Source-gated flow arithmetic
Documented-Coefficient Orifice Flow
Calculate flow only after C and ε have been established for the exact plate,tappings,flow regime and operating point by the controlling procedure.
Coefficient-based arithmetic
Implemented arithmetic
All quantities are converted to SI before calculation.qv is volume flow on the entered upstream-density basis;it is not standard/normal gas volume.C and ε are inputs,not results.
Current standards
ISO5167-1:2022,edition3,sets general principles,installation and uncertainty requirements.The public scope requires a full circular conduit,single-phase subsonic non-pulsating flow.ISO5167-2:2022,edition2,covers qualifying orifice plates with flange,corner,or D andD/2 tappings in conjunction with Part1;its public scope excludes D below50mm or above1000mm and pipe Reynolds number below5000.
Removed unsafe model
The previous page called `0.5959+0.0312β^2.1−0.184β^8` a simplified Reader-Harris coefficient while omitting Reynolds and tapping terms.It also accepted arbitrary ε without upstream pressure or thermodynamic inputs.That model is not retained.
Извори
ISO5167-1:2022 official record; ISO5167-2:2022 official record; ISO/TR12767:2023 official record.