Kalkulačka frekvence průchodu lopatek

Calculate the kinematic passage frequency for a known integer blade or vane count and measured shaft speed. Frequency alone does not predict amplitude or identify a fault.

BPF / VPFKinematic FrequencyNot an ISO Limit
Rychlé předvolby

Výsledky

Frekvence průchodu lopatky (BPF)
-
BPF jako násobek otáček hřídele
-
Frekvence hřídele
-
Perioda BPF
-

Harmonické BPF

Harmonická Frekvence (Hz) Násobek (× hřídel) Perioda (ms)

Passage frequency

fBPF = Z × n / 60 = Z × fs [Hz]
fs = n / 60 [Hz]

Z is the integer number of recurring rotor elements, n is shaft speed in r/min, and fs is shaft rotational frequency. For a fixed observation point, Z equally recurring elements produce Z passages per revolution. ANSI/AMCA 301-22 gives this same fan blade-pass equation in its sound-rating method (Eq. 5.7).

Harmonické a postranní pásma

The table lists mathematical integer harmonics h·fBPF. Real spectra may contain BPF, harmonics and modulation components, but their presence and amplitude depend on rotor/stator geometry, flow, loading, sensor location, structure and acoustic response. A calculated line is a frequency marker, not a predicted spectral amplitude.

Diagnostic boundary

Do not diagnose from one line. A BPF peak, its harmonics or shaft-spaced sidebands do not uniquely prove clearance error, blade damage, fouling, resonance, recirculation or cavitation. Compare like-for-like operating points with baseline/trend data and use corroborating phase, waveform, pressure, acoustic, process and inspection evidence. Cavitation assessment also requires hydraulic operating and NPSH evidence.

Worked calculation

Six vanes at 2950 r/min

fs = 2950/60 = 49.1667 Hz

fBPF = 6 × 49.1667 = 295 Hz

Perioda = 1/295 = 3.3898 ms; 2×BPF = 590 Hz; 3×BPF = 885 Hz.

Sources and standard scope

Rozsah: steady shaft speed and one integer count of equally recurring elements. Variable speed smears or sweeps the frequency; nonuniform pitch can create additional components. This calculator is not an ISO severity or acceptance assessment.

Vibromera — Přenosné vyvažování & analýza vibrací
Profesionální přístroje pro analýzu vibrací pro diagnostiku ventilátorů a čerpadel, vyvažování v provozu a monitorování stavu. Používají se ve více než 50 zemích.
Zjistěte více

© 2024–2026 Vibromera — Inženýrské kalkulačky

Kinematic equation cross-checked to ANSI/AMCA 301-22, Eq. 5.7. Not an ISO acceptance calculator. Scientific review: July 2026.