Meet Vibromera.com — our new international website. Visit Vibromera.com →

User-supplied criteria

Traceable Vibration Limit Comparator

Compare one vibration value with warning and action limits from an identified applicable source. Optional baseline arithmetic is shown without invented ISO multipliers.

No embedded ISO tablesExplicit measurement identityInclusive limit logic

प्रयोज्यता जांच: this tool does not select a machine standard or reproduce licensed tables. Verify machine type, power/speed, support, rotating/non-rotating measurement, quantity, frequency band, location/direction and operating condition before entering limits.

Comparison with supplied limits

स्थिति
Distance to / beyond governing limit
Difference from matched baseline
गणना नहीं की गई
Ratio to matched baseline
गणना नहीं की गई
Percent change from matched baseline
गणना नहीं की गई

M<W: below warning;   W≤M<A: warning reached;   M≥A: action reached
Δ=M−B;   ratio=M/B;   change=100(M−B)/B

आईएसओ 13373-1:2002, confirmed in 2024, gives general vibration condition-monitoring procedures covering measurement methods/parameters, transducer selection/location/attachment, collection, operating conditions, signal conditioning and monitoring systems. It is not a universal numerical alarm table. आईएसओ 13373-2:2016 addresses processing, analysis and presentation of vibration data.

आईएसओ 20816-1:2016 provides general measurement/evaluation conditions and says quantities/methods must be well defined with limitations understood. Machinery-specific criteria belong in the applicable part. For example, आईएसओ 20816-3:2022 has a specific industrial-machine scope above 15 kW and 120–30000 r/min plus explicit exclusions; it cannot be applied merely from a generic “pump”, “compressor” or “small machine” label.

No diagnosis or shutdown command: reaching a supplied value triggers the action defined by its controlling source and site procedure. A scalar comparator does not identify a fault, predict imminent failure or replace competent review of spectra, phase, process data and measurement validity.

© २०२४–२०२६ वाइब्रोमेरा

Comparator for traceable supplied limits; no embedded ISO severity values. Scientific review: July 2026.