Free Engineering Converter — #030
Anderon Band Converter
Convert compatible RMS radial velocity measurements for the L, M and H bands to Anderon values under the documented 1,800 r/min test condition.
Converted Band Values
Condition-specific conversion
Sugawara defines Anderon from radial displacement density differentiated by rotation angle, band-pass filtered, expressed as an RMS quantity and normalized by the square root of passband octaves. For 1,800 r/min and its L/M/H division from 50 to 10.8 kHz, it gives 1 Anderon ≈ 7.698 μm/s.
Measurement context
| Опсег | Sugawara frequency range at 1,800 r/min |
|---|---|
| Л | 50–300 Hz |
| M | 300–1,800 Hz |
| Х | 1,800–10,800 Hz |
Sugawara unit definition и current analyzer band documentation provide the numerical relation and bands.
ISO scope
ISO 15242-1:2015 specifies fundamentals and calibration under established conditions. ISO 15242-2:2015 covers specified radial ball bearings with cylindrical bore and outside surface; it is not a general installed-machine severity standard.
No grading: no ABEC-based thresholds, PASS/FAIL decision or overall RSS is applied. Use the exact bearing test specification and agreed acceptance limits.
Процените стање лежајева професионалним анализаторима вибрација. Анализа по фреквентним опсезима за дијагностику лежајева. Користе се у преко 50 земаља.