电机尺寸计算器
根据负载参数计算所需的电机功率,并获得推荐的标准IEC电机尺寸以及启动电流和扭矩估算值。
电机选择
电机功率计算
IEC标准电机尺寸(kW)
| 范围 | 可用功率(千瓦) |
|---|---|
| 小的 | 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3.0, 4.0 |
| 中等的 | 5.5, 7.5, 11, 15, 18.5, 22, 30, 37 |
| 较大 | 45, 55, 75, 90, 110, 132, 160, 200, 250, 315 |
启动电流倍数
- DOL(直接在线启动) — 额定电流的 6–8 倍
- 星三角 — 2–3倍评级(÷3 DOL)
- 软启动器 — 评级 2–4 倍
- 变频器 — 评级为 1–1.5 倍
ℹ️提示: 始终选择比计算需求大一号的标准尺寸。尺寸大一号可以提供热裕度并延长轴承寿命。
Service factor (SF) accounts for operating conditions beyond rated values. Use 1.0 for ideal conditions, 1.15 for moderate ambient or occasional overloads, 1.25 for harsh environments, and 1.5 for severe duty with frequent starts or high-inertia loads.
Constant torque loads (conveyors, positive displacement pumps) require the same torque regardless of speed — power is proportional to speed. Variable torque loads (centrifugal fans/pumps) have torque proportional to speed² and power proportional to speed³ — they need much less power at reduced speed.
Motors are only made in standard sizes. You must always select the next standard size up. Additionally, slight oversizing (10-15%) provides thermal headroom, compensates for voltage variations, and extends bearing life.
Use a VFD when: (1) variable speed is needed, (2) soft starting is required, (3) energy savings on variable torque loads are important, (4) the power supply cannot handle DOL starting current. VFDs also reduce mechanical stress on couplings and driven equipment.
本页所述的操作流程由 Vibromera 团队使用 Balanset-1A(一款用于现场转子平衡的便携式双通道动平衡仪及振动分析仪)开发并经过实地测试。
现场平衡电机,诊断电气和机械故障。
Nikolai Shelkovenko
Nikolai Shelkovenko是一名振动分析工程师,也是Vibromera的创始人兼首席执行官。 15年多来,他一直在现场——而非在试验台上——为旋转设备进行平衡:粉碎机、工业风机、破碎机、离心机、轴和主轴。正是这些实际工作催生了Balanset系列仪器——它们被设计为一种专业人员可以随身携带到机器旁、在现场独立使用的工具,而非实验室设备。 Vibromera成立于2017年,自2023年起总部设于葡萄牙波尔图。Balanset系列产品的研发、组装与支持均在此完成。旗舰产品是Balanset-1A,一款用于单平面及双平面平衡和振动诊断的便携式分析仪。 Nikolai亲自参与客户支持工作,处理各种棘手的平衡案例,并参与软件开发。他以任何语言为全球客户提供服务。