Upoznajte Vibromera.com — našu novu međunarodnu web stranicu. Posjetite Vibromera.com →

Besplatan Inženjerski Alat

Kalkulator Koeficijenta Protoka Ventila

Dvosmjerni Kv/Cv kalkulator za dimenzionisanje ventila. Izračunajte Kv iz protoka + ΔP, protok iz Kv + ΔP, ili ΔP iz Kv + protoka. Za protok tečnosti.

Kv / Cv Tečnost Dvosmjerno Cv = 1.156 × Kv
Brze unaprijed postavljene vrijednosti

Rezultati

Koeficijent protoka Kv
—
Cv (US)
—
Protok
—
Pad pritiska
—
Preporučeni ventil Kv (×1,3)
—
Preporučeni ventil Cv (×1,3)
—

Kv za protok tekućine

Koeficijent protoka Kv (evropski standard) definisan je kao protok vode u m³/h kroz ventil pri padu tlaka od 1 bar:

  • Kv — koeficijent protoka (m³/h pri ΔP = 1 bar)
  • Q — volumetrijski protok (m³/h)
  • SG — specifična težina (voda = 1,0; hidrauličko ulje ≈ 0,87)
  • ΔP — pad tlaka kroz ventil (bar)

Konverzija Kv ↔ Cv

Cv je ekvivalent u SAD/carskom sistemu: protok u US GPM vode pri ΔP = 1 psi i 60°F.

Vodič za dimenzionisanje ventila

Tip ventilaTipičan raspon KvNapomene
Kuglasti ventil DN1510 – 40Puna otvornost preporučena za hidrauliku
Kuglasti ventil DN2550 – 200Mali pad pritiska pri punoj otvorenosti
Kuglasti ventil DN50250 – 800Najčešće korišten u procesima
Globusni ventil DN258 – 15Dobar za prigušenje/kontrolu
Globusni ventil DN5025 – 50Veći ΔP nego kuglasti ventil
Leptirasti ventil DN100300 – 600Kompaktan, veliki protoci
Iglični ventil0.1 – 5Fina regulacija protoka

Praktični primjer

Primer — Hidraulični usmeravajući ventil

Zadano: Q = 60 L/min hidrauličko ulje (SG = 0.87), ΔP = 5 bar

Pretvori: Q = 60 / 1000 × 60 = 3.6 m³/h

Kv = 3.6 × √(0.87 / 5) = 3.6 × 0.417 = 1.50

Cv = 1.50 × 1.156 = 1.74

Preporučeni ventil Kv ≥ 1.50 × 1.3 = 1.95 (sa marginom sigurnosti)

⚠️ Napomena: Za kritične primjene također provjerite: indeks kavitacije (FL faktor), nivo buke, raspon regulacije i dinamički odgovor. Konsultirajte softver proizvođača ventila za konačan odabir.

Kv is the volumetric flow of water at 15°C in m³/h that passes through a valve with a pressure drop of 1 bar. It is a measure of the valve's flow capacity — higher Kv means the valve can pass more flow for the same pressure drop.

Example: A valve with Kv = 10 passes 10 m³/h of water at 1 bar ΔP.

Kv — European/ISO standard. Flow in m³/h of water at ΔP = 1 bar.

Cv — US standard. Flow in US GPM of water at ΔP = 1 psi at 60°F.

Conversion: Cv = 1.156 × Kv (or Kv = 0.865 × Cv).

Steps for valve sizing:

  • Calculate required Kv for your worst-case operating conditions
  • Select a valve with Kv ≥ 1.3× calculated Kv (safety margin)
  • Ensure the valve operates between 20–80% open at normal flow
  • Check cavitation: ΔP should not exceed the valve's FL² × (P1 – Pv)
  • Verify noise level is acceptable

No. Gas flow is compressible, so the liquid formula underestimates the required Kv. Use the gas-specific formula that includes upstream and downstream absolute pressures, temperature, and compressibility factor Z.

For critical flow (P2 < 0.53 × P1), the flow becomes choked and the formula changes further.

Cavitation occurs when the local pressure drops below the liquid's vapor pressure, forming bubbles that collapse violently — causing noise, vibration, and valve damage.

Flashing occurs when downstream pressure stays below vapor pressure — the liquid partially vaporizes permanently.

Check the valve's FL factor (pressure recovery factor). The allowable ΔP for no cavitation is: ΔPmax = FL² × (P1 – Pv), where Pv is vapor pressure.

Procedure opisane na ovoj stranici razvio je i terenski testirao tim Vibromera koristeći Balanset-1A, prenosivi dvokanalni balanser i analizator vibracija za balansiranje rotora na licu mjesta.

Vibromera — Prenosivo Balansiranje & Analiza Vibracija
Profesionalni instrumenti i softver za balansiranje na terenu. Koristi se u 50+ zemalja.
Saznajte više o uređajima za balansiranje Vibromera
Kategorije:

Nikolai Shelkovenko

Nikolai Shelkovenko

Nikolai Shelkovenko je inženjer analize vibracija te osnivač i izvršni direktor kompanije Vibromera. Više od 15 godina balansira rotacionu opremu na terenu, a ne na ispitnom stolu: malčere, industrijske ventilatore, drobilice, centrifuge, vratila i vretena. Upravo je iz tog rada nastala serija instrumenata Balanset — osmišljeni su kao alat koji stručnjak može ponijeti do mašine i njime raditi sam, na licu mjesta, a ne kao laboratorijska oprema. Vibromera je osnovana 2017. godine, a od 2023. sjedište joj je u Portu u Portugalu. Ovdje se odvijaju razvoj, sklapanje i podrška za liniju Balanset. Vodeći instrument je Balanset-1A, prijenosni analizator za balansiranje u jednoj i dvije ravni te za vibracijsku dijagnostiku. Nikolai lično učestvuje u podršci korisnicima, u rješavanju složenih slučajeva balansiranja i u razvoju softvera. Radi s korisnicima širom svijeta, na bilo kojem jeziku.

WhatsApp
Balanset-1A · €1975Pitajte inženjera