Tasuta inseneri tööriist
Toru läbimõõdu kalkulaator vooluhulgast
Arvutage toru minimaalne siseläbimõõt voolukiiruse ja kiirusepiirangu põhjal. Ümardage standardsete DN-suurusteni. Pöördrežiim: antud toru suuruse maksimaalne vooluhulk.
Tulemused
Minimaalne toru läbimõõt
Järjepidevuse võrrandist Q = v × A ja A = πd²/4:
Arvutatud läbimõõt on minimaalne; ümardage alati üles üles järgmise standardsuuruseni.
Vastupidine arvutus — maksimaalne vool
Standardsed torusuurused (Schedule 40)
| Nominaalne | Välisläbimõõt (mm) | Seina paksus (mm) | Siseläbimõõt (mm) | Pindala (mm²) |
|---|---|---|---|---|
| DN15 (½″) | 21.3 | 2.77 | 15.8 | 196 |
| DN20 (¾″) | 26.7 | 2.87 | 20.9 | 343 |
| DN25 (1″) | 33.4 | 3.38 | 26.6 | 556 |
| DN32 (1¼″) | 42.2 | 3.56 | 35.1 | 968 |
| DN40 (1½″) | 48.3 | 3.68 | 40.9 | 1,314 |
| DN50 (2″) | 60.3 | 3.91 | 52.5 | 2,165 |
| DN65 (2½″) | 73.0 | 5.16 | 62.7 | 3,087 |
| DN80 (3″) | 88.9 | 5.49 | 77.9 | 4,768 |
| DN100 (4″) | 114.3 | 6.02 | 102.3 | 8,213 |
| DN125 (5″) | 141.3 | 6.55 | 128.2 | 12,908 |
| DN150 (6″) | 168.3 | 7.11 | 154.1 | 18,638 |
| DN200 (8″) | 219.1 | 8.18 | 202.7 | 32,270 |
| DN250 (10″) | 273.1 | 9.27 | 254.5 | 50,869 |
| DN300 (12″) | 323.9 | 10.31 | 303.2 | 72,145 |
Majanduslik kiirus
majanduslik kiirus on voolukiirus, mis minimeerib kogukulu - tasakaalustades toru maksumuse (kapitalikulu) ja pumpamiskulu (energia):
- Väiksem kiirus → suurem toru (kallis), aga väiksem pumpamisvõimsus
- Suurem kiirus → väiksem toru (odavam), aga rohkem energiat pumpamiseks
- Tüüpilised ökonoomsed kiirused veele: 1–2 m/s; hüdraulikaõlile: 3–5 m/s rõhuliinides
💡 Rusikareegel: Süsteemide puhul, mis töötavad üle 4000 tunni aastas, tuleks eelistada madalamaid kiirusi. Vahelduva tööga süsteemide puhul on vastuvõetavad suuremad kiirused (väiksemad torud).
Praktiline näide
Antud: Q = 60 l/min, v_max = 4 m/s
Q = 60 / 60000 = 0,001 m³/s
d_min = √(4 × 0,001 / (π × 4)) = √ (3,183 × 10⁻⁴) = 17,84 mm
Standardsuurus: ümarda ülespoole DN20 (sisediameeter = 20,9 mm)
Tegelik kiirus: v = 0,001 / (π/4 × 0,0209²) = 2,92 m/s ✓ piires
⚠️ Märkus: Veenduge alati, et valitud standardse torusuuruse tegelik kiirus jääb teie piiridesse. Kui järgmine väiksem standardsuurus ületaks kiirusepiiri, peate kasutama suuremat suurust.
Use the formula d = √(4Q / (πv)), where Q is the flow rate in m³/s and v is the maximum allowable velocity in m/s.
Example: 60 L/min at max 4 m/s → d = √(4 × 0.001 / (π × 4)) = 17.8 mm → round up to DN20 (ID 20.9 mm).
Recommended maximum velocities:
- Hydraulic suction: 0.5 – 1.5 m/s (to avoid cavitation)
- Hydraulic pressure: 3 – 6 m/s (up to 7 for short runs)
- Hydraulic return: 2 – 4 m/s
- Water supply: 1 – 3 m/s (≤2.5 in buildings for noise)
These are economic velocities — balancing pipe cost vs pumping energy.
DN (Diamètre Nominal) sizes for Schedule 40 steel pipe:
- DN15 (½″): ID 15.8 mm
- DN25 (1″): ID 26.6 mm
- DN50 (2″): ID 52.5 mm
- DN100 (4″): ID 102.3 mm
- DN150 (6″): ID 154.1 mm
- DN200 (8″): ID 202.7 mm
Note: ID depends on the schedule (wall thickness). Schedule 40 is most common; Schedule 80 has thicker walls and smaller ID.
Economic velocity is the speed that minimizes the total lifecycle cost of a piping system — which includes both the capital cost of the pipe and the ongoing energy cost of pumping.
Larger pipes cost more to buy but have lower pressure drop → less pumping energy. Smaller pipes are cheaper but need more pumping power.
For systems running continuously (>4000 h/yr), use lower velocities. For intermittent systems, higher velocities are acceptable.
Rounding down would exceed your velocity limit, causing:
- Higher pressure drop (ΔP ∝ v²)
- Noise and vibration
- Potential cavitation on suction lines
- Increased erosion and fitting wear
Always round up. The actual velocity with the larger pipe will be lower than your limit — which is safe.
Sellel lehel kirjeldatud protseduurid töötas välja ja testis välitingimustes Vibromera meeskond, kasutades Balanset-1A-d, kaasaskantavat kahekanalilist tasakaalustusseadet ja vibratsioonianalüsaatorit rootorite tasakaalustamiseks kohapeal.
Professionaalsed välitasakaalustusseadmed ja tarkvara. Kasutusel enam kui 50 riigis.
Nikolai Shelkovenko
Nikolai Shelkovenko on vibratsioonianalüüsi insener ning Vibromera asutaja ja tegevjuht. Rohkem kui 15 aastat on ta tasakaalustanud pöörlevaid seadmeid kohapeal, mitte katsestendil: multšereid, tööstuslikke ventilaatoreid, purustajaid, tsentrifuuge, võlle ja spindleid. Just sellest tööst kasvasid välja Balanset seadmed — need kavandati tööriistana, mille spetsialist saab masina juurde kaasa võtta ja üksi kohapeal kasutada, mitte laboriseadmena. Vibromera asutati 2017. aastal ja alates 2023. aastast asub see Portos Portugalis. Siin toimub kogu Balanset seeria arendus, koostamine ja tugi. Lipulaevaks on Balanset-1A, kaasaskantav analüsaator ühe- ja kahetasapinnaliseks tasakaalustamiseks ning vibratsioonidiagnostikaks. Nikolai osaleb isiklikult klienditoes, keeruliste tasakaalustusjuhtumite lahendamises ja tarkvara arendamises. Ta töötab klientidega üle kogu maailma, mis tahes keeles.