{"id":101581,"date":"2026-05-30T21:41:00","date_gmt":"2026-05-30T21:41:00","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101581"},"modified":"2026-07-02T19:11:15","modified_gmt":"2026-07-02T19:11:15","slug":"vibration-analyzer","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/ro\/balancing-catalog\/vibration-analyzer\/","title":{"rendered":"Analizor de vibra\u021bii \u0219i spectru FFT - Balanset-1A"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/ro\/balancing-catalog\/\">Servicii de echilibrare<\/a> &rsaquo; Analizor de vibra\u021bii<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Analizor de vibra\u021bii - spectru FFT pe dou\u0103 canale, faz\u0103 \u0219i diagnosticare defec\u021biuni<\/h1>\n<p class=\"lede\">Balanset-1A este un analizor de vibra\u021bii cu dou\u0103 canale care traseaz\u0103 spectre FFT \u00een timp real, m\u0103soar\u0103 amplitudinea \u0219i faza la 1\u00d7 RPM \u0219i cartografiaz\u0103 semn\u0103turile defectelor pentru a distinge dezechilibrul, dezaliniamentul, sl\u0103birea \u0219i deteriorarea rulmen\u021bilor - apoi echilibreaz\u0103 \u00een aceea\u0219i sesiune. Un kit portabil de 1 975 EUR acoper\u0103 diagnosticarea, corectarea \u0219i verificarea f\u0103r\u0103 a schimba instrumentele.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/ro\/balanset-1a\/\">Ob\u021bine\u021bi Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/ro\/community\/\">\u00centreba\u021bi-l pe inginerul nostru<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/02\/interface-1-e1518391488191.webp\" alt=\"Analizor de vibra\u021bii Balanset-1A interfa\u021b\u0103 spectru FFT pe laptop\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Pe scurt:<\/b> Analizorul de vibra\u021bii Balanset-1A capteaz\u0103 semnale simultane pe dou\u0103 canale de la cei doi senzori de vibra\u021bii ai s\u0103i (accelerometre MEMS analogice), calculeaz\u0103 un spectru FFT \u00een timp real \u0219i afi\u0219eaz\u0103 amplitudinea \u0219i faza la fiecare armonic\u0103 de ordin al arborelui. Dezechilibrul apare ca un v\u00e2rf dominant la 1&times; RPM; nealinierea ca \u0219i componente ridicate la 2&times; \u0219i 3&times;; defectele dezvoltate ale rulmen\u021bilor ca v\u00e2rfuri BPFO\/BPFI \u0219i benzi laterale; sl\u0103birea ca subarmonici. Deoarece acela\u0219i hardware \u0219i aceia\u0219i senzori sunt utiliza\u021bi pentru echilibrarea \u00een teren, diagnostica\u021bi defectul, \u00eel corecta\u021bi \u0219i verifica\u021bi rezultatul \u00eentr-o singur\u0103 vizit\u0103 la fa\u021ba locului &mdash; m\u0103sur\u00e2nd viteza vibra\u021biilor de la 0.2 la 80&nbsp;mm\/s \u00een intervalul 5 p\u00e2n\u0103 la 1000&nbsp;Hz.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#when\">C\u00e2nd s\u0103 analiza\u021bi<\/a><br \/>\n<a href=\"#measures\">Ce m\u0103soar\u0103<\/a><br \/>\n<a href=\"#faults\">Diagnosticarea defec\u021biunilor<\/a><br \/>\n<a href=\"#how\">Cum se utilizeaz\u0103<\/a><br \/>\n<a href=\"#standards\">Standarde<\/a><br \/>\n<a href=\"#device\">Balanset-1A<\/a><br \/>\n<a href=\"#screenshots\">Capturi de ecran<\/a><br \/>\n<a href=\"#cases\">Cazuri reale<\/a><br \/>\n<a href=\"#calc\">Calculatoare<\/a><br \/>\n<a href=\"#faq\">\u00ceNTREB\u0102RI FRECVENTE<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"when\">\n<h2>Semne c\u0103 utilajul dvs. are nevoie de o analiz\u0103 a vibra\u021biilor, nu doar de o citire a contorului<\/h2>\n<p>Un singur num\u0103r global de vibra\u021bii v\u0103 spune c\u0103 ceva nu este \u00een regul\u0103. Un spectru FFT v\u0103 spune ce \u0219i de ce. Aceste situa\u021bii necesit\u0103 un analizor adecvat:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Cauza vibra\u021biilor necunoscut\u0103<\/b> Nivelul general este ridicat, dar nu pute\u021bi spune dac\u0103 vinovatul este dezechilibrul, nealinierea, sl\u0103birea sau deteriorarea rulmentului - FFT separ\u0103 fiecare semn\u0103tur\u0103.<\/div>\n<div><b>Component\u0103 puternic\u0103 1\u00d7 RPM<\/b> Un v\u00e2rf dominant de ordinul \u00eent\u00e2i este semn\u0103tura clasic\u0103 a dezechilibrului rezidual al rotorului \u0219i declan\u0219atorul procedurii de echilibrare.<\/div>\n<div><b>Armonice 2\u00d7 sau 3\u00d7 crescute<\/b> O component\u0103 pronun\u021bat\u0103 de ordinul al doilea sau al treilea indic\u0103, de obicei, o nealiniere unghiular\u0103 sau paralel\u0103 a cuplajelor sau arborilor.<\/div>\n<div><b>Subarmonici sau zgomot \u00een band\u0103 larg\u0103<\/b> Frecven\u021bele joase ale defectelor de rulment (BPFO, BPFI, BSF, FTF) \u0219i armonicile lor apar \u00een spectrul de vitez\u0103 pe m\u0103sur\u0103 ce defectul se dezvolt\u0103 &mdash; un avertisment care merit\u0103 urm\u0103rit \u00een trend \u00eenainte de avarie, de\u0219i stadiul foarte timpuriu al deterior\u0103rii necesit\u0103 analiz\u0103 \u00een anvelop\u0103 la frecven\u021be \u00eenalte.<\/div>\n<div><b>Verificarea recep\u021biei post-reparare<\/b> Dup\u0103 echilibrare, aliniere sau schimbarea unui rulment, ave\u021bi nevoie de dovada m\u0103surat\u0103 c\u0103 nivelurile au sc\u0103zut sub limita de acceptare ISO 20816.<\/div>\n<div><b>Anchet\u0103 periodic\u0103 de monitorizare a st\u0103rii<\/b> \u00cenregistrarea spectrelor de referin\u021b\u0103 la intervale regulate v\u0103 permite s\u0103 urm\u0103ri\u021bi tendin\u021bele de cre\u0219tere a amplitudinilor \u0219i s\u0103 planifica\u021bi \u00eentre\u021binerea \u00eenainte de o oprire neplanificat\u0103.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"measures\">\n<h2>Ce m\u0103soar\u0103 analizorul Balanset-1A<\/h2>\n<p>Analizorul capteaz\u0103 semnale simultane de la cei doi senzori de vibra\u021bii furniza\u021bi (accelerometre MEMS analogice), referen\u021biate la tahometrul laser. Fiecare parametru listat mai jos este disponibil \u00eentr-o singur\u0103 achizi\u021bie:<\/p>\n<ul class=\"vbm-list\">\n<li>Viteza global\u0103 a vibra\u021biilor (mm\/s RMS) \u0219i accelera\u021bia (m\/s\u00b2 sau g)<\/li>\n<li>Spectru de frecven\u021b\u0103 FFT \u00een timp real cu rezolu\u021bie selectabil\u0103 de utilizator<\/li>\n<li>Forma de und\u0103 a vibra\u021biei (semnal \u00een domeniul timpului) pe ambele canale simultan<\/li>\n<li>Unghiul de faz\u0103 la 1\u00d7 RPM \u00een raport cu referin\u021ba tahometrului arborelui<\/li>\n<li>Amplitudini de 1\u00d7, 2\u00d7, 3\u00d7 \u0219i de ordin superior ale arborelui extrase din FFT<\/li>\n<li>Achizi\u021bie simultan\u0103 pe dou\u0103 canale (ambele planuri ale lag\u0103relor simultan)<\/li>\n<li>Viteza de rulare (RPM) de la tahometrul optic cu laser - nu este necesar\u0103 o plac\u0103 de identificare<\/li>\n<li>Jurnalul tendin\u021belor de vibra\u021bie pe m\u0103sur\u0103tori succesive<\/li>\n<li>Raport tip\u0103rit: form\u0103 de und\u0103, spectru \u0219i rezumat numeric<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>up to &times;10<\/b><span>durata de via\u021b\u0103 a rulmentului atunci c\u00e2nd sarcina de dezechilibru este \u00eenjum\u0103t\u0103\u021bit\u0103 (ISO 281)<\/span><\/div>\n<div class=\"vbm-stat\"><b>-70%<\/b><span>sc\u0103dere tipic\u0103 a vibra\u021biilor dup\u0103 o sesiune de echilibrare<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>canale, achizi\u021bie simultan\u0103<\/span><\/div>\n<div class=\"vbm-stat\"><b>5&ndash;1000&nbsp;Hz<\/b><span>gama de frecven\u021be a analizorului<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"faults\">\n<h2>Diagnosticarea defec\u021biunilor - citirea spectrului FFT<\/h2>\n<p>Fiecare defec\u021biune mecanic\u0103 las\u0103 o amprent\u0103 spectral\u0103 distinct\u0103. Tabelul de mai jos asociaz\u0103 cele mai frecvente defec\u021biuni cu semn\u0103turile lor spectrale, astfel \u00eenc\u00e2t s\u0103 pute\u021bi citi starea ma\u0219inii direct de pe afi\u0219ajul Balanset-1A.<\/p>\n<table class=\"vbm-table\">\n<caption>Ghid de diagnosticare a defectelor de vibra\u021bii - semn\u0103turi spectrale<\/caption>\n<thead>\n<tr>\n<th>Defect<\/th>\n<th>Componente spectrale dominante<\/th>\n<th>Al\u021bi indicatori<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><b>Dezechilibrul rotorului<\/b><\/td>\n<td>1\u00d7 RPM puternic; toate celelalte ordine sc\u0103zute<\/td>\n<td>Faza este stabil\u0103; amplitudinea cre\u0219te odat\u0103 cu p\u0103tratul vitezei; confirmat\u0103 prin testul cu greutate de prob\u0103<\/td>\n<\/tr>\n<tr>\n<td><b>Nealiniere unghiular\u0103<\/b><\/td>\n<td>Ridicat 1\u00d7 \u0219i 2\u00d7; uneori 3\u00d7<\/td>\n<td>Vibra\u021bia axial\u0103 este adesea egal\u0103 sau mai mare dec\u00e2t cea radial\u0103; diferen\u021ba de faz\u0103 \u00een cuplaj \u2248180\u00b0<\/td>\n<\/tr>\n<tr>\n<td><b>Nealiniere paralel\u0103<\/b><\/td>\n<td>2\u00d7 RPM puternic; 1\u00d7 poate fi de asemenea prezent<\/td>\n<td>Vibra\u021bii radiale ridicate; deplasare de faz\u0103 de 180\u00b0 m\u0103surat\u0103 \u00een direc\u021bia radial\u0103 prin cuplaj<\/td>\n<\/tr>\n<tr>\n<td><b>Joc mecanic<\/b><\/td>\n<td>Subarmonici (0,5\u00d7, 0,33\u00d7) \u0219i armonici multiple de p\u00e2n\u0103 la 10\u00d7<\/td>\n<td>Nivelul de zgomot \u00een band\u0103 larg\u0103 este ridicat; simptomele se agraveaz\u0103 cu sarcina<\/td>\n<\/tr>\n<tr>\n<td><b>Uzura rulmen\u021bilor cu elemente rulante<\/b><\/td>\n<td>Frecven\u021bele de defect BPFO, BPFI, BSF sau FTF \u0219i armonicele acestora<\/td>\n<td>Poate ap\u0103rea \u00eenainte de cre\u0219terea nivelului general; benzile laterale din jurul frecven\u021belor defecte confirm\u0103 progresia<\/td>\n<\/tr>\n<tr>\n<td><b>Rezonan\u0163\u0103<\/b><\/td>\n<td>Amplitudine mare \u00een apropierea unei frecven\u021be naturale, adesea nu sincron\u0103 cu RPM<\/td>\n<td>Amplitudinea atinge un v\u00e2rf la o anumit\u0103 vitez\u0103; faza se modific\u0103 cu ~180\u00b0 prin rezonan\u021b\u0103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Atunci c\u00e2nd componenta 1\u00d7 domin\u0103, trece\u021bi direct la modul de echilibrare - Balanset-1A utilizeaz\u0103 aceea\u0219i serie de m\u0103sur\u0103tori ca referin\u021b\u0103 pentru calculul coeficientului de influen\u021b\u0103, astfel \u00eenc\u00e2t nu se pierde timp.<\/p>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>De ce o singur\u0103 cifr\u0103 global\u0103 rateaz\u0103 defectul<\/h2>\n<p>Un stilou de vibra\u021bii sau un contor RMS simplu \u00eensumeaz\u0103 toate componentele de frecven\u021b\u0103 \u00eentr-un singur num\u0103r. Dou\u0103 ma\u0219ini pot afi\u0219a niveluri generale identice \u0219i totu\u0219i s\u0103 aib\u0103 defec\u021biuni complet diferite - una dominat\u0103 de un dezechilibru de 1\u00d7, cealalt\u0103 de benzi laterale ale defectelor rulmen\u021bilor. F\u0103r\u0103 rezolu\u021bia frecven\u021bei, ghici\u021bi cauza \u0219i risca\u021bi s\u0103 aplica\u021bi un remediu gre\u0219it. FFT descompune semnalul astfel \u00eenc\u00e2t fiecare tip de defect s\u0103 apar\u0103 ca un v\u00e2rf etichetat la frecven\u021ba sa caracteristic\u0103, oferindu-v\u0103 at\u00e2t un diagnostic, c\u00e2t \u0219i o re\u021bet\u0103 \u00een aceea\u0219i m\u0103sur\u0103toare.<\/p>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> arat\u0103 de ce diagnosticul conteaz\u0103 din punct de vedere financiar. Durata de via\u021b\u0103 nominal\u0103 de baz\u0103 a rulmen\u021bilor cu elemente de rostogolire este <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b> (\u00een milioane de rota\u021bii), unde P este sarcina dinamic\u0103 echivalent\u0103 a rulmentului \u0219i p = 3 pentru rulmen\u021bii cu bile (10\/3 pentru rulmen\u021bii cu role). Dezechilibrul rezidual adaug\u0103 o component\u0103 rotativ\u0103 acestei sarcini, astfel \u00eenc\u00e2t \u00eenjum\u0103t\u0103\u021birea amplitudinii vibra\u021biei 1&times; \u00eenjum\u0103t\u0103\u021be\u0219te aproximativ sarcina de dezechilibru; acolo unde aceast\u0103 sarcin\u0103 rotativ\u0103 domin\u0103 P, durata de via\u021b\u0103 a rulmentului se multiplic\u0103 cu p\u00e2n\u0103 la 2<sup>p<\/sup>: aproximativ <b>8\u00d7 pentru rulmen\u021bii cu bile \u0219i ~10\u00d7 pentru rulmen\u021bii cu role<\/b>. Estimarea este valabil\u0103 numai atunci c\u00e2nd vibra\u021bia m\u0103surat\u0103 la 1&times; este un indicator rezonabil al sarcinii dinamice rotative din rulment. Utiliza\u021bi <a href=\"https:\/\/vibromera.eu\/ro\/calculators\/bearing-load\/\">calculator de durat\u0103 de via\u021b\u0103 a rulmen\u021bilor<\/a> pentru a cuantifica economiile pentru ma\u0219ina dumneavoastr\u0103.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>Cum s\u0103 utiliza\u021bi Balanset-1A ca analizor de vibra\u021bii - pas cu pas<\/h2>\n<ol class=\"vbm-steps\">\n<li><b>Monta\u021bi senzorii.<\/b> Ata\u0219a\u021bi unul sau ambii senzori de vibra\u021bii pe carcasele rulmen\u021bilor folosind suporturile magnetice. Pentru analiza cu referin\u021b\u0103 de faz\u0103, fixa\u021bi banda reflectorizant\u0103 a tahometrului laser pe arborele rotativ \u0219i orienta\u021bi senzorul c\u0103tre aceasta (distan\u021b\u0103 de lucru 50&ndash;500&nbsp;mm). Ambele canale \u00eenregistreaz\u0103 simultan.<\/li>\n<li><b>Porni\u021bi rotorul \u0219i achizi\u021biona\u021bi.<\/b> Deschide\u021bi software-ul Balanset, selecta\u021bi <em>Analizor<\/em> \u0219i \u00eencepe\u021bi achizi\u021bia. Software-ul afi\u0219eaz\u0103 forma de und\u0103 live, spectrul FFT \u0219i nivelul global al vibra\u021biilor RMS \u00een mm\/s \u00een timp real pe un laptop Windows standard.<\/li>\n<li><b>Citi\u021bi spectrul.<\/b> Identifica\u021bi v\u00e2rfurile de frecven\u021b\u0103 dominante. Amplitudinea \u0219i faza de ordinul \u00eent\u00e2i sunt afi\u0219ate automat \u00een raport cu impulsul tahometrului. Consulta\u021bi tabelul de defec\u021biuni de mai sus pentru a potrivi modelul spectral cu cel mai probabil tip de defec\u021biune.<\/li>\n<li><b>Compara\u021bi cu limitele de acceptare.<\/b> Verifica\u021bi citirea vitezei globale \u00een raport cu valorile relevante <b>ISO 20816<\/b> limita zonei (A\/B\/C\/D) pentru clasa ma\u0219inii \u0219i puterea nominal\u0103. Exporta\u021bi diagrama spectral\u0103 \u0219i valorile numerice pentru raportul de \u00eentre\u021binere.<\/li>\n<li><b>Dac\u0103 dezechilibrul este confirmat, echilibra\u021bi \u00een aceea\u0219i sesiune.<\/b> M\u0103surarea de referin\u021b\u0103 deja capturat\u0103 serve\u0219te drept prima rulare \u00een secven\u021ba coeficientului de influen\u021b\u0103. Ad\u0103uga\u021bi o greutate de prob\u0103, efectua\u021bi o nou\u0103 analiz\u0103 \u0219i l\u0103sa\u021bi software-ul s\u0103 calculeze corec\u021bia - f\u0103r\u0103 instrumente suplimentare, f\u0103r\u0103 a doua vizit\u0103.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Standarde de m\u0103surare a vibra\u021biilor<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 20816<\/b> define\u0219te zonele de evaluare a vitezei de vibra\u021bie (mm\/s RMS) pentru piesele care nu se rotesc: Zona A (nou pus\u0103 \u00een func\u021biune), B (acceptabil\u0103 pentru func\u021bionare pe termen lung), C (alarm\u0103 - investiga\u021bie imediat\u0103), D (pericol - risc de deteriorare). Limitele variaz\u0103 \u00een func\u021bie de clasa ma\u0219inii \u0219i de \u00een\u0103l\u021bimea centrului arborelui. Balanset-1A raporteaz\u0103 viteza total\u0103 \u00een mm\/s RMS, astfel \u00eenc\u00e2t s\u0103 pute\u021bi compara direct cu partea ISO 20816 relevant\u0103 pentru tipul dumneavoastr\u0103 de ma\u0219in\u0103.<\/p>\n<p>Odat\u0103 ce dezechilibrul este identificat, dezechilibrul rezidual dup\u0103 echilibrare este evaluat \u00een raport cu <b>ISO 21940-11<\/b> Gradele G (de la G0,4 la G40). Balanset-1A documenteaz\u0103 dezechilibrul rezidual ob\u021binut \u00een raportul s\u0103u tip\u0103rit, oferindu-v\u0103 o \u00eenregistrare verificabil\u0103 \u00een raport cu standardul aplicabil. Utiliza\u021bi <a href=\"https:\/\/vibromera.eu\/ro\/calculators\/residual-unbalance-iso1940\/\">calculator de dezechilibru rezidual<\/a> pentru a afla toleran\u021ba admis\u0103 \u00eenainte de a \u00eencepe.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A - analizorul de c\u00e2mp complet \u0219i trusa de echilibrare<\/h2>\n<p>Totul pe aceast\u0103 pagin\u0103 este realizat cu un singur instrument portabil: <a href=\"https:\/\/vibromera.eu\/ro\/balanset-1a\/\">Balanset-1A<\/a>. Este un dispozitiv de echilibrare dinamic\u0103 cu dou\u0103 canale \u0219i un analizor de vibra\u021bii care diagnosticheaz\u0103 defec\u021biunile din spectrul FFT \u0219i, atunci c\u00e2nd dezechilibrul este confirmat, echilibreaz\u0103 rotoarele rigide <strong>\u00een propriile rulmen\u021bi, la viteza de func\u021bionare<\/strong>, folosind metoda coeficientului de influen\u021b\u0103 cu 3 serii &mdash; software-ul calculeaz\u0103 masa \u0219i unghiul de corec\u021bie exacte \u0219i salveaz\u0103 un raport.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Kit complet de echilibrare Balanset-1A cu senzori, tahometru laser, c\u00e2ntar \u0219i cutie\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Ce con\u021bine kitul complet<\/h3>\n<p class=\"price\">1.975 \u20ac <span>&middot; Kit complet, \u00een stoc, factur\u0103 cu TVA<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Unitate de m\u0103surare a interfe\u021bei (USB, 2 canale)<\/li>\n<li>Dou\u0103 accelerometre de vibra\u021bii (cablu de 4&nbsp;m, 10&nbsp;m op\u021bional)<\/li>\n<li>Tahometru laser \/ senzor optic de faz\u0103 (50&ndash;500&nbsp;mm)<\/li>\n<li>Suport magnetic pentru senzor<\/li>\n<li>C\u00e2ntar digital pentru greut\u0103\u021bi de prob\u0103 \u0219i corec\u021bie<\/li>\n<li>Software de echilibrare \u0219i analiz\u0103 Windows<\/li>\n<li>Valiz\u0103 de transport din plastic<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/ro\/balanset-1a\/\">Vizualiza\u021bi Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/ro\/community\/\">\u00centreba\u021bi-l pe inginerul nostru<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Recomandat<\/span><\/p>\n<h3>Kit complet<\/h3>\n<p>Unitate - 2 senzori - tahometru laser - suport magnetic - c\u00e2ntar digital - software - geant\u0103 de transport. Tot ce este necesar pentru a \u00eencepe analiza \u0219i echilibrarea din cutie.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM (Original Equipment Manufacturer)<\/span><\/p>\n<h3>Set OEM<\/h3>\n<p>Unitate &middot; 2 senzori &middot; tahometru laser &middot; software. Pentru integratorii care au deja un stand, un c\u00e2ntar \u0219i o carcas\u0103 sau care integreaz\u0103 unitatea \u00eentr-o ma\u0219in\u0103 de echilibrat.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Specifica\u021bii tehnice cheie<\/caption>\n<thead>\n<tr>\n<th>Parametru<\/th>\n<th>Valoare<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Canale de m\u0103surare<\/td>\n<td>2 (echilibrare pe un singur plan &amp; pe dou\u0103)<\/td>\n<\/tr>\n<tr>\n<td>Intervalul vitezei de vibra\u021bie<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Interval de frecven\u021b\u0103<\/td>\n<td>5&ndash;1000 Hz (&le;10% eroare de amplitudine peste 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>Precizia m\u0103sur\u0103rii<\/td>\n<td>&plusmn;5% din scala complet\u0103<\/td>\n<\/tr>\n<tr>\n<td>Metod\u0103<\/td>\n<td>Coeficient de influen\u021b\u0103 cu 3 runde (1 sau 2 planuri)<\/td>\n<\/tr>\n<tr>\n<td>Analiz\u0103<\/td>\n<td>Amplitudine \u0219i faz\u0103 la 1&times;, spectru FFT \u0219i form\u0103 de und\u0103, rapoarte salvate<\/td>\n<\/tr>\n<tr>\n<td>Laptop<\/td>\n<td>Nu este inclus (Windows PC, disponibil la cerere)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>&#10003;<\/b> \u00cen stoc<\/span><span><b>&#10003;<\/b> DHL Portugalia &euro;35<\/span><span><b>&#10003;<\/b> DHL \u00een \u00eentreaga lume &euro;110<\/span><span><b>&#10003;<\/b> Garan\u021bie de 2 ani<\/span><span><b>&#10003;<\/b> Factura TVA<\/span><span><b>&#10003;<\/b> Asisten\u021b\u0103 pentru ingineri<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"screenshots\">\n<h2>Ce arat\u0103 analizorul Balanset-1A<\/h2>\n<div class=\"vbm-cases\">\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/ChatGPT-Image-25-%D0%B8%D1%8E%D0%BB.-2025-%D0%B3.-22_07_35.webp\" alt=\"Analizor de vibra\u021bii cu dou\u0103 canale Balanset-1A ecran de prezentare\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Prezentare general\u0103 a analizorului cu dou\u0103 canale<\/h3>\n<p>Nivelul global al vibra\u021biilor, spectrul FFT \u0219i unghiul de faz\u0103 de la doi senzori afi\u0219ate simultan pe un laptop Windows.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/09\/Screenshot-2025-07-29-165701-scaled.webp\" alt=\"Spectrul FFT \u00een timp real care arat\u0103 v\u00e2rfurile de frecven\u021b\u0103 pentru diagnosticarea defec\u021biunilor\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Spectru FFT \u00een timp real<\/h3>\n<p>V\u00e2rfurile de frecven\u021b\u0103 disting dezechilibrul (dominant 1\u00d7) de nealiniere (2\u00d7) \u0219i de benzile laterale ale defectelor de rulment.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/10\/%D0%98%D0%B7%D0%BE%D0%B1%D1%80%D0%B0%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-WhatsApp-2025-10-03-%D0%B2-11.16.33_1bc14f9b.webp\" alt=\"Accelerometru \u0219i tahometru laser montate pe carcasa rulmentului pe teren\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>M\u0103surarea \u00een teren<\/h3>\n<p>Senzor de vibra\u021bii \u0219i tahometru laser montate pe carcasa rulmentului unei ma\u0219ini aflate \u00een func\u021biune &mdash; nu este necesar\u0103 demontarea ma\u0219inii.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10461221.webp\" alt=\"Amplitudinea \u0219i faza la 1x RPM afi\u0219ate \u00een software-ul Balanset\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Amplitudine \u0219i faz\u0103 la 1\u00d7<\/h3>\n<p>Amplitudinea de ordinul \u00eent\u00e2i \u0219i unghiul de faz\u0103 afi\u0219ate fa\u021b\u0103 de referin\u021ba tahometrului - intr\u0103rile necesare pentru echilibrarea coeficientului de influen\u021b\u0103.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-case\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2024\/02\/Bs1ManualEngV156-May2023-10418068.webp\" alt=\"Raport de m\u0103surare Balanset-1A imprimabil cu form\u0103 de und\u0103 \u0219i spectru\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Raport documentat<\/h3>\n<p>Forma de und\u0103, spectrul FFT \u0219i rezumatul numeric exportate ca un raport imprimabil pentru dosarul de \u00eentre\u021binere.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Cazuri reale de m\u0103surare \u0219i analizare<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/ro\/exemplu\/masurarea-vibratiilor-relative-ale-rotorului-cu-ajutorul-senzorilor-de-deplasare-liniara-fara-contact\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/image014.webp\" alt=\"M\u0103surarea f\u0103r\u0103 contact a vibra\u021biilor cu senzori de deplasare liniar\u0103\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>M\u0103surarea vibra\u021biilor f\u0103r\u0103 contact<\/h3>\n<p>Utilizarea senzorilor de deplasare liniar\u0103 pentru a m\u0103sura vibra\u021bia relativ\u0103 a rotorului f\u0103r\u0103 contact cu arborele - adecvat pentru rotoarele \u00een care montarea accelerometrului nu este practic\u0103.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/ro\/exemplu\/portabil-balansator-vibratie-analizator-si-balansator-masina-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/photo_2023-04-08_17-03-49-1024x576.webp\" alt=\"Balanset-1A utilizat at\u00e2t ca analizor de vibra\u021bii, c\u00e2t \u0219i ca dispozitiv de echilibrare \u00een dou\u0103 planuri\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Analizor \u0219i dispozitiv de echilibrare combinate<\/h3>\n<p>O demonstra\u021bie practic\u0103 a modului \u00een care un dispozitiv acoper\u0103 analiza vibra\u021biilor \u0219i echilibrarea \u00een dou\u0103 planuri \u00eentr-o singur\u0103 lucrare, de la diagnosticare la corec\u021bia verificat\u0103.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/ro\/exemplu\/why-balancing-doesnt-reduce-vibration-troubleshooting-guide-balanset-1a\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2025\/06\/ChatGPT-Image-19-%D0%B8%D1%8E%D0%BD.-2025-%D0%B3.-18_31_25.webp\" alt=\"Diagnosticarea motivului pentru care echilibrarea nu reduce vibra\u021biile cu ajutorul analizorului\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Diagnostica\u021bi \u00eenainte de a echilibra<\/h3>\n<p>Un ghid de depanare pentru cazurile \u00een care echilibrarea singur\u0103 nu reduce vibra\u021biile &mdash; \u0219i cum spectrul FFT dezv\u0103luie cauza principal\u0103 real\u0103.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Calculatoare de vibra\u021bii gratuite<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/ro\/calculators\/bearing-load\/\">Calculator de durat\u0103 de via\u021b\u0103 a rulmen\u021bilor<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/ro\/calculators\/centrifugal-force-unbalance\/\">For\u021ba centrifug\u0103 din cauza dezechilibrului<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/ro\/calculators\/residual-unbalance-iso1940\/\">Dezechilibru rezidual (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/ro\/calculators\/trial-weight-calculator\/\">Calculator de greutate de prob\u0103<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>\u00centreb\u0103ri frecvente despre analizorul de vibra\u021bii<\/h2>\n<details>\n<summary>Cum distinge analiza FFT dezechilibrul de nealiniere?<\/summary>\n<div class=\"ans\">Dezechilibrul produce un singur v\u00e2rf dominant la exact 1\u00d7 viteza de rulare. Dezalinierea unghiular\u0103 prezint\u0103 de obicei o component\u0103 puternic\u0103 de 2\u00d7 \u0219i uneori de 3\u00d7, adesea cu vibra\u021bii axiale ridicate. Nealinierea paralel\u0103 produce un v\u00e2rf radial proeminent de 2\u00d7. Balanset-1A eticheteaz\u0103 automat aceste v\u00e2rfuri \u00een afi\u0219ajul FFT, astfel \u00eenc\u00e2t s\u0103 pute\u021bi identifica defec\u021biunea dominant\u0103 \u00eenainte de a decide asupra unei corec\u021bii. Dac\u0103 domin\u0103 componenta 1\u00d7, aceea\u0219i serie de m\u0103sur\u0103tori se transfer\u0103 direct \u00een calculul de echilibrare.<\/div>\n<\/details>\n<details>\n<summary>Pot utiliza Balanset-1A ca analizor independent f\u0103r\u0103 echilibrare?<\/summary>\n<div class=\"ans\">Da. Dispozitivul func\u021bioneaz\u0103 doar \u00een modul analizor pentru a \u00eenregistra spectrele de vibra\u021bii, a m\u0103sura nivelurile generale \u00een mm\/s \u0219i a \u00eenregistra datele pentru monitorizarea tendin\u021belor de stare &mdash; f\u0103r\u0103 a intra \u00een modul de echilibrare. Acest lucru este util pentru inspec\u021bia la sosire, studiile periodice privind starea \u0219i m\u0103sur\u0103torile de acceptare post-reparare \u00een raport cu limitele ISO 20816.<\/div>\n<\/details>\n<details>\n<summary>Ce gam\u0103 de frecven\u021be acoper\u0103 FFT \u0219i este aceasta suficient\u0103 pentru diagnosticarea rulmen\u021bilor?<\/summary>\n<div class=\"ans\">Balanset-1A acoper\u0103 intervalul 5 p\u00e2n\u0103 la 1000&nbsp;Hz, care include toate armonicile de ordin ale arborelui, plus frecven\u021bele fundamentale ale defectelor de rulment (BPFO, BPFI, BSF, FTF) \u0219i armonicile lor inferioare pentru majoritatea rulmen\u021bilor industriali cu elemente de rostogolire la viteze tipice. Totu\u0219i, \u021bine\u021bi cont de limit\u0103: deteriorarea de stadiu incipient a rulmen\u021bilor este detectat\u0103 \u00een mod normal prin tehnici de accelera\u021bie de \u00eenalt\u0103 frecven\u021b\u0103 \u0219i analiz\u0103 \u00een anvelop\u0103 (demodulare), care necesit\u0103 o l\u0103\u021bime de band\u0103 de la c\u00e2\u021biva kHz p\u00e2n\u0103 la zeci de kHz &mdash; dincolo de domeniul acestui instrument. \u00cen intervalul 5&ndash;1000&nbsp;Hz, Balanset-1A eviden\u021biaz\u0103 defectele de rulment atunci c\u00e2nd acestea produc componente m\u0103surabile de vitez\u0103 la frecven\u021bele defectului, adic\u0103 \u00eentr-un stadiu mai avansat; nu \u00eenlocuie\u0219te un instrument dedicat de diagnosticare a rulmen\u021bilor, cu band\u0103 larg\u0103.<\/div>\n<\/details>\n<details>\n<summary>ISO 20816 se aplic\u0103 ma\u0219inii mele?<\/summary>\n<div class=\"ans\">ISO 20816 acoper\u0103 o gam\u0103 larg\u0103 de ma\u0219ini rotative \u00een p\u0103r\u021bile lor multiple: pompe, compresoare, ventilatoare, turbine, motoare \u0219i generatoare sunt toate vizate. Limita specific\u0103 a zonei depinde de clasa de putere a ma\u0219inii \u0219i de \u00een\u0103l\u021bimea centrului arborelui. Balanset-1A raporteaz\u0103 viteza total\u0103 \u00een mm\/s RMS, astfel \u00eenc\u00e2t s\u0103 aplica\u021bi direct la citire orice parte din ISO 20816 care se refer\u0103 la tipul dumneavoastr\u0103 de ma\u0219in\u0103.<\/div>\n<\/details>\n<details>\n<summary>M\u0103surarea fazei este suficient de precis\u0103 pentru echilibrarea pe dou\u0103 planuri?<\/summary>\n<div class=\"ans\">Da. Faza este m\u0103surat\u0103 \u00een raport cu impulsul tahometrului optic, oferind o referin\u021b\u0103 unghiular\u0103 repetabil\u0103. Achizi\u021bia simultan\u0103 pe dou\u0103 canale asigur\u0103 c\u0103 ambele planuri ale rulmen\u021bilor sunt e\u0219antionate \u00een aceea\u0219i pozi\u021bie a arborelui, ceea ce este esen\u021bial pentru calcularea exact\u0103 a efectului \u00eencruci\u0219at (coeficient de influen\u021b\u0103) \u00een lucr\u0103rile de echilibrare dinamic\u0103 pe dou\u0103 planuri.<\/div>\n<\/details>\n<details>\n<summary>Cum ajut\u0103 analizorul atunci c\u00e2nd echilibrarea singur\u0103 nu a rezolvat problema vibra\u021biilor?<\/summary>\n<div class=\"ans\">Atunci c\u00e2nd echilibrarea reduce componenta 1\u00d7, dar vibra\u021bia general\u0103 r\u0103m\u00e2ne ridicat\u0103, FFT arat\u0103 imediat ce alt\u0103 component\u0103 de frecven\u021b\u0103 a devenit dominant\u0103 &mdash; fie o armonic\u0103 2\u00d7 de nealiniere, o frecven\u021b\u0103 de defect a rulmentului sau o semn\u0103tur\u0103 subarmonic\u0103 de sl\u0103bire. Acest lucru direc\u021bioneaz\u0103 cu precizie urm\u0103torul pas corectiv, \u00een loc s\u0103 lase tehnicianul s\u0103 ghiceasc\u0103. Consulta\u021bi studiul nostru de caz privind diagnosticarea vibra\u021biilor persistente pentru exemple practice.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>\u00cenv\u0103\u021ba\u021bi teoria<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/ro\/glossary\/echilibrarea-campului\/\">Echilibrare pe teren<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/ro\/glossary\/residual-unbalance\/\">Dezechilibru rezidual<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/ro\/glossary\/balance-quality\/\">Clasele de calitate a echilibr\u0103rii<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/ro\/glossary\/dynamic-balancing\/\">Echilibrarea dinamic\u0103<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Diagnostica\u021bi mai \u00eent\u00e2i &mdash; apoi echilibra\u021bi cu \u00eencredere<\/h2>\n<p>Balanset-1A v\u0103 ofer\u0103 un analizor FFT cu dou\u0103 canale \u0219i un dispozitiv de echilibrare pe dou\u0103 planuri \u00eentr-un singur kit portabil. Citi\u021bi defectul din spectru, corecta\u021bi-l la surs\u0103 \u0219i verifica\u021bi conform ISO 20816 &mdash; totul \u00eentr-o singur\u0103 vizit\u0103 la fa\u021ba locului pentru 1.975 \u20ac.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/ro\/balanset-1a\/\">Vizualiza\u021bi Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/ro\/community\/\">Adresa\u021bi o \u00eentrebare pe forum<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Vibration Analyzer Vibration Analyzer &mdash; Two-Channel FFT Spectrum, Phase &amp; Fault Diagnostics The Balanset-1A is a two-channel vibration analyzer that plots real-time FFT spectra, measures amplitude and phase at 1&times; RPM, and maps fault signatures to distinguish unbalance, misalignment, looseness and bearing damage &mdash; then balances in [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101581","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/pages\/101581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/comments?post=101581"}],"version-history":[{"count":6,"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/pages\/101581\/revisions"}],"predecessor-version":[{"id":102102,"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/pages\/101581\/revisions\/102102"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/ro\/wp-json\/wp\/v2\/media?parent=101581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}