Besplatni inženjerski alat
Kalkulator koeficijenta protoka ventila
Dvosmjerni Kv/Cv kalkulator za dimenzioniranje ventila. Izračunajte Kv iz protoka + ΔP, protok iz Kv + ΔP, ili ΔP iz Kv + protoka. Za protok tekućine.
Rezultati
Kv za protok tekućine
Koeficijent protoka Kv (europski standard) definiran je kao protok vode u m³/h kroz ventil pri padu tlaka od 1 bara:
- Kv — koeficijent protoka (m³/h pri ΔP = 1 bar)
- Q — volumetrijski protok (m³/h)
- SG — specifična težina (voda = 1,0; hidrauličko ulje ≈ 0,87)
- ΔP — pad tlaka na ventilu (bar)
Pretvorba Kv ↔ Cv
Cv je američki/imperijalni ekvivalent: protok u američkim GPM vode pri ΔP = 1 psi i 60°F.
Vodič za dimenzioniranje ventila
| Vrsta ventila | Tipični Kv raspon | Bilješke |
|---|---|---|
| Kuglasti ventil DN15 | 10 – 40 | Za hidrauliku se preferira puni provrt |
| Kuglasti ventil DN25 | 50 – 200 | Nizak pad tlaka pri potpunom otvaranju |
| Kuglasti ventil DN50 | 250 – 800 | Najčešći u procesu |
| Globusni ventil DN25 | 8 – 15 | Dobro za gušenje/kontrolu |
| Globusni ventil DN50 | 25 – 50 | Veći ΔP nego kod kuglastog ventila |
| Leptir DN100 | 300 – 600 | Kompaktni, veliki protoci |
| Igličasti ventil | 0,1 – 5 | Fino podešavanje protoka |
Praktični primjer
Dano: Q = 60 L/min hidrauličkog ulja (SG = 0,87), ΔP = 5 bara
Pretvori: Q = 60 / 1000 × 60 = 3,6 m³/h
Kv = 3,6 × √(0,87 / 5) = 3,6 × 0,417 = 1.50
Cv = 1,50 × 1,156 = 1.74
Preporučeni ventil Kv ≥ 1,50 × 1,3 = 1.95 (s sigurnosnom marginom)
⚠️ Napomena: Za kritične primjene provjerite i: indeks kavitacije (FL faktor), razinu buke, regulacijski raspon i dinamički odziv. Za konačni odabir upotrijebite softver proizvođača ventila za dimenzioniranje.
Kv is the volumetric flow of water at 15°C in m³/h that passes through a valve with a pressure drop of 1 bar. It is a measure of the valve's flow capacity — higher Kv means the valve can pass more flow for the same pressure drop.
Example: A valve with Kv = 10 passes 10 m³/h of water at 1 bar ΔP.
Kv — European/ISO standard. Flow in m³/h of water at ΔP = 1 bar.
Cv — US standard. Flow in US GPM of water at ΔP = 1 psi at 60°F.
Conversion: Cv = 1.156 × Kv (or Kv = 0.865 × Cv).
Steps for valve sizing:
- Calculate required Kv for your worst-case operating conditions
- Select a valve with Kv ≥ 1.3× calculated Kv (safety margin)
- Ensure the valve operates between 20–80% open at normal flow
- Check cavitation: ΔP should not exceed the valve's FL² × (P1 – Pv)
- Verify noise level is acceptable
No. Gas flow is compressible, so the liquid formula underestimates the required Kv. Use the gas-specific formula that includes upstream and downstream absolute pressures, temperature, and compressibility factor Z.
For critical flow (P2 < 0.53 × P1), the flow becomes choked and the formula changes further.
Cavitation occurs when the local pressure drops below the liquid's vapor pressure, forming bubbles that collapse violently — causing noise, vibration, and valve damage.
Flashing occurs when downstream pressure stays below vapor pressure — the liquid partially vaporizes permanently.
Check the valve's FL factor (pressure recovery factor). The allowable ΔP for no cavitation is: ΔPmax = FL² × (P1 – Pv), where Pv is vapor pressure.
Postupke opisane na ovoj stranici razvio je i terenski testirao tim Vibromera koristeći Balanset-1A, prijenosni dvokanalni balanser i analizator vibracija za balansiranje rotora na terenu.
Profesionalni instrumenti i softver za balansiranje na terenu. Koriste se u više od 50 zemalja.
Nikolai Shelkovenko
Nikolai Shelkovenko inženjer je analize vibracija te osnivač i izvršni direktor tvrtke Vibromera. Više od 15 godina balansira rotacijsku opremu na terenu, a ne na ispitnom stolu: malčere, industrijske ventilatore, drobilice, centrifuge, vratila i vretena. Upravo je iz tog rada nastala oprema Balanset — osmišljena je kao alat koji stručnjak može ponijeti do stroja i sam njime raditi na licu mjesta, a ne kao laboratorijska oprema. Vibromera je osnovana 2017. godine, a od 2023. sjedište joj je u Portu u Portugalu. Ovdje se odvijaju razvoj, sklapanje i podrška za liniju Balanset. Vodeći instrument je Balanset-1A, prijenosni analizator za balansiranje u jednoj i dvije ravnine te za dijagnostiku vibracija. Nikolai je osobno uključen u podršku korisnicima, u rješavanje složenih slučajeva balansiranja i u razvoj programske podrške. Radi s korisnicima diljem svijeta, na bilo kojem jeziku.