Source-gated flow arithmetic

Documented-Coefficient Orifice Flow

Calculate flow only after C and ε have been established for the exact plate,tappings,flow regime and operating point by the controlling procedure.

C not inventedε not inventedNot ISO conformity

Coefficient-based arithmetic

Upstream-basis volume flow qv
Mass flow qm
Diameter ratio β
Orifice area
Entered-coefficient arithmetic only.

Implemented arithmetic

qv = [C·ε / √(1−β⁴)] · (πd²/4) · √(2Δp/ρ1); β=d/D; qm=ρ1qv

All quantities are converted to SI before calculation.qv is volume flow on the entered upstream-density basis;it is not standard/normal gas volume.C and ε are inputs,not results.

Current standards

ISO5167-1:2022,edition3,sets general principles,installation and uncertainty requirements.The public scope requires a full circular conduit,single-phase subsonic non-pulsating flow.ISO5167-2:2022,edition2,covers qualifying orifice plates with flange,corner,or D andD/2 tappings in conjunction with Part1;its public scope excludes D below50mm or above1000mm and pipe Reynolds number below5000.

Not an ISO calculator: exact C,ε,beta/Reynolds limits,tap corrections,geometry,straight lengths and uncertainty rules remain NEEDS_LICENSED_SOURCE.Passing this input gate does not establish ISO conformity,custody-transfer suitability or fitness for service.

Removed unsafe model

The previous page called `0.5959+0.0312β^2.1−0.184β^8` a simplified Reader-Harris coefficient while omitting Reynolds and tapping terms.It also accepted arbitrary ε without upstream pressure or thermodynamic inputs.That model is not retained.

Źródła

ISO5167-1:2022 official record; ISO5167-2:2022 official record; ISO/TR12767:2023 official record.