Besplatan Inženjerski Alat

Kalkulator za Dimenzionisanje i Protok CETOP Hidrauličnog Ventila

Size CETOP/ISO 4401 valves based on flow rate and pressure drop. Calculate the required flow coefficient Kv (in L/min/√bar), power loss, and recommended valve size.

ISO 4401CETOP 03–10Kv in L/min/√bar
Quick presets

Results

Preporučena CETOP veličina
Required Kv (L/min/√bar)
Gubitak snage kroz ventil
Generisanje topline
Dimenzije montaže
Port Sizes
Bolt Pattern
Brzina u otvorima

Kapacitet protoka (Kv)

Unit convention: this calculator uses the hydraulics convention with Kv in L/min/√bar — the flow in L/min of water (SG = 1) that produces a 1 bar pressure drop. The standard metric valve coefficient (VDI/VDE 2173, IEC 60534) is defined as water flow in m³/h at 1 bar, so Kv [m³/h] = 0.06 × Kv [L/min/√bar]. Always check which convention a manufacturer’s catalogue uses before comparing values. Note that ISO 4401 standardizes only the valve mounting interface — not the flow coefficient convention.

Power Loss

Referenca CETOP veličine

CETOPNGP,T PortsA,B PortsBoltsFace (mm)Typical Kv (L/min/√bar)Flow (L/min)
03NG6G3/8G3/84×M569.9×36.58–1240–80
05NG10G1/2G1/24×M6102.4×56.415–2580–120
07NG16G3/4G3/44×M8152×8030–50120–350
08NG25G1G14×M10197×10255–80350–600
10NG32G1-1/4G1-1/44×M12255×13090–120600–1000

Praktični primjer

Primer — Izaberite ventil za 80 L/min, ΔP=8 bar

Required Kv = 80 / √(8/0.87) = 80 / 3.03 = 26.4 L/min/√bar (≈ 26.4 × 0.06 = 1.6 m³/h in the standard metric Kv convention)

CETOP 05 has typical Kv = 15–25 → borderline → CETOP 07 (NG16) recommended

Power loss = 80 × 8 / 600 = 1.07 kW

Vibromera — Prenosivo Balansiranje & Analiza Vibracija
Profesionalni instrumenti. Korišćeni u 50+ zemalja.