/h2>\n<p>Viens kop\u0113jais vibr\u0101ciju skaits liecina, ka kaut kas nav k\u0101rt\u012bb\u0101. FFT spektrs par\u0101da, kas un k\u0101p\u0113c. \u0160\u0101d\u0101s situ\u0101cij\u0101s ir nepiecie\u0161ams atbilsto\u0161s analizators:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Nav zin\u0101ms vibr\u0101cijas c\u0113lonis<\/b> Kop\u0113jais l\u012bmenis ir paaugstin\u0101ts, bet nevar noteikt, vai vain\u012bgs ir nel\u012bdzsvarot\u012bba, nesaska\u0146ot\u012bba, atsl\u0101bums vai gult\u0146u boj\u0101jums - FFT no\u0161\u0137ir katru parakstu.<\/div>\n<div><b>Sp\u0113c\u012bgs 1 \u00d7 RPM komponents<\/b> Domin\u0113jo\u0161ais pirm\u0101s k\u0101rtas p\u012b\u0137is ir m\u0101c\u012bbu gr\u0101matas paraugs, kas liecina par atliku\u0161o rotora nel\u012bdzsvarot\u012bbu un liek turpin\u0101t balans\u0113\u0161anu.<\/div>\n<div><b>Paaugstin\u0101tas 2\u00d7 vai 3\u00d7 harmonikas<\/b> Izteikta otr\u0101s vai tre\u0161\u0101s k\u0101rtas komponente parasti nor\u0101da uz sakabju vai v\u0101rpstu le\u0146\u0137isku vai paral\u0113lu neatbilst\u012bbu.<\/div>\n<div><b>Subharmoniskie vai platjoslas trok\u0161\u0146i<\/b> Low-order gultnis defect frequencies (BPFO, BPFI, BSF, FTF) and their harmonics appear in the velocity spectrum as a defect develops &mdash; a warning worth trending before a breakdown, though the very earliest damage stage needs high-frequency envelope analysis.<\/div>\n<div><b>Pie\u0146em\u0161anas p\u0101rbaude p\u0113c remonta<\/b> P\u0113c balans\u0113\u0161anas, regul\u0113\u0161anas vai gult\u0146u nomai\u0146as ir nepiecie\u0161ams izm\u0113r\u012bts pier\u0101d\u012bjums, ka l\u012bmenis ir samazin\u0101jies zem ISO 20816 pie\u013caujam\u0101s robe\u017eas.<\/div>\n<div><b>Periodiska st\u0101vok\u013ca monitoringa apseko\u0161ana<\/b> Regul\u0101ri re\u0123istr\u0113jot b\u0101zes l\u012bnijas spektrus, varat noteikt pieaugo\u0161o amplit\u016bdu tendences un pl\u0101not apkopi pirms nepl\u0101notas izsl\u0113g\u0161anas.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"measures\">\n<h2>Ko m\u0113ra Balanset-1A analizators<\/h2>\n<p>The analyzer captures simultaneous signals from the two supplied vibr\u0101cija sensors (analog MEMS accelerometers) referenced to the laser tachometer. Every parameter listed below is available in a single acquisition run:<\/p>\n<ul class=\"vbm-list\">\n<li>Kop\u0113jais vibr\u0101cijas \u0101trums (mm\/s RMS) un pa\u0101trin\u0101jums (m\/s\u00b2 vai g)<\/li>\n<li>Re\u0101l\u0101 laika FFT frekven\u010du spektrs ar lietot\u0101ja izv\u0113l\u0113tu iz\u0161\u0137irtsp\u0113ju<\/li>\n<li>Vibr\u0101cijas vi\u013c\u0146u forma (laika zonas sign\u0101ls) abos kan\u0101los vienlaic\u012bgi<\/li>\n<li>F\u0101zes le\u0146\u0137is pie 1 \u00d7 RPM attiec\u012bb\u0101 pret v\u0101rpstas tahometra atskaites punktu<\/li>\n<li>1\u00d7, 2\u00d7, 3\u00d7 un augst\u0101kas k\u0101rtas v\u0101rpstas amplit\u016bdas, kas ieg\u016btas no FFT<\/li>\n<li>Vienlaic\u012bga divu kan\u0101lu ieg\u016b\u0161ana (abas gult\u0146u plaknes vienlaic\u012bgi)<\/li>\n<li>Darb\u012bbas \u0101trums (RPM) no optisk\u0101 l\u0101zera tahometra - nav nepiecie\u0161ama datu pl\u0101ksn\u012bte<\/li>\n<li>Vibr\u0101cijas tenden\u010du \u017eurn\u0101ls sec\u012bgos m\u0113r\u012bjumos<\/li>\n<li>Druk\u0101jams p\u0101rskats: vi\u013c\u0146u forma, spektrs un skaitlisks kopsavilkums<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>up to &times;10<\/b><span>gultnis life when the unbalance load is halved (ISO 281)<\/span><\/div>\n<div class=\"vbm-stat\"><b>-70%<\/b><span>tipisks vibr\u0101cijas kritums p\u0113c vienas balans\u0113\u0161anas sesijas<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>kan\u0101li, vienlaic\u012bga ieg\u016b\u0161ana<\/span><\/div>\n<div class=\"vbm-stat\"><b>5&ndash;1000&nbsp;Hz<\/b><span>analizatora frekven\u010du diapazons<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"faults\">\n<h2>Boj\u0101jumu diagnostika - FFT spektra nolas\u012b\u0161ana<\/h2>\n<p>Katrs meh\u0101niskais defekts atst\u0101j at\u0161\u0137ir\u012bgu spektr\u0101lo nospiedumu. T\u0101l\u0101k dotaj\u0101 tabul\u0101 ir att\u0113loti visbie\u017e\u0101k sastopamie defekti un to spektr\u0101l\u0101s paz\u012bmes, lai j\u016bs var\u0113tu nolas\u012bt ma\u0161\u012bnas st\u0101vokli tie\u0161i no Balanset-1A displeja.<\/p>\n<table class=\"vbm-table\">\n<caption>Vibr\u0101cijas defektu diagnostikas rokasgr\u0101mata - spektr\u0101l\u0101s paz\u012bmes<\/caption>\n<thead>\n<tr>\n<th>K\u013c\u016bme<\/th>\n<th>Domin\u0113jo\u0161ie spektr\u0101lie komponenti<\/th>\n<th>Citi r\u0101d\u012bt\u0101ji<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Rotora disbalanss<\/b><\/td>\n<td>Sp\u0113c\u012bgs 1 \u00d7 RPM; visi p\u0101r\u0113jie pas\u016bt\u012bjumi zems<\/td>\n<td>F\u0101ze stabila; amplit\u016bda pieaug l\u012bdz ar \u0101truma kvadr\u0101tu; apstiprin\u0101ts ar izm\u0113\u0123in\u0101juma svara testu.<\/td>\n<\/tr>\n<tr>\n<td><b>Le\u0146\u0137isk\u0101 nob\u012bde<\/b><\/td>\n<td>Paaugstin\u0101ts 1 \u00d7 un 2 \u00d7; da\u017ereiz 3 \u00d7<\/td>\n<td>Aksi\u0101l\u0101 vibr\u0101cija bie\u017ei vien\u0101da ar radi\u0101lo vai liel\u0101ka par to; f\u0101\u017eu starp\u012bba p\u0101ri sakabei \u2248180\u00b0.<\/td>\n<\/tr>\n<tr>\n<td><b>Paral\u0113l\u0101 asu nesakrit\u012bba<\/b><\/td>\n<td>Sp\u0113c\u012bgs 2 \u00d7 RPM; var b\u016bt ar\u012b 1 \u00d7 RPM<\/td>\n<td>Augsta radi\u0101l\u0101 vibr\u0101cija; 180\u00b0 f\u0101zes nob\u012bde, kas izm\u0113r\u012bta p\u0101ri sakabei radi\u0101l\u0101 virzien\u0101.<\/td>\n<\/tr>\n<tr>\n<td><b>Meh\u0101niskais va\u013c\u012bgums<\/b><\/td>\n<td>Subharmonisk\u0101s (0,5\u00d7, 0,33\u00d7) un vair\u0101kas harmonisk\u0101s l\u012bdz 10\u00d7.<\/td>\n<td>Paaugstin\u0101ts platjoslas trok\u0161\u0146u l\u012bmenis; simptomi pasliktin\u0101s, ja ir slodze<\/td>\n<\/tr>\n<tr>\n<td><b>Rito\u0161o elementu gult\u0146u nodilums<\/b><\/td>\n<td>BPFO, BPFI, BSF vai FTF defektu frekvences un to harmonikas<\/td>\n<td>Var par\u0101d\u012bties pirms kop\u0113j\u0101 l\u012bme\u0146a paaugstin\u0101\u0161an\u0101s; blakusjoslas ap defektu frekvenc\u0113m apstiprina progres\u0113\u0161anu.<\/td>\n<\/tr>\n<tr>\n<td><b>Rezonanse<\/b><\/td>\n<td>Liela amplit\u016bda tuvu dabiskajai frekvencei, kas bie\u017ei vien nav sinhrona ar apgriezienu skaitu.<\/td>\n<td>Amplit\u016bdas maksimums pie noteikta \u0101truma; f\u0101ze l\u012bdz rezonansei p\u0101rvietojas par ~ 180\u00b0.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kad 1 \u00d7 komponente domin\u0113, p\u0101rsl\u0113dziet tie\u0161i uz balans\u0113\u0161anas re\u017e\u012bmu - Balanset-1A izmanto to pa\u0161u m\u0113r\u012bjumu k\u0101 b\u0101zes l\u012bniju ietekmes koeficienta apr\u0113\u0137inam, t\u0101p\u0113c laiks netiek zaud\u0113ts.<\/p>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>K\u0101p\u0113c viens kop\u0113jais skaitlis ir k\u013c\u016bdains<\/h2>\n<p>Vibr\u0101cijas pildspalva vai vienk\u0101r\u0161s RMS m\u0113r\u012bt\u0101js apkopo visas frekvences komponentes vien\u0101 skaitl\u012b. Divas ma\u0161\u012bnas var uzr\u0101d\u012bt identiskus kop\u0113jos l\u012bme\u0146us, bet t\u0101m var b\u016bt piln\u012bgi at\u0161\u0137ir\u012bgi defekti - vien\u0101 domin\u0113 1\u00d7 disbalanss, bet otr\u0101 - gult\u0146u defektu blakusjoslas. Bez frekven\u010du iz\u0161\u0137irtsp\u0113jas j\u016bs tikai nojau\u0161at c\u0113loni un risk\u0113jat piem\u0113rot nepareizu l\u012bdzekli. FFT dekompon\u0113 sign\u0101lu t\u0101, ka katrs defekta tips par\u0101d\u0101s k\u0101 mar\u0137\u0113ts maksimums ar savu rakstur\u012bgo frekvenci, t\u0101d\u0113j\u0101di vien\u0101 m\u0113r\u012bjum\u0101 tiek noteikta gan diagnoze, gan recepte.<\/p>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> shows why the diagnosis matters financially. Rolling-gultnis basic rating life is <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b> (in millions of revolutions), where P is the equivalent dynamic gultnis load and p = 3 for ball gultniss (10\/3 for roller gultniss). Residual unbalance adds a rotating component to that load, so halving the 1&times; vibr\u0101cija amplitude roughly halves the unbalance load; where this rotating load dominates P, gultnis life multiplies by up to 2<sup>p<\/sup>: par <b>8\u00d7 lod\u012b\u0161u gult\u0146iem un ~10\u00d7 rull\u012b\u0161u gult\u0146iem.<\/b>. The estimate holds only when the measured 1&times; vibr\u0101cija is a reasonable proxy for the rotating dynamic gultnis load. Use the <a href=\"https:\/\/vibromera.eu\/lv\/calculators\/bearing-load\/\">gult\u0146u kalku\u013ckalku\u013cot\u0101js<\/a> lai apr\u0113\u0137in\u0101tu, cik daudz l\u012bdzek\u013cu ietaup\u012bs j\u016bsu ma\u0161\u012bna.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>K\u0101 izmantot Balanset-1A k\u0101 vibr\u0101ciju analizatoru - soli pa solim<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Uzst\u0101diet sensorus.<\/b> Attach one or both vibr\u0101cija sensors to the gultnis housings using the magnetic mounts. For phase-referenced analysis, clip the laser tachometer reflective strip to the rotating v\u0101rpsta and aim the sensor at it (50&ndash;500&nbsp;mm working range). Both channels record simultaneously.<\/li>\n<li><b>Palaidiet rotoru un ieg\u016bstiet.<\/b> Atveriet Balanset programmat\u016bru, atlasiet <em>Analizators<\/em> re\u017e\u012bmu un s\u0101ciet datu ieg\u016b\u0161anu. Programmat\u016bra r\u0101da vi\u013c\u0146u formu, FFT spektru un kop\u0113jo vid\u0113jo kvadr\u0101tisko kvadr\u0101tisko vibr\u0101cijas l\u012bmeni mm\/s re\u0101laj\u0101 laik\u0101 standarta Windows kl\u0113pjdator\u0101.<\/li>\n<li><b>Las\u012bt spektru.<\/b> Identific\u0113jiet domin\u0113jo\u0161\u0101s frekvences maksimumus. Pirm\u0101s k\u0101rtas amplit\u016bda un f\u0101ze tiek autom\u0101tiski par\u0101d\u012bta pret taho impulsu. Skatiet iepriek\u0161 min\u0113to defektu tabulu, lai saska\u0146otu spektr\u0101lo modeli ar visticam\u0101ko defekta tipu.<\/li>\n<li><b>Sal\u012bdziniet ar pie\u0146em\u0161anas robe\u017e\u0101m.<\/b> P\u0101rbaudiet kop\u0113j\u0101 \u0101truma r\u0101d\u012bjumu atbilst\u012bbu attiec\u012bgajam <b>ISO 20816<\/b> zonas robe\u017ea (A\/B\/C\/D) j\u016bsu ma\u0161\u012bnas klasei un jaudai. Eksport\u0113jiet spektra diagrammu un skaitlisk\u0101s v\u0113rt\u012bbas tehnisk\u0101s apkopes p\u0101rskatam.<\/li>\n<li><b>Ja nel\u012bdzsvarot\u012bba ir apstiprin\u0101ta, taj\u0101 pa\u0161\u0101 sesij\u0101 veiciet l\u012bdzsvaro\u0161anu.<\/b> Jau veiktais b\u0101zes l\u012bnijas m\u0113r\u012bjums kalpo k\u0101 pirmais ietekmes koeficienta sec\u012bbas posms. Pievienojiet izm\u0113\u0123in\u0101juma svaru, veiciet v\u0113lreiz un \u013caujiet programmat\u016brai apr\u0113\u0137in\u0101t korekciju - bez papildu instrumentiem, bez atk\u0101rtota apmekl\u0113juma.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Vibr\u0101cijas m\u0113r\u012bjumu standarti<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 20816<\/b> defin\u0113 vibr\u0101cijas \u0101truma (mm\/s vid\u0113j\u0101 \u0123eometrisk\u0101 v\u0113rt\u012bba) nov\u0113rt\u0113juma zonas nerot\u0113jo\u0161\u0101m deta\u013c\u0101m: A zona (tikko nodota ekspluat\u0101cij\u0101), B zona (pie\u0146emama ilgsto\u0161ai ekspluat\u0101cijai), C zona (trauksme - t\u016bl\u012bt\u0113ja izmekl\u0113\u0161ana), D zona (b\u012bstam\u012bba - boj\u0101jumu risks). Robe\u017eas at\u0161\u0137iras atkar\u012bb\u0101 no ma\u0161\u012bnas klases un v\u0101rpstas centra augstuma. Balanset-1A zi\u0146o kop\u0113jo \u0101trumu mm\/s RMS, lai j\u016bs var\u0113tu tie\u0161i sal\u012bdzin\u0101t ar attiec\u012bgo ISO 20816 da\u013cu j\u016bsu ma\u0161\u012bnas tipam.<\/p>\n<p>Kad nel\u012bdzsvarot\u012bba ir identific\u0113ta, atlikus\u012b nel\u012bdzsvarot\u012bba p\u0113c balans\u0113\u0161anas tiek nov\u0113rt\u0113ta, sal\u012bdzinot ar <b>ISO 21940-11<\/b> G klases (no G0,4 l\u012bdz G40). Balanset-1A dokument\u0113 ieg\u016bto atliku\u0161o nel\u012bdzsvarot\u012bbu izdruk\u0101jam\u0101 p\u0101rskat\u0101, t\u0101d\u0113j\u0101di sniedzot jums p\u0101rbaud\u0101mu p\u0101rskatu par atbilst\u012bbu piem\u0113rojamajam standartam. Izmantojiet <a href=\"https:\/\/vibromera.eu\/lv\/calculators\/residual-unbalance-iso1940\/\">atlikuma un nel\u012bdzsvarot\u012bbas kalkulators<\/a> lai noskaidrotu pie\u013caujamo pielaidi, pirms s\u0101kat darbu.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A - j\u016bsu piln\u012bgs lauka analizatora un balans\u0113\u0161anas komplekts<\/h2>\n<p>Viss \u0161aj\u0101 lap\u0101 aprakst\u012btais tiek dar\u012bts ar vienu portat\u012bvo instrumentu: <a href=\"https:\/\/vibromera.eu\/lv\/balanset-1a\/\">Balanset-1A<\/a>. Tas ir divkan\u0101lu dinamiskais balans\u0113t\u0101js un vibr\u0101ciju analizators, kas diagnostic\u0113 defektus no FFT spektra un, ja tiek apstiprin\u0101ts nel\u012bdzsvarot\u012bbas tr\u016bkums, balans\u0113 cietos rotorus. <strong>savos gult\u0146os, ar darba \u0101trumu<\/strong>, izmantojot 3 ietekmes koeficientu metodi - programmat\u016bra apr\u0113\u0137ina prec\u012bzu korekcijas masu un le\u0146\u0137i un saglab\u0101 zi\u0146ojumu.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Pilns Balanset-1A balans\u0113\u0161anas komplekts ar sensoriem, l\u0101zera tahometru, skalu un korpusu\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Pilna komplekta saturs<\/h3>\n<p class=\"price\">1975\u00a0eiro <span>- Pilns komplekts, noliktav\u0101, PVN r\u0113\u0137ins<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Interfeisa m\u0113rvien\u012bba (USB, 2 kan\u0101li)<\/li>\n<li>Divi vibr\u0101cijas akselerometri (4 m kabelis, 10 m p\u0113c izv\u0113les)<\/li>\n<li>L\u0101zera tahometrs \/ optiskais f\u0101zes sensors (50-500 mm)<\/li>\n<li>Sensora magn\u0113tiskais stat\u012bvs<\/li>\n<li>Digit\u0101lie svari izm\u0113\u0123in\u0101juma un korekcijas svariem<\/li>\n<li>Windows balans\u0113\u0161anas un anal\u012bzes programmat\u016bra<\/li>\n<li>Plastmasas transport\u0113\u0161anas korpuss<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/lv\/balanset-1a\/\">Apskat\u012bt Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/lv\/community\/\">Jaut\u0101jiet m\u016bsu in\u017eenierim<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Ieteicamais<\/span><\/p>\n<h3>Pilns komplekts<\/h3>\n<p>Vien\u012bba - 2 sensori - l\u0101zera tahometrs - magn\u0113tiskais stat\u012bvs - digit\u0101l\u0101 skala - programmat\u016bra - transport\u0113\u0161anas koferis. Viss, kas nepiecie\u0161ams, lai s\u0101ktu analiz\u0113t un balans\u0113t p\u0113c iz\u0146em\u0161anas no iepakojuma.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>OEM komplekts<\/h3>\n<p>Vien\u012bba - 2 sensori - l\u0101zera tahometrs - programmat\u016bra. Integratoriem, kuriem jau ir stat\u012bvs, svari un korpuss vai kuri ieb\u016bv\u0113 ier\u012bci balans\u0113\u0161anas iek\u0101rt\u0101.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Galven\u0101s tehnisk\u0101s specifik\u0101cijas<\/caption>\n<thead>\n<tr>\n<th>Parametrs<\/th>\n<th>V\u0113rt\u012bba<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M\u0113r\u012b\u0161anas kan\u0101li<\/td>\n<td>2 (vienas un divu plak\u0146u balans\u0113\u0161ana)<\/td>\n<\/tr>\n<tr>\n<td>Vibr\u0101cijas \u0101truma diapazons<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Frekven\u010du diapazons<\/td>\n<td>5&ndash;1000 Hz (&le;10% amplit\u016bdas k\u013c\u016bda virs 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>M\u0113r\u012bjumu precizit\u0101te<\/td>\n<td>\u00b15% no pilnas skalas<\/td>\n<\/tr>\n<tr>\n<td>Metode<\/td>\n<td>3 ietekmes koeficients (1 vai 2 plaknes)<\/td>\n<\/tr>\n<tr>\n<td>Anal\u012bze<\/td>\n<td>Amplit\u016bda un f\u0101ze pie 1 \u00d7, FFT spektrs un vi\u013c\u0146u forma, saglab\u0101ti zi\u0146ojumi<\/td>\n<\/tr>\n<tr>\n<td>Kl\u0113pjdators<\/td>\n<td>Nav iek\u013cauts (Windows PC, pieejams p\u0113c piepras\u012bjuma)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>\u2713<\/b> Ir noliktav\u0101<\/span><span><b>\u2713<\/b> DHL Portug\u0101le 35 \u20ac<\/span><span><b>\u2713<\/b> DHL vis\u0101 pasaul\u0113 110 \u20ac<\/span><span><b>\u2713<\/b> 2 gadu garantija<\/span><span><b>\u2713<\/b> PVN r\u0113\u0137ins<\/span><span><b>\u2713<\/b> In\u017eenieru atbalsts<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"screenshots\">\n<h2>Balanset-1A analizatora r\u0101d\u012bjumi<\/h2>\n<div class=\"vbm-cases\">\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/ChatGPT-Image-25-%D0%B8%D1%8E%D0%BB.-2025-%D0%B3.-22_07_35.webp\" alt=\"Divkan\u0101lu vibr\u0101ciju analizatora Balanset-1A p\u0101rskata ekr\u0101ns\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Divu kan\u0101lu analizatora p\u0101rskats<\/h3>\n<p>Kop\u0113jais vibr\u0101ciju l\u012bmenis, FFT spektrs un f\u0101zes le\u0146\u0137is no diviem sensoriem, kas vienlaikus tiek r\u0101d\u012bti vien\u0101 Windows kl\u0113pjdator\u0101.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/09\/Screenshot-2025-07-29-165701-scaled.webp\" alt=\"Re\u0101l\u0101 laika FFT spektrs, kur\u0101 redzami frekven\u010du maksimumi defektu diagnostikai\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Re\u0101l\u0101 laika FFT spektrs<\/h3>\n<p>Frekven\u010du maksimumi \u013cauj at\u0161\u0137irt nel\u012bdzsvarot\u012bbu (domin\u0113jo\u0161ais 1\u00d7) no nesaska\u0146ot\u012bbas (2\u00d7) un gult\u0146u defektu blakusjosl\u0101m.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/%D0%98%D0%B7%D0%BE%D0%B1%D1%80%D0%B0%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-WhatsApp-2025-10-03-%D0%B2-11.16.33_1bc14f9b.webp\" alt=\"Uz gult\u0146a korpusa uzst\u0101d\u012bts akselerometrs un l\u0101zera tahometrs uz lauka\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>M\u0113r\u012bjumi uz lauka<\/h3>\n<p>Vibration sensor and laser tachometer mounted on a running machine&rsquo;s gultnis housing &mdash; no machine disassembly required.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10461221.webp\" alt=\"Amplit\u016bda un f\u0101ze pie 1x RPM, kas par\u0101d\u012bta Balanset programmat\u016br\u0101\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Amplit\u016bda un f\u0101ze pie 1 \u00d7<\/h3>\n<p>Pirm\u0101s k\u0101rtas amplit\u016bda un f\u0101zes le\u0146\u0137is, kas par\u0101d\u012bts pret tahometra atskaites v\u0113rt\u012bbu - ievaddati, kas nepiecie\u0161ami ietekmes koeficienta balans\u0113\u0161anai.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10418068.webp\" alt=\"Druk\u0101jams Balanset-1A m\u0113r\u012bjumu p\u0101rskats ar vi\u013c\u0146u formu un spektru\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Dokument\u0113ts zi\u0146ojums<\/h3>\n<p>Vi\u013c\u0146u forma, FFT spektrs un skaitliskais kopsavilkums tiek eksport\u0113ts k\u0101 izdruk\u0101jams zi\u0146ojums tehnisk\u0101s apkopes ierakstam.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Re\u0101lu m\u0113r\u012bjumu un analizatoru gad\u012bjumi<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/lv\/piemers\/relativas-rotora-vibracijas-merisana-izmantojot-bezkontakta-linearos-parvietojuma-sensorus\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/image014.webp\" alt=\"Bezkontakta vibr\u0101ciju m\u0113r\u012b\u0161ana ar line\u0101riem p\u0101rvietojuma sensoriem\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Bezkontakta vibr\u0101ciju m\u0113r\u012b\u0161ana<\/h3>\n<p>Line\u0101ro p\u0101rvietojuma sensoru izmanto\u0161ana relat\u012bv\u0101s rotora vibr\u0101cijas m\u0113r\u012b\u0161anai bez kontakta ar v\u0101rpstu - piem\u0113roti rotoriem, kur akselerometra uzst\u0101d\u012b\u0161ana nav praktiska.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/lv\/piemers\/portable-balancer-vibration-analyzer-and-balancer-machine-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/photo_2023-04-08_17-03-49-1024x576.webp\" alt=\"Balanset-1A, ko izmanto gan k\u0101 vibr\u0101ciju analizatoru, gan k\u0101 divu plak\u0146u balans\u0113t\u0101ju\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Analizatora un balansiera apvienojums<\/h3>\n<p>Praktisks demonstr\u0113jums par to, k\u0101 ar vienu ier\u012bci var veikt vibr\u0101cijas anal\u012bzi un divu plak\u0146u balans\u0113\u0161anu vien\u0101 uzdevum\u0101, s\u0101kot no diagnostikas l\u012bdz p\u0101rbaud\u012btai korekcijai.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/lv\/piemers\/why-balancing-doesnt-reduce-vibration-troubleshooting-guide-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/06\/ChatGPT-Image-19-%D0%B8%D1%8E%D0%BD.-2025-%D0%B3.-18_31_25.webp\" alt=\"K\u0101p\u0113c balans\u0113\u0161ana nesamazina vibr\u0101ciju, izmantojot analizatoru, diagnostic\u0113\u0161ana\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Diagnostic\u0113jiet pirms l\u012bdzsvaro\u0161anas<\/h3>\n<p>Probl\u0113mu nov\u0113r\u0161anas ce\u013cvedis gad\u012bjumiem, kad tikai balans\u0113\u0161ana nesamazina vibr\u0101ciju, un k\u0101 FFT spektrs atkl\u0101j faktisko galveno c\u0113loni.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Bezmaksas vibr\u0101cijas kalkulatori<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/lv\/calculators\/bearing-load\/\">Gult\u0146u darbm\u016b\u017ea kalkulators<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lv\/calculators\/centrifugal-force-unbalance\/\">Centrb\u0113dzes sp\u0113ks no nel\u012bdzsvarot\u012bbas<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lv\/calculators\/residual-unbalance-iso1940\/\">Atliku\u0161ais disbalanss (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lv\/calculators\/trial-weight-calculator\/\">Izm\u0113\u0123in\u0101juma svara kalkulators<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>Bie\u017ei uzdotie jaut\u0101jumi par vibr\u0101ciju analizatoru<\/h2>\n<details>\n<summary>K\u0101 FFT anal\u012bze \u013cauj at\u0161\u0137irt nel\u012bdzsvarot\u012bbu no nesaska\u0146ot\u012bbas?<\/summary>\n<div class=\"ans\">Neizl\u012bdzsvarot\u012bba rada vienu domin\u0113jo\u0161u p\u012b\u0137i, kas ir prec\u012bzi 1 \u00d7 liel\u0101ks par skrie\u0161anas \u0101trumu. Le\u0146\u0137isk\u0101 nesaska\u0146ot\u012bba parasti uzr\u0101da sp\u0113c\u012bgu 2 \u00d7 un da\u017ereiz 3 \u00d7 komponenti, bie\u017ei vien ar paaugstin\u0101tu aksi\u0101lo vibr\u0101ciju. Paral\u0113l\u0101 neatbilst\u012bba rada izteiktu 2 \u00d7 radi\u0101lo maksimumu. Balanset-1A autom\u0101tiski mar\u0137\u0113 \u0161os p\u012b\u0137us FFT displej\u0101, lai j\u016bs var\u0113tu identific\u0113t domin\u0113jo\u0161o k\u013c\u016bdu, pirms lemt par korekciju. Ja domin\u0113 1\u00d7 komponente, tas pats m\u0113r\u012bjumu cikls tiek p\u0101rnests tie\u0161i uz balans\u0113\u0161anas apr\u0113\u0137inu.<\/div>\n<\/details>\n<details>\n<summary>Vai Balanset-1A var izmantot k\u0101 atsevi\u0161\u0137u analizatoru bez balans\u0113\u0161anas?<\/summary>\n<div class=\"ans\">J\u0101. Ier\u012bce darbojas tikai analizatora re\u017e\u012bm\u0101, lai re\u0123istr\u0113tu vibr\u0101cijas spektrus, m\u0113r\u012btu kop\u0113jo l\u012bmeni mm\/s un re\u0123istr\u0113tu datus st\u0101vok\u013ca uzraudz\u012bbas tendenc\u0113m - bez balans\u0113\u0161anas re\u017e\u012bma. Tas ir noder\u012bgi ien\u0101ko\u0161aj\u0101m p\u0101rbaud\u0113m, periodisk\u0101m st\u0101vok\u013ca p\u0101rbaud\u0113m un p\u0113cremonta pie\u0146em\u0161anas m\u0113r\u012bjumiem atbilsto\u0161i ISO 20816 robe\u017ev\u0113rt\u012bb\u0101m.<\/div>\n<\/details>\n<details>\n<summary>K\u0101du frekven\u010du diapazonu aptver FFT, un vai tas ir pietiekams gult\u0146u diagnostikai?<\/summary>\n<div class=\"ans\">The Balanset-1A covers 5 to 1000&nbsp;Hz, which captures all v\u0101rpsta-order harmonics plus the fundamental gultnis defect frequencies (BPFO, BPFI, BSF, FTF) and their lower harmonics for most industrial rolling-element gultniss at typical speeds. Be aware of the limit, however: early-stage gultnis damage is normally detected with high-frequency acceleration and envelope (demodulation) techniques that require bandwidth of several kHz to tens of kHz &mdash; beyond this instrument&rsquo;s range. Within 5&ndash;1000&nbsp;Hz the Balanset-1A shows gultnis faults once they produce measurable velocity components at the defect frequencies, i.e. at a more developed stage; it is not a substitute for a dedicated wideband gultnis-diagnostics instrument.<\/div>\n<\/details>\n<details>\n<summary>Vai ISO 20816 attiecas uz manu ma\u0161\u012bnu?<\/summary>\n<div class=\"ans\">ISO 20816 attiecas uz pla\u0161u rot\u0113jo\u0161o ma\u0161\u012bnu kl\u0101stu, aptverot vair\u0101kas to da\u013cas: s\u016bk\u0146i, kompresori, ventilatori, turb\u012bnas, motori un \u0123eneratori. Konkr\u0113t\u0101 zonas robe\u017ea ir atkar\u012bga no ma\u0161\u012bnas jaudas klases un v\u0101rpstas centra augstuma. Balanset-1A zi\u0146o kop\u0113jo \u0101trumu mm\/s vid\u0113j\u0101 \u0123eometrisk\u0101 v\u0113rt\u012bba, t\u0101p\u0113c j\u016bs varat piem\u0113rot to ISO 20816 da\u013cu, kas attiecas uz j\u016bsu ma\u0161\u012bnas tipu, tie\u0161i uz r\u0101d\u012bjumu.<\/div>\n<\/details>\n<details>\n<summary>Vai f\u0101zes m\u0113r\u012bjums ir pietiekami prec\u012bzs, lai veiktu l\u012bdzsvaro\u0161anu div\u0101s plakn\u0113s?<\/summary>\n<div class=\"ans\">J\u0101. F\u0101ze tiek m\u0113r\u012bta attiec\u012bb\u0101 pret optisk\u0101 tahometra impulsu, nodro\u0161inot atk\u0101rtojamu le\u0146\u0137a atskaites punktu. Divu kan\u0101lu vienlaic\u012bga ieg\u016b\u0161ana nodro\u0161ina, ka abas gult\u0146u plaknes tiek \u0146emtas vien\u0101 un taj\u0101 pa\u0161\u0101 v\u0101rpstas poz\u012bcij\u0101, kas ir \u013coti svar\u012bgi, lai veiktu prec\u012bzus krustenisk\u0101 efekta (ietekmes koeficienta) apr\u0113\u0137inus divu plak\u0146u dinamisk\u0101s balans\u0113\u0161anas darbos.<\/div>\n<\/details>\n<details>\n<summary>K\u0101 analizators var pal\u012bdz\u0113t, ja vibr\u0101cijas nenov\u0113r\u0161 tikai balans\u0113\u0161ana?<\/summary>\n<div class=\"ans\">Ja balans\u0113\u0161ana samazina 1 \u00d7 komponenti, bet kop\u0113j\u0101 vibr\u0101cija joproj\u0101m ir augsta, FFT nekav\u0113joties par\u0101da, kura cita frekvences komponente ir k\u013cuvusi domin\u0113jo\u0161a - vai t\u0101 ir 2 \u00d7 disbalans\u0113\u0161anas harmonika, gult\u0146a defekta frekvence vai subharmonisk\u0101 va\u013c\u012bguma signat\u016bra. Tas \u013cauj prec\u012bzi virz\u012bt n\u0101kamo kori\u0123\u0113jo\u0161o soli, nevis likt tehni\u0137im spriest. Praktiskus piem\u0113rus skatiet m\u016bsu gad\u012bjuma izp\u0113t\u0113 par notur\u012bgas vibr\u0101cijas diagnostic\u0113\u0161anu.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Uzziniet teoriju<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/lv\/glossary\/lauka-lidzsvarosana\/\">Lauka l\u012bdzsvaro\u0161ana<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lv\/glossary\/residual-unbalance\/\">Atliku\u0161ais disbalanss<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lv\/glossary\/balance-quality\/\">L\u012bdzsvarotas kvalit\u0101tes pak\u0101pes<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/lv\/glossary\/dynamic-balancing\/\">Dinamisk\u0101 balans\u0113\u0161ana<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Vispirms diagnostic\u0113jiet - p\u0113c tam dro\u0161i l\u012bdzsvarojiet<\/h2>\n<p>Balanset-1A nodro\u0161ina divu kan\u0101lu FFT analizatoru un divu plak\u0146u balans\u0113t\u0101ju vien\u0101 portat\u012bv\u0101 komplekt\u0101. Nolasiet defektu no spektra, kori\u0123\u0113jiet to avot\u0101 un p\u0101rbaudiet saska\u0146\u0101 ar ISO 20816 - tas viss vien\u0101 apmekl\u0113jum\u0101 uz vietas par 1 975 eiro.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/lv\/balanset-1a\/\">Apskat\u012bt Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/lv\/community\/\">Uzdot jaut\u0101jumu forum\u0101<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Vibration Analyzer Vibration Analyzer &mdash; Two-Channel FFT Spectrum, Phase &amp; Fault Diagnostics The Balanset-1A is a two-channel vibration analyzer that plots real-time FFT spectra, measures amplitude and phase at 1&times; RPM, and maps fault signatures to distinguish unbalance, misalignment, looseness and bearing damage &mdash; then balances in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101581","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/pages\/101581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/comments?post=101581"}],"version-history":[{"count":6,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/pages\/101581\/revisions"}],"predecessor-version":[{"id":102102,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/pages\/101581\/revisions\/102102"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/media?parent=101581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}