Free Engineering Tool #048

Bearing Fit & Tolerance Selection

Select recommended shaft and housing tolerance zones for rolling-bearing mounting, based on bearing-manufacturer catalogue guidance using the ISO 286 tolerance system. Choose load type and bearing bore diameter.

ISO 286 Shaft & Housing Fits Tolerance Zones
Quick presets

Recommended Fits

Shaft Tolerance Zone
—
Housing Tolerance Zone
—
Fit Type — Shaft
—
Fit Type — Housing
—
Mounting Note
—

General Principle

The ring subjected to rotating load should have an interference fit to prevent creep. The ring with stationary load can have a looser fit for ease of mounting and axial displacement.

Shaft Fit Recommendations (Rotating Inner Ring)

LoadBall BearingsRoller BearingsFit Type
Light / variable directionj5, j6j5, j6Transition
Normalk5, k6m5, m6Transition / Light interference
Heavy / shockm5, m6n6, p6Interference

Housing Fit Recommendations (Stationary Outer Ring)

ConditionLocatingNon-locatingFit Type
Normal loadsJ7, H7H7, G7Sliding / transition
Heavy loadsK7, M7H7, J7Transition
Light, easy dismountH7G7, F7Clearance
Rotating outer ringM7, N7K7, M7Interference

ℹ️ Tip: For bearings with bore d > 100 mm, the next tighter tolerance class is often recommended due to the lower relative interference. Hollow shafts also require tighter fits.

⚠️ Note: These are general recommendations. Always verify with the specific bearing manufacturer’s guidelines (SKF, FAG/Schaeffler, NSK, Timken) for your application.

Correct fit ensures the ring with rotating load has an interference fit to prevent creep (ring rotation on the seat), while the non-rotating ring has a looser fit for easy mounting and to allow axial float if needed.

The most common case: the shaft rotates and the housing is stationary. The inner ring needs a tight fit on the shaft, and the outer ring gets a sliding or transition fit in the housing.

For rotating inner ring with normal loads: k5 for ball bearings, m5 for roller bearings. For heavy/shock loads, use m6 or n6. For light loads, j5 is sufficient.

A transition fit (j5, k5) may result in either slight clearance or slight interference. An interference fit (m5, n6, p6) always gives the shaft larger than the bore, requiring force or heating for assembly.

Use a loose housing fit (H7, G7) when the outer ring must be free to move axially (non-locating position), when the housing is split, or when the outer ring load is stationary.

The procedures described on this page were developed and field-tested by the Vibromera team using the Balanset-1A, a portable dual-channel balancer and vibration analyzer for on-site rotor balancing.

Vibromera — Portable Balancing & Vibration Analysis
Professional vibration analyzers for bearing condition monitoring. Used in 50+ countries.
Learn more about Vibromera balancing instruments

© 2024–2026 Vibromera — Engineering Calculators

Based on bearing-manufacturer catalogue guidance (ISO 286 tolerance zones). Calculator #048. Last updated: February 2026