閥門流量係數計算器
用於閥門選型的雙向 Kv/Cv 計算器。可由流量 + ΔP 計算 Kv,由 Kv + ΔP 計算流量,或由 Kv + 流量計算 ΔP。適用於液體流動。
結果
液體流量的 Kv
流量係數 Kv(歐洲標準)定義為:在 1 bar 壓降下,通過閥門的水流量(m³/h):
- Kv — 流量係數(ΔP = 1 bar 時的 m³/h)
- Q — 體積流量(m³/h)
- SG — 比重(水 = 1.0;液壓油 ≈ 0.87)
- ΔP — 閥門兩端的壓降(bar)
Kv ↔ Cv 換算
Cv 是美國/英制等效值:在 ΔP = 1 psi 且 60°F 時,水的流量(美國 GPM)。
閥門選型指南
| 閥門類型 | 典型 Kv 範圍 | 備註 |
|---|---|---|
| DN15 球閥 | 10 – 40 | 液壓系統建議使用全通徑 |
| DN25 球閥 | 50 – 200 | 全開時壓降較低 |
| DN50 球閥 | 250 – 800 | 流程工業中最常見 |
| DN25 截止閥 | 8 – 15 | 適合節流/控制 |
| DN50 截止閥 | 25 – 50 | 壓降高於球閥 |
| DN100 蝶閥 | 300 – 600 | 結構緊湊,適用於大流量 |
| 針閥 | 0.1 – 5 | 精細流量調整 |
實務範例
已知: Q = 60 L/min 液壓油 (SG = 0.87),ΔP = 5 bar
換算:Q = 60 / 1000 × 60 = 3.6 m³/h
Kv = 3.6 × √(0.87 / 5) = 3.6 × 0.417 = 1.50
Cv = 1.50 × 1.156 = 1.74
建議閥門 Kv ≥ 1.50 × 1.3 = 1.95 (含安全裕度)
⚠️ 注意: 對於關鍵應用,還需檢查:空蝕指數 (FL 係數)、噪音等級、調節比以及動態響應。請諮詢閥門製造商的選型軟體以進行最終選型。
Kv is the volumetric flow of water at 15°C in m³/h that passes through a valve with a pressure drop of 1 bar. It is a measure of the valve's flow capacity — higher Kv means the valve can pass more flow for the same pressure drop.
Example: A valve with Kv = 10 passes 10 m³/h of water at 1 bar ΔP.
Kv — European/ISO standard. Flow in m³/h of water at ΔP = 1 bar.
Cv — US standard. Flow in US GPM of water at ΔP = 1 psi at 60°F.
Conversion: Cv = 1.156 × Kv (or Kv = 0.865 × Cv).
Steps for valve sizing:
- Calculate required Kv for your worst-case operating conditions
- Select a valve with Kv ≥ 1.3× calculated Kv (safety margin)
- Ensure the valve operates between 20–80% open at normal flow
- Check cavitation: ΔP should not exceed the valve's FL² × (P1 – Pv)
- Verify noise level is acceptable
No. Gas flow is compressible, so the liquid formula underestimates the required Kv. Use the gas-specific formula that includes upstream and downstream absolute pressures, temperature, and compressibility factor Z.
For critical flow (P2 < 0.53 × P1), the flow becomes choked and the formula changes further.
Cavitation occurs when the local pressure drops below the liquid's vapor pressure, forming bubbles that collapse violently — causing noise, vibration, and valve damage.
Flashing occurs when downstream pressure stays below vapor pressure — the liquid partially vaporizes permanently.
Check the valve's FL factor (pressure recovery factor). The allowable ΔP for no cavitation is: ΔPmax = FL² × (P1 – Pv), where Pv is vapor pressure.
本頁所述的操作流程由 Vibromera 團隊使用 Balanset-1A(一款用於現場轉子平衡的便攜式雙通道動平衡儀及振動分析儀)開發並經過實地測試。
專業現場動平衡校正儀器與軟體。已在 50 多個國家使用。
Nikolai Shelkovenko
Nikolai Shelkovenko是一名振動分析工程師,也是Vibromera的創辦人兼執行長。 15年多來,他一直在現場——而非在試驗台上——為旋轉設備進行動平衡校正:粉碎機、工業風機、破碎機、離心機、軸與主軸。正是這些實際工作催生了Balanset系列儀器——它們被設計為一種專業人員可以隨身攜帶到機器旁、在現場獨立使用的工具,而非實驗室設備。 Vibromera成立於2017年,自2023年起總部設於葡萄牙波爾圖。Balanset系列產品的研發、組裝與支援均在此完成。旗艦產品是Balanset-1A,一款用於單平面及雙平面動平衡校正與振動診斷的可攜式分析儀。 Nikolai親自參與客戶支援工作,處理各種棘手的動平衡校正案例,並參與軟體開發。他以任何語言為全球客戶提供服務。