Motor Sizing Calculator
Calculate required motor power from load parameters and get recommended standard IEC motor size with starting current and torque estimates.
IEC Standard Sizes0.37 – 315 kWDOL / Y-Δ / VFD
Motor Selection
Recommended Standard Motor
—
Required Power (with SF)
—
Load Torque
—
Starting Current (est.)
—
Starting Torque Ratio
—
Motor Utilization
—
Motor Power Calculation
Prequired = Pload × Service Factor or P = T × n / 9550
IEC Standard Motor Sizes (kW)
| Range | Available Sizes (kW) |
|---|---|
| Small | 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3.0, 4.0 |
| Medium | 5.5, 7.5, 11, 15, 18.5, 22, 30, 37 |
| Large | 45, 55, 75, 90, 110, 132, 160, 200, 250, 315 |
Starting Current Multipliers
- DOL — 6–8× rated current
- Star-Delta — 2–3× rated (÷3 of DOL)
- Soft Starter — 2–4× rated
- VFD — 1–1.5× rated
ℹ️ Tip: Always select the next standard size above the calculated requirement. Oversizing by one step provides thermal margin and longer bearing life.