Gratis ingeniørværktøj
Ventilflowkoefficientberegner
Tovejs Kv/Cv-beregner til ventildimensionering. Beregn Kv ud fra flow + ΔP, flow ud fra Kv + ΔP eller ΔP ud fra Kv + flow. Til væskeflow.
Resultater
Kv for væskestrømning
Flowkoefficienten Kv (europæisk standard) er defineret som vandstrømmen i m³/t gennem en ventil ved et trykfald på 1 bar:
- Kv — flowkoefficient (m³/t ved ΔP = 1 bar)
- Q — volumenstrømningshastighed (m³/t)
- SG — specifik tyngdekraft (vand = 1,0; hydraulikolie ≈ 0,87)
- ΔP — trykfald over ventilen (bar)
Kv ↔ Cv-konvertering
Cv er den amerikanske/imperiale ækvivalent: flow i amerikanske GPM af vand ved ΔP = 1 psi og 60°F.
Vejledning til ventilstørrelser
| Ventiltype | Typisk Kv-område | Noter |
|---|---|---|
| Kugleventil DN15 | 10 - 40 | Fuld boring foretrækkes til hydraulik |
| Kugleventil DN25 | 50 - 200 | Lavt trykfald ved fuld åbning |
| Kugleventil DN50 | 250 - 800 | Mest almindelige i processen |
| Sædeventil DN25 | 8 - 15 | God til drosling/kontrol |
| Sædeventil DN50 | 25 - 50 | Højere ΔP end kugleventil |
| Spjældventil DN100 | 300 - 600 | Kompakt, store flow |
| Nåleventil | 0,1 – 5 | Finjustering af flow |
Praktisk eksempel
Givet: Q = 60 l/min hydraulikolie (SG = 0,87), ΔP = 5 bar
Omregn: Q = 60 / 1000 × 60 = 3,6 m³/t
Kv = 3,6 × √(0,87 / 5) = 3,6 × 0,417 = 1.50
Cv = 1,50 × 1,156 = 1.74
Anbefalet ventil Kv ≥ 1,50 × 1,3 = 1.95 (med sikkerhedsmargin)
⚠️ Bemærk: For kritiske anvendelser skal du også kontrollere: kavitationsindeks (FL-faktor), støjniveau, reguleringsområde og dynamisk respons. Se ventilproducentens dimensioneringssoftware for endeligt valg.
Kv is the volumetric flow of water at 15°C in m³/h that passes through a valve with a pressure drop of 1 bar. It is a measure of the valve's flow capacity — higher Kv means the valve can pass more flow for the same pressure drop.
Example: A valve with Kv = 10 passes 10 m³/h of water at 1 bar ΔP.
Kv — European/ISO standard. Flow in m³/h of water at ΔP = 1 bar.
Cv — US standard. Flow in US GPM of water at ΔP = 1 psi at 60°F.
Conversion: Cv = 1.156 × Kv (or Kv = 0.865 × Cv).
Steps for valve sizing:
- Calculate required Kv for your worst-case operating conditions
- Select a valve with Kv ≥ 1.3× calculated Kv (safety margin)
- Ensure the valve operates between 20–80% open at normal flow
- Check cavitation: ΔP should not exceed the valve's FL² × (P1 – Pv)
- Verify noise level is acceptable
No. Gas flow is compressible, so the liquid formula underestimates the required Kv. Use the gas-specific formula that includes upstream and downstream absolute pressures, temperature, and compressibility factor Z.
For critical flow (P2 < 0.53 × P1), the flow becomes choked and the formula changes further.
Cavitation occurs when the local pressure drops below the liquid's vapor pressure, forming bubbles that collapse violently — causing noise, vibration, and valve damage.
Flashing occurs when downstream pressure stays below vapor pressure — the liquid partially vaporizes permanently.
Check the valve's FL factor (pressure recovery factor). The allowable ΔP for no cavitation is: ΔPmax = FL² × (P1 – Pv), where Pv is vapor pressure.
Procedurerne beskrevet på denne side blev udviklet og felttestet af Vibromera-teamet ved hjælp af Balanset-1A, en bærbar tokanals afbalanceringsenhed og vibrationsanalysator til afbalancering af rotorer på stedet.
Professionelle feltbalanceringsinstrumenter og software. Anvendes i over 50 lande.
Nikolai Shelkovenko
Nikolai Shelkovenko er vibrationsanalyseingeniør samt stifter og direktør for Vibromera. I mere end 15 år har han afbalanceret roterende udstyr i marken frem for på en prøvebænk: flismaskiner, industriventilatorer, knusere, centrifuger, aksler og spindler. Det er dette arbejde, Balanset-instrumenterne er vokset ud af — de blev udviklet som et værktøj, en specialist kan tage med hen til maskinen og bruge alene på stedet, ikke som laboratorieudstyr. Vibromera blev grundlagt i 2017 og har siden 2023 haft base i Porto i Portugal. Udvikling, montage og support af Balanset-serien foregår her. Flagskibet er Balanset-1A, en bærbar analysator til afbalancering i ét og to planer og til vibrationsdiagnostik. Nikolai deltager personligt i kundesupporten, i arbejdet med vanskelige afbalanceringsopgaver og i udviklingen af softwaren. Han arbejder med kunder over hele verden, på ethvert sprog.