Bepul Muhandislik Vositasi #045

Podshipnik statik xavfsizlik omili kalkulyatori

Statik xavfsizlik koeffitsienti s ni hisoblang0 = C0 / P0 ISO 76 bo'yicha. Podshipningiz minimal xavfsizlik koeffitsienti talablariga javob berishini tekshiring.

ISO 76 s₀ = C₀/P₀ Xavfsizlikni Baholash
Quick presets

Results

Static Safety Factor s₀
Minimum Required s₀
Assessment
Safety Margin

Statik xavfsizlik koeffitsienti

ISO 76 ga muvofiq, statik xavfsizlik koeffitsienti asosiy statik yuk ko'rsatkichining haqiqiy statik ekvivalent yukka nisbatidan iborat:

  • C0 — asosiy statik yuk ko'rsatkichi (kN), podshipnik katalogidan
  • P0 — statik ekvivalent yuk (kN), haqiqiy radial & aksial kuchlardan hisoblanadi

Minimum s0 Tavsiyalar

ApplicationBall BearingsRolikli podshipniklar
Past shovqin / silliq ishlash≥ 2.0≥ 3.0
Oddiy jim ishlash≥ 1.0≥ 1.5
Tebranishli / zarba yuklari≥ 1.5≥ 2.0
Yuqori ishonchlilik / xavfsizlik≥ 2.0≥ 3.0
Engil yuk, qo'l bilan aylantirish≥ 0.5≥ 1.0

Amaliy Misol

Misol — 6208 chuqur egli sharli podshipnik

Given: C0 = 31.5 kN, P0 = 12 kN, normal ishlash rejimi

s0 = 31.5 / 12 = 2.63

Minimal talab: s0 ≥ 1.0 → PASS (margin +163%)

ℹ️ Tip: Ishlash davomida zarbli yuklarga duchor bo'luvchi podshipniklar uchun (masalan, jag'li maydalagichlar, vibratsiyali elaklar) dinamik xizmat muddatini hisoblashga qo'shimcha ravishda s0 ni ham tekshiring.