Free Engineering Tool — #144
এয়ার রিসিভার ট্যাংক ভলিউম ক্যালকুলেটর
Determine the required air receiver tank size based on compressor output, cut-in/cut-out pressure, and demand time.
V = Q×t×P_atm / (P_max − P_min)
Litres & Gallons
Results
Required Receiver Volume
—
Stored Energy (Free Air)
—
Pressure Band ΔP
—
Air Demand (Free Air)
—
Receiver Volume Formula
- ভি — receiver volume (litres)
- Q — air demand (L/s at atmospheric pressure)
- t — allowable pressure drop time (seconds)
- Patm — atmospheric pressure (1.013 bar abs)
- Pসর্বোচ্চ — cut-out pressure (bar gauge)
- Pmin — cut-in pressure (bar gauge)
Example — Medium Workshop
Given: Q = 15 L/s, t = 30 s, P_max = 8 bar, P_min = 6 bar
V = 15 × 30 × 1.013 / (8 − 6) = 227.9 litres
Select a standard 250 L receiver tank.
⚠️ Note: Always round up to the next standard tank size. Consider adding 10–20% margin for future expansion.