{"id":2186,"date":"2023-04-07T23:11:40","date_gmt":"2023-04-07T23:11:40","guid":{"rendered":"https:\/\/vibromera.eu\/?p=2186"},"modified":"2026-05-24T01:07:59","modified_gmt":"2026-05-24T01:07:59","slug":"using-our-equipment-as-a-measurement-and-computing-system-in-balancing-machines-video-inside","status":"publish","type":"post","link":"https:\/\/vibromera.eu\/uz\/example\/using-our-equipment-as-a-measurement-and-computing-system-in-balancing-machines-video-inside\/","title":{"rendered":"Using Balanset-1A as a measurement and computing system in balancing machines. Video inside"},"content":{"rendered":"<h1>Using Balanset-1A as a measurement and computing system in balancing machines<\/h1>\n<h2>Statsionar o&#039;lchov tizimlarida foydalanish ko&#039;lami<\/h2>\n<p>Statistics on the consumption structure of <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/balancing\/\">muvozanatlash<\/a> devices manufactured by Vibromera reveal that approximately 30% of these devices are purchased for stationary measurement and computational systems in <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/balancing-machine\/\">balanslashtirish mashinalari<\/a> or stands.<\/p>\n<h2>Yumshoq rulmanli mashinani loyihalashning asosiy qoidalari<\/h2>\n<p>\u041a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u043e\u043d \u0440\u0430\u0441\u043c \u043c\u043e\u0431\u0438\u043b \u0440\u0430\u043c\u0430\u043d\u0438 \u049b\u045e\u0440\u0493\u043e\u049b \u0441\u043e\u0434\u0434\u0430\u043b\u0430\u0440\u0433\u0430 \u0442\u0443\u0431\u0431\u0430\u043b\u0430\u0448 \u043f\u0440\u0443\u0436\u0438\u043d\u0430\u043b\u0430\u0440\u0438\u0434\u0430\u043d \u0444\u043e\u0439\u0434\u0430\u043b\u0430\u043d\u0438\u0431 \u043e\u043b\u0438\u043d\u0433\u0430\u043d \u0442\u0443\u0440\u0430\u0434\u0438. \u041c\u0430\u0440\u043a\u0430\u0437\u0438\u0439 \u043a\u0443\u0447\u0438 \u0442\u0430\u044a\u0441\u0438\u0440\u0438\u0434\u0430 \u044f\u0440\u0430\u0442\u0438\u043b\u0433\u0430\u043d <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/rotor\/\">rotor&#8217;s<\/a> <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/unbalance\/\">imbalance<\/a>\u0430\u0440\u0432\u043e\u049b \u0441\u043e\u0434\u0434\u0430\u0433\u0430 \u043d\u0438\u0441\u0431\u0430\u0442\u0430\u043d \u0433\u043e\u0440\u0438\u0437\u043e\u043d\u0442\u0430\u043b \u0442\u043e\u043b\u049b\u0438\u043d\u0438\u043c\u043d\u0438\u043d\u0433 \u044e\u049b\u043e\u0440\u0438 \u0448\u0438\u0434\u0434\u0430\u043d\u043b\u0438\u0433\u0438\u0434\u0430\u043d \u0443\u0437\u043e\u049b\u0434\u0430 \u0434\u0430\u0432\u043e\u043b \u049b\u0438\u043b\u0438\u043d\u0430\u0434\u0438. \u0411\u0443 \u0442\u043e\u043b\u049b\u0438\u043d\u0438\u043c\u043d\u0438\u043d\u0433 \u044e\u049b\u043e\u0440\u0438 \u0448\u0438\u0434\u0434\u0430\u043d\u043b\u0438\u0433\u0438 \u045e\u043b\u0447\u0430\u043d\u0430\u0434\u0438 <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/vibration\/\">vibration<\/a> sensor.<\/p>\n<p><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-512x1024.webp\" alt=\"Using Balanset-1A as a measurement and computing system in balancing machines\" width=\"512\" height=\"1024\" class=\"size-large wp-image-2187\" style=\"color: initial\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-512x1024.webp 512w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-600x1200.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-150x300.webp 150w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517-768x1536.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926517.webp 800w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/p>\n\n<p>Using the <a href=\"https:\/\/vibromera.eu\/uz\/mahsulot\/balanset-1\/\">Balanset-1A<\/a> \u0431\u0430\u043b\u0430\u043d\u0441\u0438\u0440\u043e\u0432\u043a\u0430 \u043c\u0430\u0448\u0438\u043d\u0430\u0441\u0438\u0434\u0430 \u045e\u043b\u0447\u0430\u0448 \u0432\u0430 \u0445\u0438\u0441\u043e\u0431\u043b\u0430\u0448 \u0441\u0438\u0441\u0442\u0435\u043c\u0430\u0441\u0438 \u0441\u0438\u0444\u0430\u0442\u0438\u0434\u0430.<\/p>\n\n<h2>Yumshoq rulmanli mashinalarning asosiy xususiyatlari<\/h2>\n<p>Qo&#039;llab-quvvatlash tizimining dizayni 1-2 Gts oralig&#039;ida bo&#039;lgan trolley tebranishlari uchun past tabiiy chastotaga erishadi. Bu 200 RPM dan boshlab keng chastota diapazonida rotorni muvozanatlash imkonini beradi. Bunday tayanchlarni ishlab chiqarishning nisbatan qulayligi ushbu dizaynni ko&#039;pincha o&#039;zlarining ixtisoslashtirilgan balanslash mashinalarini ishlab chiqaradigan mijozlarimiz uchun juda jozibali qiladi.<\/p>\n<h2>Qo&#039;llab-quvvatlash dizaynida e&#039;tiborga olinadigan parametrlar<\/h2>\n<p>\u0411\u0443 \u049b\u045e\u043b\u043b\u0430\u0431-\u049b\u0443\u0432\u0432\u0430\u0442\u043b\u0430\u0448\u043d\u0438\u043d\u0433 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u0441\u0438 \u0432\u0430 \u0438\u0448\u043b\u0430\u0431 \u0447\u0438\u049b\u0430\u0440\u0438\u0448\u0434\u0430 \u045e\u0439\u043b\u0430\u043d\u0438\u0448\u0438 \u043a\u0435\u0440\u0430\u043a \u0431\u045e\u043b\u0433\u0430\u043d \u045e\u0447\u0430 \u043a\u0440\u0438\u0442\u0438\u043a \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u043b\u0430\u0440\u0438\u0434\u0430\u043d \u0431\u0438\u0440\u0438 \u0443\u043b\u0430\u0440\u043d\u0438\u043d\u0433 <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/natural-frequency\/\">\u0442\u0430\u0431\u0438\u0438\u0439 \u0442\u0435\u0431\u0440\u0430\u043d\u0438\u0448 \u0447\u0430\u0441\u0442\u043e\u0442\u0430\u0441\u0438<\/a>. \u0411\u0443 \u0447\u0430\u0441\u0442\u043e\u0442\u0430\u0441\u0438 \u0442\u043e\u043b\u049b\u0438\u043d\u0438\u043c\u043d\u0438\u043d\u0433 \u044e\u049b\u043e\u0440\u0438 \u0448\u0438\u0434\u0434\u0430\u043d\u043b\u0438\u0433\u0438\u043d\u0433 \u0434\u0443\u0440\u0443\u0441\u0442 \u045e\u043b\u0447\u0430\u0431 \u043e\u043b\u0438\u0448\u0438\u0434\u0430 \u0436\u0443\u0434\u0430 \u043c\u0443\u0445\u0438\u043c <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/amplitude\/\">amplitude<\/a> and <a href=\"https:\/\/vibromera.eu\/uz\/glossary\/phase\/\">phase<\/a>. \u049a\u045e\u043b\u043b\u0430\u0431-\u049b\u0443\u0432\u0432\u0430\u0442\u043b\u0430\u0448\u043d\u0438\u043d\u0433 \u0442\u0430\u0431\u0438\u0438\u0439 \u0442\u0435\u0431\u0440\u0430\u043d\u0438\u0448 \u0447\u0430\u0441\u0442\u043e\u0442\u0430\u0441\u0438 \u0440\u043e\u0442\u043e\u0440 \u0430\u0439\u043b\u0430\u043d\u0438\u0448 \u0447\u0430\u0441\u0442\u043e\u0442\u0430\u0441\u0438 (<a href=\"https:\/\/vibromera.eu\/uz\/glossary\/resonance\/\">resonance<\/a>) \u0431\u0438\u043b\u0430\u043d \u0431\u0438\u0440 \u0445\u0438\u043b \u0431\u045e\u043b\u0433\u0430\u043d \u0445\u043e\u043b\u0430\u0442\u0438\u0434\u0430 \u0434\u0443\u0440\u0443\u0441\u0442 \u045e\u043b\u0447\u0430\u0431 \u043e\u043b\u0438\u0448 \u0434\u0435\u044f\u0440\u043b\u0438 \u0438\u043c\u043a\u043e\u043d\u0447\u0438 \u0435\u043c\u0430\u0441.<\/p>\n<h2>Rezonansning oqibatlari<\/h2>\n<p>Rezonans zonasida har qanday mexanizmni muvozanatlash paytida, hatto kichik chastotali o&#039;zgarishlar ham o&#039;lchov natijalarida sezilarli beqarorlikka olib kelishi mumkin. Bu tuzatuvchi vazn parametrlarining to&#039;g&#039;riligiga ta&#039;sir qiladi va oxir-oqibat balanslash sifatini buzadi. Yumshoq rulmanli mashinalar uchun muvozanatli rotor uchun ruxsat etilgan ish chastotalarining pastki chegarasi qo&#039;llab-quvvatlashning tabiiy tebranish chastotasidan kamida 2-3 marta oshib ketishi kerak.<\/p>\n<p>Ushbu maqola ilg&#039;or ilovalar va yumshoq rulman balanslash mashinalarida Vibromera uskunasidan foydalanishda e&#039;tiborga olinishi kerak bo&#039;lgan muhim parametrlarni yoritishga qaratilgan.<\/p>\n<div id=\"attachment_2188\" style=\"width: 522px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-2188\" src=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-512x1024.webp\" alt=\"Using Balanset-1A as a measurement and computing system in balancing machines\" width=\"512\" height=\"1024\" class=\"size-large wp-image-2188\" srcset=\"https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-512x1024.webp 512w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-600x1200.webp 600w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-150x300.webp 150w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535-768x1536.webp 768w, https:\/\/vibromera.eu\/wp-content\/uploads\/2023\/04\/1655411926535.webp 800w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><p id=\"caption-attachment-2188\" class=\"wp-caption-text\">Using Balanset-1A as a measurement and computing system in balancing machines<\/p><\/div>\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Using Balanset-1A as a measurement and computing system in balancing machines\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/Kt-NHg-QhXY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>","protected":false},"excerpt":{"rendered":"<p>Using Balanset-1A as a measurement and computing system in balancing machines Extent of Usage in Stationary Measurement Systems Statistics on the consumption structure of balancing devices manufactured by Vibromera reveal that approximately 30% of these devices are purchased for stationary measurement and computational systems in balancing machines or stands. Softbearing [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2188,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ai_generated_summary":"","footnotes":""},"categories":[4,9],"tags":[],"class_list":["post-2186","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-example","category-rotors"],"_links":{"self":[{"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/posts\/2186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/comments?post=2186"}],"version-history":[{"count":1,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/posts\/2186\/revisions"}],"predecessor-version":[{"id":101512,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/posts\/2186\/revisions\/101512"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/media\/2188"}],"wp:attachment":[{"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/media?parent=2186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/categories?post=2186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vibromera.eu\/uz\/wp-json\/wp\/v2\/tags?post=2186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}