{"id":2234,"date":"2023-04-09T14:58:59","date_gmt":"2023-04-09T14:58:59","guid":{"rendered":"https:\/\/vibromera.eu\/?p=2234"},"modified":"2026-05-24T01:08:42","modified_gmt":"2026-05-24T01:08:42","slug":"portativais-vibrometrs-balansieris-lidzsvars","status":"publish","type":"post","link":"https:\/\/vibromera.eu\/lv\/example\/portable-vibrometer-balancer-arbalance\/","title":{"rendered":"Portat\u012bvais vibrometriskais balansieris ArBalance."},"content":{"rendered":"<h1>P\u0101rn\u0113s\u0101jams vibrometrs-balans\u0113t\u0101js ArBalance<\/h1>\n<p>Veicot Fecon me\u017esaimniec\u012bbas mul\u010d\u0113t\u0101ja ar FAE uzst\u0101d\u012bjumu balans\u0113\u0161anu, m\u016bsu speci\u0101lists uz\u0146\u0113ma \u012bsus video, kuros redzams, k\u0101 <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/rotors-2\/\">rotors<\/a> <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/lidzsvarosana\/\">balans\u0113\u0161ana<\/a> process.<\/p>\n<h2>ArBalance un Balanset-1A: kop\u012bga platforma<\/h2>\n<p>\u0160aj\u0101 demonstr\u0101cij\u0101 p\u0101rn\u0113s\u0101jams <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/vibration-analyzer\/\">vibr\u0101cijas analizators<\/a> Tika izmantots ArBalance. Proced\u016bra darbojas p\u0113c t\u0101 pa\u0161a principa k\u0101 l\u012bdzsvaro\u0161ana ar <a href=\"https:\/\/vibromera.eu\/lv\/produkts\/balansesanas-komplekts-1\/\">Balanset-1A<\/a> ier\u012bce. Abas sist\u0113mas izmanto identiskus vibr\u0101cijas sensorus un <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/laser-tachometer\/\">l\u0101zera tahometrs<\/a>, un to tehniskie parametri ir gandr\u012bz identiski. Vajadz\u012bbas gad\u012bjum\u0101 ArBalance var darboties ar\u012b k\u0101 atsevi\u0161\u0137a ier\u012bce <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/vibration-monitoring\/\">vibr\u0101cijas m\u0113r\u012b\u0161ana<\/a> sist\u0113ma r\u016bpnieciskaj\u0101m ma\u0161\u012bn\u0101m.<\/p>\n<p><iframe loading=\"lazy\" title=\"Mul\u010d\u0113t\u0101ja balans\u0113\u0161anas process ar ArBalance vai Balanset-1A\" width=\"563\" height=\"1000\" src=\"https:\/\/www.youtube.com\/embed\/eoeCEnBO4fs?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/vibromera.eu\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>Piln\u012bb\u0101 autonoms lauka m\u0113rinstruments<\/h2>\n<p>At\u0161\u0137ir\u012bb\u0101 no sist\u0113m\u0101m, kas piesl\u0113gtas datoram, ArBalance ir piln\u012bb\u0101 autonoms. Tam nav nepiecie\u0161ams ne portat\u012bvais dators, ne \u0101r\u0113js baro\u0161anas avots. Ieb\u016bv\u0113tais akumulators nodro\u0161ina nep\u0101rtrauktu darb\u012bbu aptuveni 10\u201312 stundas, kas padara to \u0113rtu lieto\u0161anai <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/lauka-lidzsvarosana\/\">lauka balans\u0113\u0161ana<\/a> un vibr\u0101ciju m\u0113r\u012b\u0161ana att\u0101l\u0101s teritorij\u0101s.<\/p>\n<h2>Diagnostikas iesp\u0113jas<\/h2>\n<p>Ier\u012bce par\u0101da vibr\u0101cijas grafikus, <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/time-waveform\/\">laika dom\u0113na vi\u013c\u0146u formas<\/a>, un pilns <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/spectral-analysis\/\">spektr\u0101l\u0101 anal\u012bze<\/a>. \u0160\u012bs funkcijas pal\u012bdz nov\u0113rt\u0113t iek\u0101rtas tehnisko st\u0101vokli, atkl\u0101t <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/unbalance\/\">nel\u012bdzsvarot\u012bba<\/a>, <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/misalignment\/\">v\u0101rpstu nesakrit\u012bba<\/a>vai <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/resonance\/\">rezonanse<\/a>, k\u0101 ar\u012b noteikt defektu galvenos c\u0113lo\u0146us.<\/p>\n<p>ArBalance ietver divus neatkar\u012bgus vibr\u0101cijas kan\u0101lus, kas \u013cauj veikt vibr\u0101cijas m\u0113r\u012bjumus <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/two-plane-balancing\/\">div\u0101s plakn\u0113s<\/a> uzreiz. Tas uzlabo precizit\u0101ti un efektivit\u0101ti <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/dynamic-balancing\/\">dinamisk\u0101 rotora balans\u0113\u0161ana<\/a> sal\u012bdzin\u0101jum\u0101 ar vienkan\u0101lu sist\u0113m\u0101m.<\/p>\n<p>Ieb\u016bv\u0113tais sign\u0101lu apstr\u0101des algoritms nodro\u0161ina stabilus vibr\u0101cijas r\u0101d\u012bjumus <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/amplitude\/\">amplit\u016bda<\/a> un <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/phase\/\">f\u0101ze<\/a>, pat ja ir fona vibr\u0101cijas vai elektriskie trauc\u0113jumi.<\/p>\n<p>T\u0101d\u0113j\u0101di ArBalance vibr\u0101ciju analizators ir uzticams un daudzpus\u012bgs instruments balans\u0113\u0161anai uz vietas, <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/vibration-analysis\/\">vibr\u0101cijas anal\u012bze<\/a>, k\u0101 ar\u012b rot\u0113jo\u0161o iek\u0101rtu spektr\u0101l\u0101 diagnostika.<\/p>\n<h2>Galven\u0101s iez\u012bmes<\/h2>\n<ul>\n<li>Divkan\u0101lu vibr\u0101ciju m\u0113r\u012b\u0161ana<\/li>\n<li>Vibr\u0101cija <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/velocity\/\">\u0101trums<\/a> m\u0113r\u012bjumu diapazons l\u012bdz 80 mm\/s <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/rms\/\">RMS<\/a><\/li>\n<li><a href=\"https:\/\/vibromera.eu\/lv\/glossary\/frequency\/\">Bie\u017eums<\/a> diapazons 5-1000 Hz<\/li>\n<li><a href=\"https:\/\/vibromera.eu\/lv\/glossary\/fft\/\">FFT<\/a> spektr\u0101l\u0101 anal\u012bze un sv\u0101rst\u012bbu diagrammas<\/li>\n<li><a href=\"https:\/\/vibromera.eu\/lv\/glossary\/phase-angle\/\">F\u0101zes le\u0146\u0137is<\/a> m\u0113r\u012bjumu diapazons 0\u2013360\u00b0 (precizit\u0101te \u00b11\u00b0)<\/li>\n<li>Ieb\u016bv\u0113ts <a href=\"https:\/\/vibromera.eu\/lv\/glossary\/tachometer\/\">tahometrs<\/a> ievades<\/li>\n<li>\u2013 Ilgm\u016b\u017e\u012bgs uzl\u0101d\u0113jams akumulators (10\u201312 darba stundas)<\/li>\n<\/ul>\n<p>\u0160\u0101da funkciju kombin\u0101cija \u013cauj speci\u0101listiem veikt piln\u012bgu vibr\u0101cijas anal\u012bzi un balans\u0113\u0161anu uz vietas \u2014 nepiesl\u0113dzoties \u0101r\u0113jiem datoriem vai baro\u0161anas avotiem.<\/p>\n<div id=\"attachment_1877\" style=\"width: 756px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1877\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1.webp\" alt=\"P\u0101rn\u0113s\u0101jamais vibr\u0101cijas analizators ArBalance\" width=\"746\" height=\"496\" class=\"size-full wp-image-1877\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1.webp 746w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-600x399.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-300x199.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-360x240.webp 360w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-272x182.webp 272w\" sizes=\"auto, (max-width: 746px) 100vw, 746px\" \/><p id=\"caption-attachment-1877\" class=\"wp-caption-text\">P\u0101rn\u0113s\u0101jamais vibr\u0101cijas analizators ArBalance<\/p><\/div>\n<div id=\"attachment_1879\" style=\"width: 329px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1879\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal3ssw1-1.webp\" alt=\"Vibr\u0101cijas analizators ArBalance\" width=\"319\" height=\"386\" class=\"size-full wp-image-1879\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal3ssw1-1.webp 319w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal3ssw1-1-248x300.webp 248w\" sizes=\"auto, (max-width: 319px) 100vw, 319px\" \/><p id=\"caption-attachment-1879\" class=\"wp-caption-text\">Vibr\u0101cijas analizators ArBalance<\/p><\/div>\n<div id=\"attachment_1878\" style=\"width: 330px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1878\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal4ssw-1.webp\" alt=\"Vibr\u0101ciju grafiki un spektr\u0101l\u0101 anal\u012bze\" width=\"320\" height=\"445\" class=\"size-large wp-image-1878\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal4ssw-1.webp 320w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal4ssw-1-216x300.webp 216w\" sizes=\"auto, (max-width: 320px) 100vw, 320px\" \/><p id=\"caption-attachment-1878\" class=\"wp-caption-text\">Vibr\u0101ciju grafiki un spektr\u0101l\u0101 anal\u012bze<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>Portable vibrometer balancer ArBalance During the balancing of the Fecon forestry mulcher with the FAE attachment, our specialist recorded short videos showing the rotor balancing process. ArBalance and the Balanset-1A: A Shared Platform In this demonstration, a portable vibration analyzer ArBalance was used. The procedure follows the same principle as [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1877,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ai_generated_summary":"","footnotes":""},"categories":[4,54],"tags":[],"class_list":["post-2234","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-example","category-content"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/posts\/2234","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/comments?post=2234"}],"version-history":[{"count":3,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/posts\/2234\/revisions"}],"predecessor-version":[{"id":101517,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/posts\/2234\/revisions\/101517"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/media\/1877"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/media?parent=2234"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/categories?post=2234"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vibromera.eu\/lv\/wp-json\/wp\/v2\/tags?post=2234"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}