{"id":2186,"date":"2023-04-07T23:11:40","date_gmt":"2023-04-07T23:11:40","guid":{"rendered":"https:\/\/vibromera.eu\/?p=2186"},"modified":"2026-05-24T01:07:59","modified_gmt":"2026-05-24T01:07:59","slug":"pouzivanie-nasho-zariadenia-ako-meracieho-a-vypoctoveho-systemu-vo-vyvazenych-strojoch-vo-vnutri","status":"publish","type":"post","link":"https:\/\/vibromera.eu\/sk\/example\/using-our-equipment-as-a-measurement-and-computing-system-in-balancing-machines-video-inside\/","title":{"rendered":"Pou\u017eitie Balanset-1A ako meracieho a v\u00fdpo\u010dtov\u00e9ho syst\u00e9mu vo vyva\u017eovac\u00edch strojoch. Video vn\u00fatri"},"content":{"rendered":"<h1>Pou\u017eitie Balanset-1A ako meracieho a v\u00fdpo\u010dtov\u00e9ho syst\u00e9mu vo vyva\u017eovac\u00edch strojoch<\/h1>\n<h2>Rozsah pou\u017e\u00edvania v stacion\u00e1rnych merac\u00edch syst\u00e9moch<\/h2>\n<p>\u0160tatistiky o \u0161trukt\u00fare spotreby <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vyvazovanie\/\">vyva\u017eovanie<\/a> Z \u00fadajov o zariadeniach vyr\u00e1ban\u00fdch spolo\u010dnos\u0165ou Vibromera vypl\u00fdva, \u017ee pribli\u017ene 30 % t\u00fdchto zariaden\u00ed sa nakupuje pre stacion\u00e1rne meracie a v\u00fdpo\u010dtov\u00e9 syst\u00e9my v <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/balancing-machine\/\">vyva\u017eovacie stroje<\/a> or stands.<\/p>\n<h2>Z\u00e1klady kon\u0161trukcie strojov na m\u00e4kk\u00fdch podper\u00e1ch<\/h2>\n<p>Na kon\u0161truk\u010dnej ilustr\u00e1cii je zn\u00e1zornen\u00fd pohybliv\u00fd r\u00e1m upevnen\u00fd k pevn\u00fdm podstavcom pomocou p\u00e1skov\u00fdch pru\u017e\u00edn. Pod vplyvom odstredivej sily vyvolanej <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/rotor\/\">rotor&#8217;s<\/a> <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/unbalance\/\">nerovnov\u00e1ha<\/a>, m\u00f4\u017ee voz\u00edk vykazova\u0165 horizont\u00e1lne kmitanie vo vz\u0165ahu k pevnej podstavci. Tieto kmity sa meraj\u00fa pomocou <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vibration\/\">vibr\u00e1cie<\/a> sensor.<\/p>\n<p><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-512x1024.webp\" alt=\"Pou\u017eitie Balanset-1A ako meracieho a v\u00fdpo\u010dtov\u00e9ho syst\u00e9mu vo vyva\u017eovac\u00edch strojoch\" width=\"512\" height=\"1024\" class=\"size-large wp-image-2187\" style=\"color: initial\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-512x1024.webp 512w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-600x1200.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-150x300.webp 150w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-768x1536.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517.webp 800w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/p>\n\n<p>Using the <a href=\"https:\/\/vibromera.eu\/sk\/produkt\/balanset-1\/\">Balanset-1A<\/a> ako merac\u00ed a v\u00fdpo\u010dtov\u00fd syst\u00e9m vo vyva\u017eovac\u00edch strojoch.<\/p>\n\n<h2>K\u013e\u00fa\u010dov\u00e9 vlastnosti strojov Softbearing<\/h2>\n<p>Kon\u0161trukcia nosn\u00e9ho syst\u00e9mu dosahuje n\u00edzku vlastn\u00fa frekvenciu kmitania voz\u00edka v rozmedz\u00ed 1 - 2 Hz. To umo\u017e\u0148uje vyv\u00e1\u017eenie rotora v \u0161irokom frekven\u010dnom rozsahu od 200 ot\u00e1\u010dok za min\u00fatu. V\u010faka relat\u00edvnej jednoduchosti v\u00fdroby tak\u00fdchto podpier je t\u00e1to kon\u0161trukcia ve\u013emi atrakt\u00edvna pre na\u0161ich z\u00e1kazn\u00edkov, ktor\u00ed si \u010dasto stavaj\u00fa vlastn\u00e9 \u0161pecializovan\u00e9 vyva\u017eovacie stroje.<\/p>\n<h2>Parametre, ktor\u00e9 treba zoh\u013eadni\u0165 pri n\u00e1vrhu podpory<\/h2>\n<p>Jedn\u00fdm z najd\u00f4le\u017eitej\u0161\u00edch parametrov, ktor\u00e9 je potrebn\u00e9 zoh\u013eadni\u0165 pri navrhovan\u00ed a v\u00fdrobe t\u00fdchto podper, je ich <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/natural-frequency\/\">vlastn\u00e9 kmito\u010dty<\/a>. Tieto frekvencie s\u00fa k\u013e\u00fa\u010dov\u00e9 pre presn\u00e9 meranie vibr\u00e1ci\u00ed <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/amplitude\/\">amplit\u00fada<\/a> a <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/phase\/\">f\u00e1za<\/a>. V pr\u00edpadoch, ke\u010f sa vlastn\u00e1 rezonan\u010dn\u00e1 frekvencia podpery zhoduje s ot\u00e1\u010dkovou frekvenciou rotora (<a href=\"https:\/\/vibromera.eu\/sk\/glossary\/resonance\/\">rezonancia<\/a>), s\u00fa presn\u00e9 merania prakticky nemo\u017en\u00e9.<\/p>\n<h2>D\u00f4sledky rezonancie<\/h2>\n<p>Po\u010das vyva\u017eovania ak\u00e9hoko\u013evek mechanizmu v rezonan\u010dnej z\u00f3ne m\u00f4\u017eu aj mal\u00e9 zmeny frekvencie vies\u0165 k v\u00fdraznej nestabilite v\u00fdsledkov merania. To ovplyv\u0148uje presnos\u0165 parametrov korek\u010dnej hmotnosti a v kone\u010dnom d\u00f4sledku zni\u017euje kvalitu vyva\u017eovania. V pr\u00edpade strojov s m\u00e4kk\u00fdmi lo\u017eiskami by doln\u00e1 hranica pr\u00edpustn\u00fdch pracovn\u00fdch frekvenci\u00ed vyva\u017eovan\u00e9ho rotora mala prekro\u010di\u0165 vlastn\u00fa frekvenciu kmitania podpery aspo\u0148 2 a\u017e 3-kr\u00e1t.<\/p>\n<p>Cie\u013eom tohto \u010dl\u00e1nku je objasni\u0165 pokro\u010dil\u00e9 aplik\u00e1cie a kritick\u00e9 parametre, ktor\u00e9 je potrebn\u00e9 zoh\u013eadni\u0165 pri pou\u017e\u00edvan\u00ed zariaden\u00ed Vibromera vo vyva\u017eovac\u00edch strojoch s m\u00e4kk\u00fdmi lo\u017eiskami.<\/p>\n<div id=\"attachment_2188\" style=\"width: 522px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2188\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-512x1024.webp\" alt=\"Pou\u017eitie Balanset-1A ako meracieho a v\u00fdpo\u010dtov\u00e9ho syst\u00e9mu vo vyva\u017eovac\u00edch strojoch\" width=\"512\" height=\"1024\" class=\"size-large wp-image-2188\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-512x1024.webp 512w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-600x1200.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-150x300.webp 150w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-768x1536.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535.webp 800w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><p id=\"caption-attachment-2188\" class=\"wp-caption-text\">Pou\u017eitie Balanset-1A ako meracieho a v\u00fdpo\u010dtov\u00e9ho syst\u00e9mu vo vyva\u017eovac\u00edch strojoch<\/p><\/div>\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Pou\u017eitie Balanset-1A ako meracieho a v\u00fdpo\u010dtov\u00e9ho syst\u00e9mu vo vyva\u017eovac\u00edch strojoch\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/Kt-NHg-QhXY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>","protected":false},"excerpt":{"rendered":"<p>Using Balanset-1A as a measurement and computing system in balancing machines Extent of Usage in Stationary Measurement Systems Statistics on the consumption structure of balancing devices manufactured by Vibromera reveal that approximately 30% of these devices are purchased for stationary measurement and computational systems in balancing machines or stands. Softbearing [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2188,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ai_generated_summary":"","footnotes":""},"categories":[4,9],"tags":[],"class_list":["post-2186","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-example","category-rotors"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts\/2186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/comments?post=2186"}],"version-history":[{"count":1,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts\/2186\/revisions"}],"predecessor-version":[{"id":101512,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts\/2186\/revisions\/101512"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/media\/2188"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/media?parent=2186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/categories?post=2186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/tags?post=2186"}],"curies":[{"name":"pracovn\u00fd list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}