{"id":101571,"date":"2026-05-30T21:40:59","date_gmt":"2026-05-30T21:40:59","guid":{"rendered":"https:\/\/vibromera.eu\/?page_id=101571"},"modified":"2026-07-02T18:41:59","modified_gmt":"2026-07-02T18:41:59","slug":"axial-fans","status":"publish","type":"page","link":"https:\/\/vibromera.eu\/sl\/balancing-catalog\/axial-fans\/","title":{"rendered":"Izravnava aksialnega ventilatorja"},"content":{"rendered":"<div class=\"vbm-cat\">\n<style>\n.vbm-cat .vbm-answer{background:#eaf1ec;border-left:4px solid #2f6e46;border-radius:4px;padding:16px 20px;margin:0 0 24px;font-size:16px;line-height:1.65;color:#16202b}\n.vbm-cat .vbm-toc{display:flex;flex-wrap:wrap;gap:8px;margin:0 0 32px;padding:0}\n.vbm-cat .vbm-toc a{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:999px;padding:5.6px 13.6px;font-size:13.6px;color:#1f3a5f;text-decoration:none;white-space:nowrap;transition:background .18s,color .18s}\n.vbm-cat .vbm-toc a:hover{background:#1f3a5f;color:#fff}\n.vbm-cat .vbm-kit{display:grid;grid-template-columns:1fr 1fr;gap:32px;align-items:start;margin:24px 0}\n@media(max-width:700px){.vbm-cat .vbm-kit{grid-template-columns:1fr}}\n.vbm-cat .vbm-kit .media{margin:0}\n.vbm-cat .vbm-kit .media img{width:100%;border-radius:6px;display:block}\n.vbm-cat .vbm-kit .price{font-size:21.6px;font-weight:700;color:#b9542d;margin:8px 0 16px}\n.vbm-cat .vbm-kit .price span{font-size:13.6px;font-weight:400;color:#555}\n.vbm-cat ul.vbm-kit-list{list-style:none;margin:8px 0 20px;padding:0}\n.vbm-cat ul.vbm-kit-list li{padding:4.8px 0 4.8px 25.6px;position:relative;font-size:15.2px}\n.vbm-cat ul.vbm-kit-list li::before{content:\"\u2713\";position:absolute;left:0;color:#2f6e46;font-weight:700}\n.vbm-cat .vbm-variants{display:grid;grid-template-columns:1fr 1fr;gap:20px;margin:24px 0}\n@media(max-width:600px){.vbm-cat .vbm-variants{grid-template-columns:1fr}}\n.vbm-cat .vbm-variant{border:2px solid #cbd5e1;border-radius:8px;padding:17.6px 20px}\n.vbm-cat .vbm-variant.is-primary{border-color:#b9542d;background:#faf4ef}\n.vbm-cat .vbm-variant .tag{display:inline-block;font-size:11.52px;font-weight:700;text-transform:uppercase;letter-spacing:.06em;background:#b9542d;color:#fff;border-radius:3px;padding:.15em .55em;margin-bottom:8px}\n.vbm-cat .vbm-variant:not(.is-primary) .tag{background:#1f3a5f}\n.vbm-cat .vbm-variant h3{margin:4.8px 0 8px;font-size:16.8px}\n.vbm-cat .vbm-variant p{margin:0;font-size:14.4px;color:#444}\n.vbm-cat table.vbm-table{width:100%;border-collapse:collapse;margin:20px 0;font-size:14.4px}\n.vbm-cat table.vbm-table caption{text-align:left;font-weight:700;margin-bottom:6.4px;color:#1f3a5f}\n.vbm-cat table.vbm-table th{background:#1f3a5f;color:#fff;padding:8.8px 12px;text-align:left}\n.vbm-cat table.vbm-table td{padding:8px 12px;border-bottom:1px solid #e2e8f0;vertical-align:top}\n.vbm-cat table.vbm-table tr:nth-child(even) td{background:#f8fafc}\n.vbm-cat table.vbm-table td.yes{color:#2f6e46;font-weight:700}\n.vbm-cat table.vbm-table td.no{color:#a32a22;font-weight:700}\n.vbm-cat .vbm-trust{display:flex;flex-wrap:wrap;gap:9.6px;margin-top:20px}\n.vbm-cat .vbm-trust span{background:#f1f5f9;border:1px solid #cbd5e1;border-radius:4px;padding:4.8px 12px;font-size:13.44px;color:#333}\n<\/style>\n<p class=\"vbm-cat-bc\"><a href=\"https:\/\/vibromera.eu\/sl\/balancing-catalog\/\">Storitve uravnote\u017eenja<\/a> \u203a <a href=\"https:\/\/vibromera.eu\/sl\/balancing-catalog\/fans\/\">Ventilatorji<\/a> ' Osni ventilatorji<\/p>\n<div class=\"vbm-hero2\">\n<div>\n<h1>Uravnote\u017eenje aksialnih ventilatorjev &mdash; na kraju samem, pri obratovalni hitrosti<\/h1>\n<p class=\"lede\">Pri lopaticah, ceveh in velikih ventilatorjih z aksialnim tokom pride do vibracij, ko erozija lopatic, nabiranje umazanije ali popravilo spremenijo njihovo razporeditev mase. Uravnote\u017eimo rotorje aksialnih ventilatorjev <strong>na kraju samem, pri obratovalni hitrosti<\/strong> - brez odstranitve iz kanala in brez demonta\u017ee rotorja - z enim samim obiskom na kraju samem odpravite glavni vzrok za okvaro le\u017eaja, drgnjenje konic lopatic in strukturno utrujenost.<\/p>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/sl\/balanset-1a\/\">Pridobite napravo Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/sl\/community\/\">Vpra\u0161ajte na\u0161ega in\u017eenirja<\/a>\n<\/div>\n<\/div>\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2017\/12\/20131113_130218-768x1024.webp\" alt=\"Uravnote\u017eenje rotorja aksialnega ventilatorja na kraju samem pri obratovalni hitrosti v kanalu\" loading=\"lazy\"><\/figure>\n<\/div>\n<p class=\"vbm-answer\"><b>Na kratko:<\/b> Uravnote\u017eenje aksialnih ventilatorjev se izvaja na kraju samem, ko rotor pri normalni obratovalni hitrosti deluje v kanalu, z uporabo metode vplivnega koeficienta. Merilnik pospe\u0161ka vibracij na ohi\u0161ju le\u017eaja in laserski tahometer na gredi merita stanje neuravnote\u017eenosti; naprava Balanset-1A izra\u010duna natan\u010dno korekcijsko maso in kotni polo\u017eaj. Brez odstranitve rotorja, brez transporta &mdash; tipi\u010dno opravilo je kon\u010dano v manj kot eni uri, vibracije se zmanj\u0161ajo za 70&nbsp;% ali ve\u010d, dose\u017eeni so razredi uravnote\u017eenosti ISO&nbsp;14694 \/ ISO&nbsp;21940-11, \u017eivljenjska doba le\u017eajev pa se podalj\u0161a za osemkrat ali ve\u010d.<\/p>\n<nav class=\"vbm-toc\">\n<a href=\"#signs\">Simptomi<\/a><br \/>\n<a href=\"#why\">Vzroki in stro\u0161ki<\/a><br \/>\n<a href=\"#how\">Korak za korakom<\/a><br \/>\n<a href=\"#what\">Kaj uravnote\u017eimo<\/a><br \/>\n<a href=\"#standards\">Standardi<\/a><br \/>\n<a href=\"#device\">Balanset-1A<\/a><br \/>\n<a href=\"#compare\">Polje proti stroju<\/a><br \/>\n<a href=\"#cases\">Pravi primeri<\/a><br \/>\n<a href=\"#calc\">Kalkulatorji<\/a><br \/>\n<a href=\"#faq\">POGOSTA VPRA\u0160ANJA<\/a><br \/>\n<\/nav>\n<div class=\"vbm-sec\" id=\"signs\">\n<h2>Znaki, da je va\u0161 aksialni ventilator neuravnote\u017een<\/h2>\n<p>Neuravnote\u017eenost aksialnega ventilatorja se poka\u017ee z zna\u010dilnim nizom simptomov, ki se ob neupo\u0161tevanju postopoma slab\u0161ajo:<\/p>\n<div class=\"vbm-signs\">\n<div><b>Mo\u010dne vibracije 1\u00d7 RPM<\/b> Prevladujo\u010da komponenta v spektru vibracij, ki se pojavi enkrat na obrat, je najjasnej\u0161i pokazatelj neravnovesja mase rotorja - to takoj potrdi zaslon FFT naprave Balanset-1A.<\/div>\n<div><b>Pulziranje zra\u010dnega toka v kanalih<\/b> Neuravnote\u017een obro\u010d lopatic ustvarja asimetri\u010dno vle\u010dno silo, kar povzro\u010da nihanje tlaka, ki valovi po povezanih kanalih in se \u010duti kot ritmi\u010dno brnenje.<\/div>\n<div><b>Hitra okvara le\u017eaja<\/b> Rotacijske centrifugalne obremenitve zaradi neuravnote\u017eenosti se nalagajo na aerodinami\u010dne obremenitve in zmanj\u0161ujejo L<sub>10<\/sub> \u017eivljenjsko dobo na manj\u0161i del nazivne vrednosti.<\/div>\n<div><b>Drgnjenje konice rezila<\/b> Stranski odklon gredi zaradi neuravnote\u017eenosti pribli\u017ea konice rezil obro\u010du oklepa, kar povzro\u010di prekinjen stik, hrup in po\u0161kodbe rezil.<\/div>\n<div><b>Razrahljanje temeljnega vijaka<\/b> Cikli\u010dno tresenje utruja navoje in protivibracijske nosilce, zaradi \u010desar se pritrdilni elementi med obi\u010dajnim delovanjem lahko umaknejo.<\/div>\n<div><b>Pove\u010dan tok motorja<\/b> Mehanske vibracije se vra\u010dajo kot spremenljiva obremenitev pogonskega motorja, kar pove\u010duje porabo toka, porabo energije in temperaturo motorja.<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"why\">\n<h2>Zakaj aksialni ventilatorji izgubijo ravnote\u017eje - in koliko to stane<\/h2>\n<p>Aksialni ventilator zapusti tovarno z ravnote\u017enimi tolerancami, vendar se to ravnovesje hitro poru\u0161i pri uporabi na terenu. Abrazivni delci v zra\u010dnem toku neenakomerno erodirajo sprednje robove lopatic; prah in vlaknasti material se kopi\u010dita na tla\u010dni strani nekaterih lopatic, medtem ko druge ostanejo \u010diste; korozija asimetri\u010dno po\u0161koduje zadnje robove; zamenjave lopatic ali popravila zvarov pa dodajo lokalno maso na eni strani pesta. Ker je centrifugalna sila sorazmerna z <em>kvadrat<\/em> hitrosti vrtenja, \u017ee premik 20 g na konici lopatice ustvari ve\u010d sto njutonskih dinami\u010dnih sil pri obi\u010dajnih hitrostih ventilatorja - veliko ve\u010d, kot je bil zasnovan za prevzem dodatne radialne obremenitve v le\u017eaju.<\/p>\n<p>Finan\u010dne posledice se hitro kopi\u010dijo: zamenjava le\u017eajev in labirintnih tesnil, delo v sili med nena\u010drtovanimi zaustavitvami, zmanj\u0161ana u\u010dinkovitost ventilatorja zaradi sprememb zra\u010dnosti lopatic in morebitna strukturna utrujenost nosilne jeklene konstrukcije. Z enim samim postopkom uravnote\u017eenja na kraju samem - obi\u010dajno traja manj kot eno uro - se dinami\u010dna sila odpravi pri izvoru, namesto da bi se vedno znova odpravljali simptomi, ki se pojavljajo v nadaljevanju.<\/p>\n<\/div>\n<div class=\"vbm-band\">\n<div class=\"vbm-stats\">\n<div class=\"vbm-stat\"><b>\u00d710<\/b><span>\u017eivljenjska doba le\u017eaja pri prepolovitvi vibracij<\/span><\/div>\n<div class=\"vbm-stat\"><b>&minus;70%<\/b><span>tipi\u010den padec vibracij po eni seansi<\/span><\/div>\n<div class=\"vbm-stat\"><b>2<\/b><span>ravnini popravljeni v enem obisku<\/span><\/div>\n<div class=\"vbm-stat\"><b>&lt;1h<\/b><span>tipi\u010dno delo na delovnem mestu<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Zakaj prepolovitev vibracij pove\u010da \u017eivljenjsko dobo le\u017eaja<\/h2>\n<div class=\"vbm-callout\"><b>ISO 281<\/b> opredeljuje nazivno \u017eivljenjsko dobo kotalnega le\u017eaja kot <b>L<sub>10<\/sub> = (C\/P)<sup>p<\/sup><\/b>, kjer je P dinami\u010dna obremenitev, ki jo prena\u0161a le\u017eaj, in eksponent p = 3 za krogli\u010dne in 10\/3 za valj\u010dne le\u017eaje. Preostala neuravnote\u017eenost <em>je<\/em> da se vrtilna radialna obremenitev P in amplituda vibracij neposredno sledita tej obremenitvi - zato se z zmanj\u0161anjem vibracij na polovico prepolovi P in \u017eivljenjska doba le\u017eaja pove\u010da za 2<sup>p<\/sup>: pribli\u017eno <b>8\u00d7 za krogli\u010dne le\u017eaje in ~10\u00d7 za valj\u010dne le\u017eaje<\/b> (2<sup>10\/3<\/sup>&nbsp;&asymp;&nbsp;10). Izra\u010dunajte svoje vrednosti v na\u0161em <a href=\"https:\/\/vibromera.eu\/sl\/calculators\/bearing-load\/\">kalkulator \u017eivljenjske dobe le\u017eaja<\/a>.<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"how\">\n<h2>Kako uravnote\u017eimo aksialni ventilator - korak za korakom<\/h2>\n<p>Uravnote\u017eenje na terenu z napravo Balanset-1A poteka po metodi vplivnega koeficienta &mdash; po istem sistemati\u010dnem postopku, ki ga lahko izvedete sami na kraju samem, brez predhodnega poznavanja geometrije rotorja:<\/p>\n<ol class=\"vbm-steps\">\n<li><b>Namestite senzorje.<\/b> Na ohi\u0161je le\u017eaja ventilatorja je pritrjen merilnik pospe\u0161ka vibracij, laserski tahometer pa je usmerjen na odsevni trak na gredi ali pesto. Ventilator ves \u010das deluje pod normalnimi pogoji delovanja - demonta\u017ea ni potrebna.<\/li>\n<li><b>Izmerite izhodi\u0161\u010dno vrednost.<\/b> Z enim zagonom pri polni delovni hitrosti se zabele\u017eita amplituda vibracij in fazni kot pri 1\u00d7 vrtljajih na minuto, s \u010dimer se ugotovita velikost in smer trenutnega stanja neuravnote\u017eenosti.<\/li>\n<li><b>Dodajte poskusno ute\u017e.<\/b> Majhna preskusna masa z znano maso se pritrdi na obro\u010d rezila, disk pesta ali koren rezila v zabele\u017eenem kotnem polo\u017eaju. Drugi preskus poka\u017ee, kako se rotor odziva na dolo\u010deno maso na tem mestu - koeficient vpliva.<\/li>\n<li><b>Naj naprava izra\u010duna.<\/b> Balanset-1A uporablja algoritem koeficienta vpliva za izra\u010dun natan\u010dne korekcijske mase in kotne razporeditve - enoplo\u0161\u010dno za ozke rotorje, dvoplo\u0161\u010dno za \u0161iroke obro\u010de lopatic, velike tunelske ventilatorje ali konfiguracije s pesto in konico, kjer je neuravnote\u017eenost razporejena vzdol\u017e osi rotorja.<\/li>\n<li><b>Namestite korekcijsko ute\u017e.<\/b> Izra\u010dunano maso privarite, privija\u010dite ali vpnite na ozna\u010denem mestu na kolutu pesta, korenu rezila ali obro\u010du za uravnote\u017eenje. Poskusna ute\u017e se odstrani, razen \u010de je del re\u0161itve.<\/li>\n<li><b>Preverite in dokumentirajte.<\/b> Zadnja meritev potrdi, da je preostala neuravnote\u017eenost znotraj toleran\u010dnega pasu ISO za razred uravnote\u017eenosti ventilatorja. Balanset-1A ustvari poro\u010dilo o uravnote\u017eenju za evidence o vzdr\u017eevanju in dokumentacijo o skladnosti.<\/li>\n<\/ol>\n<\/div>\n<div class=\"vbm-sec\" id=\"what\">\n<h2>Kaj uravnote\u017eimo<\/h2>\n<ul class=\"vbm-list\">\n<li>Ventilatorji z lopaticami (kanalski, z vodilnimi lopaticami)<\/li>\n<li>Cevno-osni ventilatorji (propeler v valjastem ohi\u0161ju)<\/li>\n<li>Veliki aksialni ventilatorji (prezra\u010devanje rudnikov, predori)<\/li>\n<li>Ventilatorji za kotle s prisilnim (FD) in induciranim (ID) vlekom<\/li>\n<li>Ventilatorji propelerja hladilnega stolpa<\/li>\n<li>Stre\u0161ni ventilatorji za odsesavanje<\/li>\n<li>Aksialni ventilatorji za odvod dima in po\u017earno odporni ventilatorji<\/li>\n<li>Reverzibilni aksialni ventilatorji z lopaticami s spremenljivim naklonom<\/li>\n<li>Ventilatorji za su\u0161enje kmetijskega \u017eita<\/li>\n<li>Majhni aksialni ventilatorji, vgrajeni v kanale<\/li>\n<\/ul>\n<\/div>\n<div class=\"vbm-sec\" id=\"standards\">\n<h2>Tolerance in standardi<\/h2>\n<div class=\"vbm-callout\">\n<p><b>ISO 14694<\/b> dolo\u010da mejne vrednosti kakovosti ravnote\u017eja in vibracij za industrijske ventilatorje ter opredeljuje dovoljeno preostalo neuravnote\u017eenost po kategorijah uporabe ventilatorjev (BV-1 do BV-5). Osnovne tolerance kakovosti ravnote\u017eja so opredeljene v <b>ISO 21940-11<\/b> (naslednik standarda ISO 1940-1). Ve\u010dina industrijskih aksialnih ventilatorjev spada v kategorije, v katerih <b>G6.3<\/b> je najni\u017eji sprejemljivi razred; ventilatorji, ki uporabljajo kriti\u010dni procesni zrak, vnetljive hlape ali delujejo pri visokih hitrostih vrtenja, morajo obi\u010dajno ustrezati <b>G2.5 ali bolj\u0161i<\/b>.<\/p>\n<p>Izravnavamo do stopnje, ki jo zahteva va\u0161a kategorija ventilatorjev, in za va\u0161e evidence o vzdr\u017eevanju in skladnosti zagotavljamo dokumentirane podatke o preostalem neravnovesju - v g-mm pri izmerjeni obratovalni hitrosti. Uporabite na\u0161e <a href=\"https:\/\/vibromera.eu\/sl\/calculators\/residual-unbalance-iso1940\/\">kalkulator preostalih neravnovesij<\/a> da pred za\u010detkom ugotovite dopustno toleranco.<\/p>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"device\">\n<h2>Balanset-1A &mdash; va\u0161 popolni komplet za uravnote\u017eenje na terenu<\/h2>\n<p>Vse na tej strani je narejeno z enim samim prenosnim instrumentom: <a href=\"https:\/\/vibromera.eu\/sl\/balanset-1a\/\">Balanset-1A<\/a>. Gre za dvokanalno napravo za dinami\u010dno uravnote\u017eenje in analizator vibracij, ki uravnote\u017ei rotorje aksialnih ventilatorjev <strong>v lastnih le\u017eajih, pri obratovalni hitrosti, znotraj kanala<\/strong>, z uporabo metode 3-kratnega koeficienta vpliva - programska oprema izra\u010duna natan\u010dno korekcijsko maso in kot ter shrani poro\u010dilo.<\/p>\n<div class=\"vbm-kit\">\n<figure class=\"media\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2021\/11\/%D0%91%D0%B0%D0%BB%D0%BA%D0%BE%D0%BC%D0%9A%D0%B8%D1%82-scaled-1024x683.jpg\" alt=\"Celoten komplet za uravnote\u017eenje Balanset-1A s senzorji, laserskim tahometrom, tehtnico in kov\u010dkom\" loading=\"lazy\"><\/figure>\n<div>\n<h3>Kaj je v celotnem kompletu<\/h3>\n<p class=\"price\">\u20ac1,975 <span>&middot; Celoten komplet, na zalogi, ra\u010dun za DDV<\/span><\/p>\n<ul class=\"vbm-kit-list\">\n<li>Merilna enota vmesnika (USB, 2 kanala)<\/li>\n<li>Dva vibracijska pospe\u0161kometra (4 m kabla, 10 m po izbiri)<\/li>\n<li>Laserski tahometer \/ opti\u010dni senzor faze (50-500 mm)<\/li>\n<li>Magnetno stojalo za senzor<\/li>\n<li>Digitalna tehtnica za poskusne in korekcijske ute\u017ei<\/li>\n<li>Programska oprema za uravnote\u017eenje in analizo v operacijskem sistemu Windows<\/li>\n<li>Plasti\u010dni transportni kov\u010dek<\/li>\n<\/ul>\n<div class=\"vbm-cta-row\" style=\"justify-content:flex-start\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/sl\/balanset-1a\/\">Oglejte si Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/sl\/community\/\">Vpra\u0161ajte na\u0161ega in\u017eenirja<\/a>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vbm-variants\">\n<div class=\"vbm-variant is-primary\"><span class=\"tag\">Priporo\u010deno<\/span><\/p>\n<h3>Celoten komplet<\/h3>\n<p>Enota &middot; 2 senzorja &middot; laserski tahometer &middot; magnetno stojalo &middot; digitalna tehtnica &middot; programska oprema &middot; transportni kov\u010dek. Vse, kar potrebujete za za\u010detek uravnote\u017eenja takoj po odprtju kompleta.<\/p>\n<\/div>\n<div class=\"vbm-variant\"><span class=\"tag\">OEM<\/span><\/p>\n<h3>Komplet OEM<\/h3>\n<p>Enota &middot; 2 senzorja &middot; laserski tahometer &middot; programska oprema. Za integratorje, ki \u017ee imajo stojalo, tehtnico in kov\u010dek ali ki enoto vgradijo v uravnote\u017eilni stroj.<\/p>\n<\/div>\n<\/div>\n<table class=\"vbm-table\">\n<caption>Klju\u010dne tehni\u010dne specifikacije<\/caption>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Vrednost<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Merilni kanali<\/td>\n<td>2 (uravnote\u017eenje v eni in dveh ravninah)<\/td>\n<\/tr>\n<tr>\n<td>Obmo\u010dje hitrosti vibracij<\/td>\n<td>0.2&ndash;80 mm\/s RMS<\/td>\n<\/tr>\n<tr>\n<td>Frekven\u010dno obmo\u010dje<\/td>\n<td>5&ndash;1000 Hz (&le;10% napaka amplitude nad 550&nbsp;Hz)<\/td>\n<\/tr>\n<tr>\n<td>Natan\u010dnost meritev<\/td>\n<td>&plusmn;5% od polnega merilnega obmo\u010dja<\/td>\n<\/tr>\n<tr>\n<td>Metoda<\/td>\n<td>3-preizkusna metoda koeficienta vpliva (1 ali 2 ravnini)<\/td>\n<\/tr>\n<tr>\n<td>Analiza<\/td>\n<td>Amplituda in faza pri 1\u00d7, FFT spekter in valovna oblika, shranjena poro\u010dila<\/td>\n<\/tr>\n<tr>\n<td>Prenosnik<\/td>\n<td>Ni vklju\u010deno (ra\u010dunalnik z operacijskim sistemom Windows, na voljo na zahtevo)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"vbm-trust\"><span><b>&#10003;<\/b> Na zalogi<\/span><span><b>&#10003;<\/b> DHL Portugalska 35 \u20ac<\/span><span><b>&#10003;<\/b> DHL po vsem svetu 110 \u20ac<\/span><span><b>&#10003;<\/b> 2-letna garancija<\/span><span><b>&#10003;<\/b> Ra\u010dun za DDV<\/span><span><b>&#10003;<\/b> In\u017eenirska podpora<\/span><\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"compare\">\n<h2>Uravnote\u017eenje na terenu v primerjavi z uravnote\u017eilnim strojem &mdash; kaj je primerno za va\u0161 ventilator?<\/h2>\n<table class=\"vbm-table\">\n<caption>Primerjava: izravnava na kraju samem v primerjavi z namenskim strojem za izravnavo<\/caption>\n<thead>\n<tr>\n<th>Faktor<\/th>\n<th>Uravnote\u017eenje polja (Balanset-1A)<\/th>\n<th>Balansirni stroj (delavnica)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ventilator odstranjen iz kanala?<\/td>\n<td class=\"yes\">Ne - te\u010de na mestu<\/td>\n<td class=\"no\">Da - potrebna je popolna demonta\u017ea<\/td>\n<\/tr>\n<tr>\n<td>Demonta\u017ea rotorja?<\/td>\n<td class=\"yes\">Ne<\/td>\n<td class=\"no\">Da<\/td>\n<\/tr>\n<tr>\n<td>Izpad proizvodnje<\/td>\n<td>Samo namestitev senzorja (&lt;15 min)<\/td>\n<td>Od ur do dni (demonta\u017ea, prevoz, uravnote\u017eenje, ponovna namestitev)<\/td>\n<\/tr>\n<tr>\n<td>Hitrost uravnote\u017eenja<\/td>\n<td>Dejanska delovna hitrost in pretok zraka<\/td>\n<td>Lo\u010deno vreteno z nizko hitrostjo<\/td>\n<\/tr>\n<tr>\n<td>Ra\u010duni za upogibanje gredi in spojke<\/td>\n<td class=\"yes\">Da - celoten sestav je uravnote\u017een na mestu samem<\/td>\n<td class=\"no\">Samo rotor, brez u\u010dinka na namestitev<\/td>\n<\/tr>\n<tr>\n<td>Lopatice s spremenljivim naklonom<\/td>\n<td class=\"yes\">Uravnote\u017eeno pri izbranem delovnem naklonu<\/td>\n<td class=\"no\">Samo s fiksnim naklonom<\/td>\n<\/tr>\n<tr>\n<td>Izpolnjeni standardi<\/td>\n<td>ISO 14694, ISO 21940-11<\/td>\n<td>ISO 21940-11<\/td>\n<\/tr>\n<tr>\n<td>Stro\u0161ki opreme<\/td>\n<td>1.975 EUR (celoten komplet)<\/td>\n<td>\u20ac10,000 - \u20ac50,000+<\/td>\n<\/tr>\n<tr>\n<td>Obi\u010dajni \u010das dela<\/td>\n<td>&lt;1 ura na lokaciji<\/td>\n<td>Skupaj 1-3 dni<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Uravnote\u017eenje na terenu je najprimernej\u0161a izbira, kadar ventilator lahko obratuje in rotor izpolnjuje merilo togega rotorja (obratovalna hitrost je precej pod prvo kriti\u010dno hitrostjo). Delavni\u0161ki stroj za uravnote\u017eenje ostaja primeren za novozgrajene rotorje brez obratovalnega \u010dasa ali za zelo velike rotorje, ki jih je treba v celoti razstaviti zaradi pregleda ali zamenjave lopatic.<\/p>\n<\/div>\n<div class=\"vbm-sec\" id=\"cases\">\n<h2>Pravi primeri uravnote\u017eenja aksialnih ventilatorjev<\/h2>\n<div class=\"vbm-cases\">\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/sl\/primer\/ventilatorji-izravnava\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2017\/12\/20131113_130218-768x1024.webp\" alt=\"Izravnava polja ventilatorskega rotorja z valj\u010dno-osno in cevnoosno metodo z Balansetom-1A\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Aksialni ventilatorji in ventilatorji z lopaticami<\/h3>\n<p>Uravnote\u017eenje rotorjev aksialnih in lopati\u010dno-aksialnih ventilatorjev na terenu v industrijskih okoljih z dokumentiranimi rezultati preostale neuravnote\u017eenosti.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/sl\/primer\/uravnotezenje-ventilatorja-izpusnih-plinov\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2017\/12\/IMG_20170828_140450-1024x576.webp\" alt=\"Izpu\u0161ni aksialni ventilator, uravnote\u017een na mestu pri obratovalni hitrosti\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Izpu\u0161ni ventilator na mestu<\/h3>\n<p>Enoravninsko uravnote\u017eenje izpu\u0161nega ventilatorja na kraju samem pri obratovalni hitrosti z napravo Balanset-1A; vibracije zmanj\u0161ane za ve\u010d kot 75&nbsp;%.<\/p>\n<\/div>\n<p><\/a><br \/>\n<a class=\"vbm-case\" href=\"https:\/\/vibromera.eu\/sl\/primer\/uravnotezenje-ventilatorjev-z-vijaki-2\/\"><img decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2018\/03\/IMG_20171228_131923-1024x768.webp\" alt=\"Postopek uravnote\u017eenja rotorja aksialnega ventilatorja HVAC korak za korakom\" loading=\"lazy\"><\/p>\n<div class=\"body\">\n<h3>Ventilator HVAC vodnik po korakih<\/h3>\n<p>Celoten postopek uravnote\u017eenja dveh ravnin za rotorje z aksialnim ventilatorjem HVAC z navodili za namestitev senzorja in pritrditev ute\u017ei.<\/p>\n<\/div>\n<p><\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec\" id=\"calc\">\n<h2>Brezpla\u010dni kalkulatorji aksialnih ventilatorjev<\/h2>\n<div class=\"vbm-chips\">\n<a href=\"https:\/\/vibromera.eu\/sl\/calculators\/blade-pass-frequency\/\">Frekvenca prehoda lopatic<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/calculators\/fan-blade-centrifugal-force\/\">Centrifugalna sila lopatice ventilatorja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/calculators\/fan-shaft-power\/\">Mo\u010d gredi ventilatorja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/calculators\/residual-unbalance-iso1940\/\">Preostala neuravnote\u017eenost (ISO 1940)<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/calculators\/trial-weight-calculator\/\">Kalkulator poskusne te\u017ee<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/calculators\/bearing-load\/\">Kalkulator \u017eivljenjske dobe le\u017eaja<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-sec vbm-faq\" id=\"faq\">\n<h2>Pogosta vpra\u0161anja o uravnote\u017eenju aksialnega ventilatorja<\/h2>\n<details>\n<summary>Ali je mogo\u010de osni ventilator uravnote\u017eiti, ne da bi ga odstranili iz kanala?<\/summary>\n<div class=\"ans\">Da &mdash; to je natanko namen uravnote\u017eenja na terenu (in-situ). Rotor ostane v lastnih le\u017eajih znotraj kanala in se uravnote\u017ei pri dejanski obratovalni hitrosti ter pretoku zraka. Demonta\u017ea, transport in lo\u010deno delavni\u0161ko uravnote\u017eenje niso potrebni, zato je zastoj minimalen in ni nevarnosti, da bi se po ponovni monta\u017ei znova pojavila neporavnanost vgradnje.<\/div>\n<\/details>\n<details>\n<summary>Kako ugotoviti, ali so vibracije posledica neuravnote\u017eenosti in ne druge napake?<\/summary>\n<div class=\"ans\">Neuravnote\u017eenost povzro\u010da prevladujo\u010do komponento vibracij pri natanko 1\u00d7 delovni frekvenci (1\u00d7 vrtljaji na minuto). \u010ce je najmo\u010dnej\u0161i vrh v spektru pri 1\u00d7 in se njegov fazni kot vrti sinhrono z gredjo, je verjeten vzrok neuravnote\u017eenost. Druge napake - okvare le\u017eajev, neskladnost, resonanca lopatic - povzro\u010dajo druga\u010dne frekven\u010dne vzorce. Naprava Balanset-1A prika\u017ee amplitudo in fazo pri 1\u00d7 ter celoten spekter FFT, kar vam pomaga potrditi diagnozo, preden dodate korekcijsko ute\u017e.<\/div>\n<\/details>\n<details>\n<summary>Ali je treba aksialne ventilatorje s spremenljivim naklonom posebej obravnavati?<\/summary>\n<div class=\"ans\">Postopek uravnote\u017eenja koeficienta vpliva je enak, vendar ga je treba izvesti pri najpogostej\u0161em delovnem kotu nagiba, saj premikanje lopatic premakne njihovo masno sredi\u0161\u010de glede na pesto. \u010ce ventilator redno deluje v \u0161irokem razponu naklona, je prakti\u010den pristop uravnote\u017eenje pri srednjem naklonu in preverjanje vibracij pri skrajnih naklonih. Postopek ponovite, \u010de se nastavitev naklona med prenovo bistveno spremeni.<\/div>\n<\/details>\n<details>\n<summary>Kateri razred ravnote\u017eja ISO velja za aksialne ventilatorje?<\/summary>\n<div class=\"ans\">Standard ISO 14694 razvr\u0161\u010da ventilatorje po kategorijah uporabe (BV-1 do BV-5). Ve\u010dina industrijskih aksialnih ventilatorjev mora ustrezati najmanj standardu G6.3; ventilatorji za uporabo v \u010distem zraku, procesih ali po\u017earno odpornih aplikacijah obi\u010dajno zahtevajo standard G2.5 ali bolj\u0161i. Balanset-1A izra\u010duna dose\u017eeno preostalo neuravnote\u017eenost v g-mm in jo primerja z mejno vrednostjo razreda ISO 21940-11 za maso in hitrost rotorja, nato pa podatek shrani v poro\u010dilo, ki ga je mogo\u010de natisniti.<\/div>\n<\/details>\n<details>\n<summary>Ena ravnina ali dve za aksialni ventilator?<\/summary>\n<div class=\"ans\">Ventilatorji z ozkimi vijaki in majhni kanalski ventilatorji z majhno osno globino glede na premer se obi\u010dajno popravijo v eni ravnini. \u0160iroki obro\u010di lopatic, tunelski ventilatorji z velikim premerom in rotorji, pri katerih so lopatice razporejene po precej\u0161nji osni dol\u017eini, potrebujejo uravnote\u017eenje v dveh ravninah (dinami\u010dno), ker se neuravnote\u017eenost porazdeli vzdol\u017e osi rotorja. Naprava Balanset-1A obvladuje oba na\u010dina z enako strojno opremo - \u0161tevilo ravnin za korekcijo izberete v programski opremi pred osnovnim zagonom.<\/div>\n<\/details>\n<details>\n<summary>Ali lahko z napravo Balanset-1A uravnote\u017eimo sami?<\/summary>\n<div class=\"ans\">Da. Balanset-1A je zasnovan tako, da ga lahko vzdr\u017eevalci uporabljajo brez posebnega usposabljanja. Programska oprema vas vodi skozi vsako meritev na zaslonu, samodejno izra\u010duna korekcijsko maso in kot ter izpi\u0161e poro\u010dilo o rezultatih. \u010ce naletite na nenavadno konfiguracijo rotorja ali \u017eelite preveriti svoj pristop, preden namestite korekcijsko maso, je na voljo na\u0161 forum skupnosti.<\/div>\n<\/details>\n<\/div>\n<div class=\"vbm-sec\">\n<h2>Spoznajte teorijo<\/h2>\n<div class=\"vbm-chips blue\">\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/axial-fan-defects\/\">Okvare aksialnega ventilatorja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/fan-defects\/\">Okvare ventilatorja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/blade-resonance\/\">Resonanca rezila<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/izravnava-polja\/\">Uravnote\u017eenje na terenu<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/balance-quality\/\">Ocene kakovosti uravnote\u017eenja<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/residual-unbalance\/\">Preostala neuravnote\u017eenost<\/a><br \/>\n<a href=\"https:\/\/vibromera.eu\/sl\/glossary\/dynamic-balancing\/\">Dinami\u010dno uravnote\u017eenje<\/a>\n<\/div>\n<\/div>\n<div class=\"vbm-band\">\n<h2>Uravnote\u017eite svoj aksialni ventilator na mestu - \u0161e danes<\/h2>\n<p>Balanset-1A vas vodi pri uravnote\u017eenju eno- in dvoplo\u0161\u010dnega aksialnega ventilatorja pri teko\u010di hitrosti znotraj kanala, izra\u010duna natan\u010dno korekcijsko te\u017eo in kot ter dokumentira dose\u017eeno preostalo neuravnote\u017eenost v skladu z ISO 14694 in ISO 21940-11. Brez odstranitve rotorja, brez izgube proizvodnje - le ti\u0161ji ventilator z dalj\u0161o \u017eivljenjsko dobo.<\/p>\n<div class=\"vbm-cta-row\">\n<a class=\"vbm-btn vbm-btn-primary\" href=\"https:\/\/vibromera.eu\/sl\/balanset-1a\/\">Oglejte si Balanset-1A<\/a><br \/>\n<a class=\"vbm-btn vbm-btn-ghost\" href=\"https:\/\/vibromera.eu\/sl\/community\/\">Postavite vpra\u0161anje na forumu<\/a>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Balancing services &rsaquo; Fans &rsaquo; Axial Fans Axial Fan Balancing &mdash; In-Situ, at Operating Speed Vane-axial, tube-axial and large axial-flow fans develop vibration the moment blade erosion, dirt build-up or a repair shifts their mass distribution. We balance axial fan rotors in situ, at running speed &mdash; no removal from [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":101558,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ai_generated_summary":"","footnotes":""},"class_list":["post-101571","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/pages\/101571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/comments?post=101571"}],"version-history":[{"count":4,"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/pages\/101571\/revisions"}],"predecessor-version":[{"id":102059,"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/pages\/101571\/revisions\/102059"}],"up":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/pages\/101558"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/sl\/wp-json\/wp\/v2\/media?parent=101571"}],"curies":[{"name":"delovni list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}