Ücretsiz Mühendislik Aracı #045
Rulman Statik Güvenlik Faktörü Hesaplayıcısı
Calculate s0=C0/P0 using catalog C0 and a correctly determined P0. Select the required minimum from current manufacturer guidance.
Sonuçlar
Statik Güvenlik Faktörü
ISO 76'ya göre statik güvenlik faktörü, temel statik yük kapasitesinin gerçek statik eşdeğer yüke oranıdır:
- C0 — Rulman kataloğundan alınan temel statik yük değeri (kN)
- P0 — gerçek radyal & eksenel kuvvetlerden hesaplanan statik eşdeğer yük (kN)
Selecting the required factor
ISO 76:2006 specifies static ratings/equivalent load and includes guidance for heavily loaded applications. Manufacturer tables add application distinctions. Do not collapse them into a single ball/roller threshold.
ISO 76 calculations may be unsatisfactory for truncated contact, abnormal load distribution, misalignment, preload, extra-large clearance, coatings or special surface treatments. Consult the manufacturer in those cases.
Pratik Örnek
Verildi: C0 = 31,5 kN, P0 = 12 kN, normal çalışma
s0 = 31.5 / 12 = 2.63
Compare s0=2.63 with the applicable current manufacturer guideline; this arithmetic alone does not establish PASS/FAIL.
ℹ️ Scope: Static capacity should also be checked for known peak, shock or impact loads in otherwise rotating service. Dynamic rating life does not replace the static check.
Profesyonel saha balans cihazları ve titreşim analizörleri. Rulman durumunu sahada izleyin. 50'den fazla ülkede kullanılmaktadır.