Mød Vibromera.com — vores nye internationale hjemmeside. Besøg Vibromera.com →

Gratis ingeniørværktøj

Ventilflowkoefficientberegner

Tovejs Kv/Cv-beregner til ventildimensionering. Beregn Kv ud fra flow + ΔP, flow ud fra Kv + ΔP eller ΔP ud fra Kv + flow. Til væskeflow.

Kv / Cv Væske Tovejs Cv = 1,156 × Kv
Hurtige forudindstillinger

Resultater

Flowkoefficient Kv
—
Cv (USA)
—
Flowmængde
—
Trykfald
—
Anbefalet ventil Kv (×1,3)
—
Anbefalet ventil Cv (×1,3)
—

Kv for væskestrømning

Flowkoefficienten Kv (europæisk standard) er defineret som vandstrømmen i m³/t gennem en ventil ved et trykfald på 1 bar:

  • Kv — flowkoefficient (m³/t ved ΔP = 1 bar)
  • Q — volumenstrømningshastighed (m³/t)
  • SG — specifik tyngdekraft (vand = 1,0; hydraulikolie ≈ 0,87)
  • ΔP — trykfald over ventilen (bar)

Kv ↔ Cv-konvertering

Cv er den amerikanske/imperiale ækvivalent: flow i amerikanske GPM af vand ved ΔP = 1 psi og 60°F.

Vejledning til ventilstørrelser

VentiltypeTypisk Kv-områdeNoter
Kugleventil DN1510 - 40Fuld boring foretrækkes til hydraulik
Kugleventil DN2550 - 200Lavt trykfald ved fuld åbning
Kugleventil DN50250 - 800Mest almindelige i processen
Sædeventil DN258 - 15God til drosling/kontrol
Sædeventil DN5025 - 50Højere ΔP end kugleventil
Spjældventil DN100300 - 600Kompakt, store flow
Nåleventil0,1 – 5Finjustering af flow

Praktisk eksempel

Eksempel — Hydraulisk retningsventil

Givet: Q = 60 l/min hydraulikolie (SG = 0,87), ΔP = 5 bar

Omregn: Q = 60 / 1000 × 60 = 3,6 m³/t

Kv = 3,6 × √(0,87 / 5) = 3,6 × 0,417 = 1.50

Cv = 1,50 × 1,156 = 1.74

Anbefalet ventil Kv ≥ 1,50 × 1,3 = 1.95 (med sikkerhedsmargin)

⚠️ Bemærk: For kritiske anvendelser skal du også kontrollere: kavitationsindeks (FL-faktor), støjniveau, reguleringsområde og dynamisk respons. Se ventilproducentens dimensioneringssoftware for endeligt valg.

Kv is the volumetric flow of water at 15°C in m³/h that passes through a valve with a pressure drop of 1 bar. It is a measure of the valve's flow capacity — higher Kv means the valve can pass more flow for the same pressure drop.

Example: A valve with Kv = 10 passes 10 m³/h of water at 1 bar ΔP.

Kv — European/ISO standard. Flow in m³/h of water at ΔP = 1 bar.

Cv — US standard. Flow in US GPM of water at ΔP = 1 psi at 60°F.

Conversion: Cv = 1.156 × Kv (or Kv = 0.865 × Cv).

Steps for valve sizing:

  • Calculate required Kv for your worst-case operating conditions
  • Select a valve with Kv ≥ 1.3× calculated Kv (safety margin)
  • Ensure the valve operates between 20–80% open at normal flow
  • Check cavitation: ΔP should not exceed the valve's FL² × (P1 – Pv)
  • Verify noise level is acceptable

No. Gas flow is compressible, so the liquid formula underestimates the required Kv. Use the gas-specific formula that includes upstream and downstream absolute pressures, temperature, and compressibility factor Z.

For critical flow (P2 < 0.53 × P1), the flow becomes choked and the formula changes further.

Cavitation occurs when the local pressure drops below the liquid's vapor pressure, forming bubbles that collapse violently — causing noise, vibration, and valve damage.

Flashing occurs when downstream pressure stays below vapor pressure — the liquid partially vaporizes permanently.

Check the valve's FL factor (pressure recovery factor). The allowable ΔP for no cavitation is: ΔPmax = FL² × (P1 – Pv), where Pv is vapor pressure.

Procedurerne beskrevet på denne side blev udviklet og felttestet af Vibromera-teamet ved hjælp af Balanset-1A, en bærbar tokanals afbalanceringsenhed og vibrationsanalysator til afbalancering af rotorer på stedet.

Vibromera — Bærbar balancering og vibrationsanalyse
Professionelle feltbalanceringsinstrumenter og software. Anvendes i over 50 lande.
Læs mere om Vibromeras balanceringsinstrumenter
Kategorier:

Nikolai Shelkovenko

Nikolai Shelkovenko

Nikolai Shelkovenko er vibrationsanalyseingeniør samt stifter og direktør for Vibromera. I mere end 15 år har han afbalanceret roterende udstyr i marken frem for på en prøvebænk: flismaskiner, industriventilatorer, knusere, centrifuger, aksler og spindler. Det er dette arbejde, Balanset-instrumenterne er vokset ud af — de blev udviklet som et værktøj, en specialist kan tage med hen til maskinen og bruge alene på stedet, ikke som laboratorieudstyr. Vibromera blev grundlagt i 2017 og har siden 2023 haft base i Porto i Portugal. Udvikling, montage og support af Balanset-serien foregår her. Flagskibet er Balanset-1A, en bærbar analysator til afbalancering i ét og to planer og til vibrationsdiagnostik. Nikolai deltager personligt i kundesupporten, i arbejdet med vanskelige afbalanceringsopgaver og i udviklingen af softwaren. Han arbejder med kunder over hele verden, på ethvert sprog.

WhatsApp
Balanset-1A · €1975Spørg ingeniøren