VIBROMERA
Solusi penyeimbangan presisi
|
www.vibromera.eu Balanset-1A v2.3.17.0 (firmware ver.5.5.2 2ch)
|
1. Informasi umum
| ID rotor: HIL · P1 + P2 · 07.09.2026 · Arc27 |
Tanggal: 07.09.2026 |
| Lokasi: Bangku uji HIL; contoh pelatihan; toleransi 50 g*mm |
Penyeimbang: Balanset-1A |
2. Standar yang diterapkan
a) ___________________________________________________________
b) ___________________________________________________________ (lainnya)
3. Hasil penyeimbangan
| No. |
Putaran |
Getaran, mm/s |
Ketidakseimbangan, g*mm |
| P1 |
P2 |
Tol. |
P1 |
P2 |
Tol. |
| 1 |
Sebelum |
5.71 |
4.19 |
|
510.69 |
382.42 |
50.00 |
| 2 |
Setelah |
0.120 |
0.200 |
21.95 |
33.27 |
Catatan:
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
Teknisi:
____________________________________________________________________
Dibuat oleh sistem penyeimbangan Balanset-1A | VIBROMERA | www.vibromera.eu