Free Engineering Tool
Ex Marking Decoder
Enter any IEC 60079 / ATEX Ex marking string to decode protection type, gas group, temperature class, EPL, and zone suitability.
IEC 60079ATEXZone 0/1/2
Decoded Marking
Protection Types
| Code | Method | IEC Standard | Typical Zone |
|---|---|---|---|
| d | Flameproof enclosure | IEC 60079-1 | Zone 1, 2 |
| e | Increased safety | IEC 60079-7 | Zone 1, 2 |
| ia | Intrinsic safety (level a) | IEC 60079-11 | Zone 0, 1, 2 |
| ib | Intrinsic safety (level b) | IEC 60079-11 | Zone 1, 2 |
| ic | Intrinsic safety (level c) | IEC 60079-11 | Zone 2 |
| p/px/py/pz | Pressurized enclosure | IEC 60079-2 | Zone 1, 2 |
| m/ma/mb | Encapsulation | IEC 60079-18 | Zone 0, 1, 2 |
| nA/nC/nR | Non-sparking / Type n | IEC 60079-15 | Zone 2 |
| o | Oil immersion | IEC 60079-6 | Zone 1, 2 |
| q | Powder filling | IEC 60079-5 | Zone 1, 2 |
| t/ta/tb/tc | Protection by enclosure (dust) | IEC 60079-31 | Zone 20/21/22 |
Temperature Classes
| Class | Max Surface Temp (°C) | Typical Gases |
|---|---|---|
| T1 | 450 | Hydrogen, methane, propane |
| T2 | 300 | Ethanol, butane, acetone |
| T3 | 200 | Gasoline, hydrogen sulfide, diesel |
| T4 | 135 | Acetaldehyde, diethyl ether |
| T5 | 100 | — |
| T6 | 85 | Carbon disulfide |
Vibromera — Portable Balancing & Vibration Analysis
Vibration analysis instruments suitable for hazardous areas. Professional field balancing in Ex zones.
Learn MoreVibration analysis instruments suitable for hazardous areas. Professional field balancing in Ex zones.