{"id":2234,"date":"2023-04-09T14:58:59","date_gmt":"2023-04-09T14:58:59","guid":{"rendered":"https:\/\/vibromera.eu\/?p=2234"},"modified":"2026-05-24T01:08:42","modified_gmt":"2026-05-24T01:08:42","slug":"prenosny-vibrometer-vyvazovacka-vyvazenie","status":"publish","type":"post","link":"https:\/\/vibromera.eu\/sk\/example\/portable-vibrometer-balancer-arbalance\/","title":{"rendered":"Prenosn\u00fd vibra\u010dn\u00fd vyva\u017eova\u010d ArBalance."},"content":{"rendered":"<h1>Prenosn\u00fd vibr\u00f3metr \u2013 zariadenie na vyva\u017eovanie ArBalance<\/h1>\n<p>Po\u010das vyva\u017eovania lesn\u00edckeho mul\u010dova\u010da Fecon s nadstavcom FAE n\u00e1\u0161 \u0161pecialista zaznamenal kr\u00e1tke vide\u00e1, ktor\u00e9 ukazuj\u00fa <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/rotor\/\">rotor<\/a> <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vyvazovanie\/\">vyva\u017eovanie<\/a> process.<\/p>\n<h2>ArBalance a Balanset-1A: zdie\u013ean\u00e1 platforma<\/h2>\n<p>V tejto uk\u00e1\u017eke bol pou\u017eit\u00fd prenosn\u00fd <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vibration-analyzer\/\">analyz\u00e1tor vibr\u00e1ci\u00ed<\/a> ArBalance. Postup sa riadi rovnak\u00fdm princ\u00edpom ako vyva\u017eovanie pomocou zariadenia <a href=\"https:\/\/vibromera.eu\/sk\/produkt\/balanset-1\/\">Balanset-1A<\/a> . Oba syst\u00e9my pou\u017e\u00edvaj\u00fa identick\u00e9 sn\u00edma\u010de vibr\u00e1ci\u00ed a <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/laser-tachometer\/\">laserov\u00fd tachometer<\/a>, a ich technick\u00e9 vlastnosti s\u00fa takmer rovnak\u00e9. V pr\u00edpade potreby m\u00f4\u017ee ArBalance fungova\u0165 aj ako samostatn\u00e9 <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vibration-monitoring\/\">meranie vibr\u00e1ci\u00ed<\/a> syst\u00e9m pre priemyseln\u00e9 stroje.<\/p>\n<p><iframe loading=\"lazy\" title=\"Proces vyva\u017eovania mul\u010dova\u010da pomocou ArBalance alebo Balanset-1A\" width=\"563\" height=\"1000\" src=\"https:\/\/www.youtube.com\/embed\/eoeCEnBO4fs?feature=oembed&#038;enablejsapi=1&#038;origin=https:\/\/vibromera.eu\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<h2>Plne auton\u00f3mny ter\u00e9nny pr\u00edstroj<\/h2>\n<p>Na rozdiel od syst\u00e9mov pripojen\u00fdch k PC je ArBalance plne auton\u00f3mny. Nevy\u017eaduje notebook ani extern\u00fd zdroj nap\u00e1jania. Zabudovan\u00e1 bat\u00e9ria umo\u017e\u0148uje nepretr\u017eit\u00fa prev\u00e1dzku pribli\u017ene 10\u201312 hod\u00edn, \u010do je v\u00fdhodn\u00e9 pri <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vyvazovanie-pola\/\">vyva\u017eovanie na mieste<\/a> a meran\u00ed vibr\u00e1ci\u00ed v od\u013eahl\u00fdch oblastiach.<\/p>\n<h2>Diagnostick\u00e9 schopnosti<\/h2>\n<p>Zariadenie poskytuje grafy vibr\u00e1ci\u00ed, <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/time-waveform\/\">priebeh sign\u00e1lu v \u010dasovej oblasti<\/a>, and full <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/spectral-analysis\/\">spektr\u00e1lna anal\u00fdza<\/a>. Tieto funkcie pom\u00e1haj\u00fa pos\u00fadi\u0165 technick\u00fd stav stroja, odhali\u0165 <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/unbalance\/\">nevyv\u00e1\u017eenos\u0165<\/a>, <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/misalignment\/\">nespr\u00e1vne zarovnanie<\/a>, alebo <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/resonance\/\">rezonancia<\/a>, a identifikova\u0165 hlavn\u00e9 pr\u00ed\u010diny por\u00fach.<\/p>\n<p>ArBalance obsahuje dva nez\u00e1visl\u00e9 vibra\u010dn\u00e9 kan\u00e1ly, \u010do umo\u017e\u0148uje meranie vibr\u00e1ci\u00ed v <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/two-plane-balancing\/\">dve roviny<\/a> naraz. T\u00fdm sa zvy\u0161uje presnos\u0165 a efekt\u00edvnos\u0165 <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/dynamic-balancing\/\">dynamick\u00e9 vyva\u017eovanie rotora<\/a> v porovnan\u00ed s jednokan\u00e1lov\u00fdmi syst\u00e9mami.<\/p>\n<p>Vstavan\u00fd algoritmus spracovania sign\u00e1lu zabezpe\u010duje stabiln\u00e9 od\u010d\u00edtavanie vibr\u00e1ci\u00ed <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/amplitude\/\">amplit\u00fada<\/a> a <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/phase\/\">f\u00e1za<\/a>, a to aj pri pr\u00edtomnosti poza\u010fov\u00fdch vibr\u00e1ci\u00ed alebo elektrick\u00e9ho \u0161umu.<\/p>\n<p>V\u010faka tomu je vibra\u010dn\u00fd analyz\u00e1tor ArBalance spo\u013eahliv\u00fdm a univerz\u00e1lnym n\u00e1strojom na vyva\u017eovanie na mieste, <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/vibration-analysis\/\">anal\u00fdza vibr\u00e1ci\u00ed<\/a>a spektr\u00e1lnu diagnostiku rota\u010dn\u00fdch zariaden\u00ed.<\/p>\n<h2>Main features<\/h2>\n<ul>\n<li>Meran\u00ed vibr\u00e1ci\u00ed s dvojit\u00fdm kan\u00e1lom<\/li>\n<li>Vibr\u00e1cie <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/velocity\/\">r\u00fdchlos\u0165<\/a> meranie a\u017e do 80 mm\/s <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/rms\/\">RMS<\/a><\/li>\n<li><a href=\"https:\/\/vibromera.eu\/sk\/glossary\/frequency\/\">Frekvencia<\/a> rozsah 5\u20131000 Hz<\/li>\n<li><a href=\"https:\/\/vibromera.eu\/sk\/glossary\/fft\/\">R\u00fdchla premena funkcie (FFT)<\/a> spektr\u00e1lna anal\u00fdza a grafy vibr\u00e1ci\u00ed<\/li>\n<li><a href=\"https:\/\/vibromera.eu\/sk\/glossary\/phase-angle\/\">F\u00e1zov\u00fd uhol<\/a> measurement 0\u2013360\u00b0 (\u00b11\u00b0 accuracy)<\/li>\n<li>Built-in <a href=\"https:\/\/vibromera.eu\/sk\/glossary\/tachometer\/\">tachometer<\/a> input<\/li>\n<li>\u2013 Dlh\u00e1 v\u00fddr\u017e nab\u00edjate\u013enej bat\u00e9rie (10\u201312 hod\u00edn prev\u00e1dzky)<\/li>\n<\/ul>\n<p>Tak\u00e1to kombin\u00e1cia funkci\u00ed umo\u017e\u0148uje \u0161pecialistom vykon\u00e1va\u0165 kompletn\u00fa vibra\u010dn\u00fa anal\u00fdzu a vyva\u017eovanie v ter\u00e9ne \u2013 bez pripojenia k extern\u00fdm po\u010d\u00edta\u010dom alebo zdrojom nap\u00e1jania.<\/p>\n<div id=\"attachment_1877\" style=\"width: 756px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1877\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1.webp\" alt=\"Prenosn\u00fd analyz\u00e1tor vibr\u00e1ci\u00ed ArBalance\" width=\"746\" height=\"496\" class=\"size-full wp-image-1877\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1.webp 746w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-230x153.webp 230w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-600x399.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-300x199.webp 300w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-360x240.webp 360w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal2s-1-272x182.webp 272w\" sizes=\"auto, (max-width: 746px) 100vw, 746px\" \/><p id=\"caption-attachment-1877\" class=\"wp-caption-text\">Prenosn\u00fd analyz\u00e1tor vibr\u00e1ci\u00ed ArBalance<\/p><\/div>\n<div id=\"attachment_1879\" style=\"width: 329px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1879\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal3ssw1-1.webp\" alt=\"Analyz\u00e1tor vibr\u00e1ci\u00ed ArBalance\" width=\"319\" height=\"386\" class=\"size-full wp-image-1879\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal3ssw1-1.webp 319w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal3ssw1-1-248x300.webp 248w\" sizes=\"auto, (max-width: 319px) 100vw, 319px\" \/><p id=\"caption-attachment-1879\" class=\"wp-caption-text\">Analyz\u00e1tor vibr\u00e1ci\u00ed ArBalance<\/p><\/div>\n<div id=\"attachment_1878\" style=\"width: 330px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1878\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal4ssw-1.webp\" alt=\"Vibra\u010dn\u00e9 grafy a spektr\u00e1lna anal\u00fdza\" width=\"320\" height=\"445\" class=\"size-large wp-image-1878\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal4ssw-1.webp 320w, https:\/\/vibromera.eu\/wp-content\/uploads\/2022\/12\/Arbal4ssw-1-216x300.webp 216w\" sizes=\"auto, (max-width: 320px) 100vw, 320px\" \/><p id=\"caption-attachment-1878\" class=\"wp-caption-text\">Vibra\u010dn\u00e9 grafy a spektr\u00e1lna anal\u00fdza<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>Portable vibrometer balancer ArBalance During the balancing of the Fecon forestry mulcher with the FAE attachment, our specialist recorded short videos showing the rotor balancing process. ArBalance and the Balanset-1A: A Shared Platform In this demonstration, a portable vibration analyzer ArBalance was used. The procedure follows the same principle as [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1877,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ai_generated_summary":"","footnotes":""},"categories":[4,54],"tags":[],"class_list":["post-2234","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-example","category-content"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts\/2234","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/comments?post=2234"}],"version-history":[{"count":3,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts\/2234\/revisions"}],"predecessor-version":[{"id":101517,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/posts\/2234\/revisions\/101517"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/media\/1877"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/media?parent=2234"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/categories?post=2234"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vibromera.eu\/sk\/wp-json\/wp\/v2\/tags?post=2234"}],"curies":[{"name":"pracovn\u00fd list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}