Orifice Plate Flow Calculator — ISO 5167
Calculate flow rate through an orifice plate per ISO 5167. Enter orifice and pipe diameters, differential pressure, and fluid density.
This calculator was developed and verified by the Vibromera engineering team, makers of the Balanset portable balancing instruments.
Results
ISO 5167 Orifice Flow Equation
- C — discharge coefficient (Reader-Harris/Gallagher equation)
- ε — expansibility factor (1.0 for incompressible liquids)
- β — diameter ratio d/D
- ΔP — differential pressure across orifice
- ρ — upstream fluid density
Simplified Discharge Coefficient
For corner taps, C ≈ 0.5959 + 0.0312β^2.1 − 0.184β⁸ (simplified Reader-Harris). For flange taps, add correction terms for pipe diameter.
⚠️ Note: This calculator uses a simplified C estimation. For custody transfer metering, use the full Reader-Harris/Gallagher equation with Reynolds number correction per ISO 5167-2.
Professional instruments. Used in 50+ countries.
Nikolai Shelkovenko
Nikolai Shelkovenko is a vibration analysis engineer and the founder and CEO of Vibromera. For more than 15 years he has balanced rotating equipment in the field rather than on a test bench: mulchers, industrial fans, crushers, centrifuges, shafts and spindles. That work is what the Balanset instruments grew out of — they were designed as a tool a specialist can carry to the machine and use alone, on site, not as laboratory equipment. Vibromera was founded in 2017 and has been based in Porto, Portugal, since 2023. Development, assembly and support of the Balanset line all happen here. The flagship instrument is the Balanset-1A, a portable analyser for single- and two-plane balancing and for vibration diagnostics. Nikolai is personally involved in customer support, in working through difficult balancing cases and in the development of the software. He works with customers worldwide, in any language.