Meet Vibromera.com — our new international website. Visit Vibromera.com →
Exact plate transcription · one rating/configuration · arithmetic consistency only

Three-Phase Induction-Motor Nameplate Consistency Worksheet

Cross-check one balanced sinusoidal three-phase induction-motor rated point. The worksheet does not claim to decode every motor plate and does not invent duty,thermal,IP,IC,IM,frame,terminal or IE meanings from a partial drop-down list.

Starts blankSame rating pair requiredCurrent IEC editionsNo automatic compliance decision

Transcribe one controlled rating

Use line-to-line RMS voltage,line RMS current,output power,power factor,frequency and speed that belong to the same connection and rating. Do not combine Δ/Y or dual-frequency rows.

Mechanical output power—not electrical input.
From the selected connection/rating row.
Same row and operating rating as ULL.
Positive even whole number from controlled evidence.
Induction-motor motoring speed below synchronous speed.
Ratio0–1 for this same sinusoidal rated state.
Leave blank unless explicitly stated for this rating.
Preserve symbols and paired values verbatim.
Decision boundary: arithmetic agreement does not prove IEC conformity or identify the correct wiring,duty,temperature rise,IP test,IE class,frame dimensions,starting capability or safe application. Resolve discrepancies against the manufacturer documentation and the licensed standards applicable to the exact machine.

Equations,units and applicability

IlośćEquationGranica
Prędkość synchronicznanₛ=120f/P obr./minRotating-field speed from frequency and even pole count.
Poślizgs=(nₛ−n)/nₛInduction motor in motoring operation;this worksheet requires0<s<1.
Shaft torqueT=Pout·1000/[2π(n/60)] N·mMean torque corresponding to the entered mechanical output and speed.
Three-phase apparent powerS=√3 ULL IL/1000 kVABalanced three-phase RMS line quantities.
Active input and efficiencyPin=λS;η=Pout/PinSame sinusoidal rating;λ is power factor,not a guessed IE-class value.

These are general electrical and mechanical relations derived from definitions. They are not a normative “IEC nameplate decoder,”not an IEC efficiency test method and not a substitute for the tolerances and test procedures in the licensed standards.

Which standard owns each marking?

FieldCurrent source routeWorksheet treatment
Rating,duty,performance,thermal limits and markingIEC60034-1:2026,Edition15;replaces2022Record verbatim;exact requirements are NEEDS_LICENSED_SOURCE.
Mains-operated efficiency/loss testIEC60034-2-1:2024,Edition3No compliance/test-method claim from plate arithmetic.
Converter-fed motor efficiency/lossIEC60034-2-3:2024,Edition2Outside this sinusoidal worksheet.
IE efficiency classIEC60034-30-1:2025,Edition2Record exact marking;class minimum is not actual η and no table is reproduced.
Motor enclosure IP codeIEC60034-5:2020,Edition5 + COR1:2024;general enclosure route IEC60529 Ed2.2Record full code and product scope;no partial menu decoding.
Cooling IC codeIEC60034-6:1991,Edition2;stability2028Record complete or simplified designation verbatim.
Construction/mounting IM codeIEC60034-7:2020,Edition3 + COR:2023Record whether Code I or Code II;no inferred mounting.
Terminal markings/rotationIEC60034-8:2026,Edition4Use the actual diagram/documentation;no automatic Δ/Y instruction.
Frame dimensionsIEC60072-1:2022,Edition7 where applicableNie parseInt(frame) shaft-height inference for arbitrary systems.
Thermal classIEC60085:2007,Edition4 plus machine requirementsNo universal ambient+rise+hotspot table without the applicable method and conditions.

Interpretation safeguards

  • Never combine voltage from one Δ/Y row with current,power factor or efficiency from another row.
  • IE1–IE5 are class limits inside a defined scope;they are not measured or guaranteed operating-point efficiency values. IEC60034-30-1:2025 replaced the2014 edition and introduced normative IE5 limits.
  • Duty types S1–S10 require the full current definitions,cycle quantities and rating context. “S1” is not simply permission for unlimited operation under any ambient,load or cooling condition.
  • An IP code states a tested enclosure protection classification inside its scope;it is not a corrosion,condensation,explosion,chemical or outdoor-suitability decision.
  • A leading frame number may correspond to shaft height only when the declared dimensional system and exact designation make that mapping applicable.
  • For distorted,unbalanced,converter-fed,multi-speed,synchronous,DC,generator or non-IEC machines,use the applicable model and standards instead of this worksheet.

Co skorygowano

The former page claimed to read any motor plate but always used a balanced three-phase formula,preselected a complete fictitious plate and accepted malformed or physically inconsistent values. It could display negative slip,efficiency above100%,NaN reactive power and unqualified “full-load” conclusions.

The former decoder echoed user-selected S/IP/IE/thermal labels as authoritative meanings,reproduced an outdated2014 IE table with an indicative IE5 value,and treated the leading digits of any frame string as shaft height. Those tables and automatic decoders were removed. The replacement requires exact evidence,checks only one explicit physical model,uses strict parsing and does not infer closed-standard content.