Brezplačno inženirsko orodje
Kalkulator koeficienta pretoka ventila
Dvosmerni kalkulator Kv/Cv za dimenzioniranje ventilov. Izračunajte Kv iz pretoka + ΔP, pretok iz Kv + ΔP ali ΔP iz Kv + pretoka. Za pretok tekočine.
Rezultati
Kv za pretok tekočine
Koeficient pretoka Kv (evropski standard) je definiran kot pretok vode v m³/h skozi ventil pri padcu tlaka 1 bar:
- Kv — koeficient pretoka (m³/h pri ΔP = 1 bar)
- Q — volumetrični pretok (m³/h)
- SG — relativna gostota (voda = 1,0; hidravlično olje ≈ 0,87)
- ΔP — padec tlaka na ventilu (bar)
Pretvorba Kv ↔ Cv
Cv je ameriški/imperialni ekvivalent: pretok vode v ameriških galonah na minuto (GPM) pri ΔP = 1 psi in 60 °F.
Vodnik za dimenzioniranje ventilov
| Vrsta ventila | Tipično območje Kv | Opombe |
|---|---|---|
| Kroglični ventil DN15 | 10–40 | Za hidravliko je prednost polne izvrtine |
| Kroglični ventil DN25 | 50–200 | Nizek padec tlaka pri polnem odprtju |
| Kroglični ventil DN50 | 250–800 | Najpogostejši v procesu |
| Sedežni ventil DN25 | 8–15 | Dobro za dušenje/nadzor |
| Sedežni ventil DN50 | 25–50 | Višji ΔP kot pri krogličnem ventilu |
| Metulj DN100 | 300–600 | Kompaktni, veliki pretoki |
| Igelni ventil | 0,1 – 5 | Fina nastavitev pretoka |
Praktični primer
Dano: Q = 60 L/min hidravlično olje (SG = 0,87), ΔP = 5 bar
Pretvori: Q = 60 / 1000 × 60 = 3,6 m³/h
Kv = 3,6 × √(0,87 / 5) = 3,6 × 0,417 = 1.50
Cv = 1,50 × 1,156 = 1.74
Priporočeni ventil Kv ≥ 1,50 × 1,3 = 1.95 (z varnostno rezervo)
⚠️ Opomba: Za kritične aplikacije preverite tudi: indeks kavitacije (faktor FL), raven hrupa, nastavljivost in dinamični odziv. Za končno izbiro se posvetujte s programsko opremo proizvajalca ventilov za dimenzioniranje.
Kv is the volumetric flow of water at 15°C in m³/h that passes through a valve with a pressure drop of 1 bar. It is a measure of the valve's flow capacity — higher Kv means the valve can pass more flow for the same pressure drop.
Example: A valve with Kv = 10 passes 10 m³/h of water at 1 bar ΔP.
Kv — European/ISO standard. Flow in m³/h of water at ΔP = 1 bar.
Cv — US standard. Flow in US GPM of water at ΔP = 1 psi at 60°F.
Conversion: Cv = 1.156 × Kv (or Kv = 0.865 × Cv).
Steps for valve sizing:
- Calculate required Kv for your worst-case operating conditions
- Select a valve with Kv ≥ 1.3× calculated Kv (safety margin)
- Ensure the valve operates between 20–80% open at normal flow
- Check cavitation: ΔP should not exceed the valve's FL² × (P1 – Pv)
- Verify noise level is acceptable
No. Gas flow is compressible, so the liquid formula underestimates the required Kv. Use the gas-specific formula that includes upstream and downstream absolute pressures, temperature, and compressibility factor Z.
For critical flow (P2 < 0.53 × P1), the flow becomes choked and the formula changes further.
Cavitation occurs when the local pressure drops below the liquid's vapor pressure, forming bubbles that collapse violently — causing noise, vibration, and valve damage.
Flashing occurs when downstream pressure stays below vapor pressure — the liquid partially vaporizes permanently.
Check the valve's FL factor (pressure recovery factor). The allowable ΔP for no cavitation is: ΔPmax = FL² × (P1 – Pv), where Pv is vapor pressure.
Postopki, opisani na tej strani, so bili razviti in terensko preizkušeni s strani ekipe Vibromera z uporabo naprave Balanset-1A, prenosnega dvokanalnega uravnoteževalnika in analizatorja vibracij za uravnoteženje rotorjev na mestu uporabe.
Profesionalni instrumenti in programska oprema za uravnoteženje na terenu. Uporabljajo se v več kot 50 državah.
Nikolai Shelkovenko
Nikolai Shelkovenko je inženir vibracijske analize ter ustanovitelj in izvršni direktor podjetja Vibromera. Že več kot 15 let uravnotežuje vrtečo se opremo na terenu, in ne na preizkuševališču: mulčerje, industrijske ventilatorje, drobilnike, centrifuge, gredi in vretena. Prav iz tega dela so nastali instrumenti Balanset — zasnovani so bili kot orodje, ki ga strokovnjak lahko prinese do stroja in ga uporabi sam, na mestu samem, ne pa kot laboratorijska oprema. Vibromera je bila ustanovljena leta 2017, od leta 2023 pa ima sedež v Portu na Portugalskem. Tu potekajo razvoj, sestavljanje in podpora za linijo Balanset. Vodilni instrument je Balanset-1A, prenosni analizator za enoravninsko in dvoravninsko uravnoteženje ter za vibracijsko diagnostiko. Nikolai osebno sodeluje pri podpori strankam, pri reševanju zahtevnih primerov uravnoteženja in pri razvoju programske opreme. S strankami dela po vsem svetu, v katerem koli jeziku.