Free Engineering Converter — #030

Anderon Band Converter

Convert compatible RMS radial velocity measurements for the L, M and H bands to Anderon values under the documented 1,800 r/min test condition.

1 And ≈ 7.698 μm/s1,800 r/min ConditionISO 15242-2 Context

การประยุกต์ใช้: the factor is valid for the Sugawara-documented 1,800 r/min L/M/H condition and matching bandwidth normalization. Do not use ordinary overall machine-vibration values as if they were Anderon band measurements.

Converted Band Values

L Band
M Band
H Band
Condition-Specific Factor
1 And ≈ 7.698 μm/s

Condition-specific conversion

Anderon ≈ vband,RMS / 7.698

Sugawara defines Anderon from radial displacement density differentiated by rotation angle, band-pass filtered, expressed as an RMS quantity and normalized by the square root of passband octaves. For 1,800 r/min and its L/M/H division from 50 to 10.8 kHz, it gives 1 Anderon ≈ 7.698 μm/s.

Measurement context

ย่านSugawara frequency range at 1,800 r/min
L50–300 เฮิรตซ์
M300–1,800 Hz
H1,800–10,800 Hz

Sugawara unit definition และ current analyzer band documentation provide the numerical relation and bands.

ขอบเขต ISO

ISO 15242-1:2015 specifies fundamentals and calibration under established conditions. ISO 15242-2:2015 covers specified radial ball bearings with cylindrical bore and outside surface; it is not a general installed-machine severity standard.

No grading: no ABEC-based thresholds, PASS/FAIL decision or overall RSS is applied. Use the exact bearing test specification and agreed acceptance limits.