Gratis ingeniørværktøj #048
Valg af lejepasning og tolerance
Vælg anbefalede tolerancezoner for aksel og hus til montering af rullelejer baseret på vejledning fra lejeproducenters kataloger med ISO 286-tolerancesystemet. Vælg belastningstype og lejets boringdiameter.
Anbefalede pasformer
Generelt princip
Ringen, der udsættes for roterende belastning, skal have en prespasning for at forhindre krybning. Ringen med stationær belastning kan have en løsere pasform for at lette montering og aksial forskydning.
Anbefalinger for akseltilpasning (roterende inderring)
| Belastning | Kuglelejer | Rullelejer | Pasformstype |
|---|---|---|---|
| Let / variabel retning | j5, j6 | j5, j6 | Overgang |
| Normal | k5, k6 | m5, m6 | Overgang / let interferens |
| Tung / chok | m5, m6 | n6, p6 | Interferens |
Anbefalinger til hustilpasning (stationær ydre ring)
| Tilstand | Lokalisering | Ikke-lokalisering | Pasformstype |
|---|---|---|---|
| Normale belastninger | J7, H7 | H7, G7 | Glidende / overgang |
| Tunge læs | K7, M7 | H7, J7 | Overgang |
| Let, nem afmontering | H7 | G7, F7 | Spillerum |
| Roterende ydre ring | M7, N7 | K7, M7 | Interferens |
ℹ️ Tip: For lejer med boring d > 100 mm anbefales ofte den næstsnævreste toleranceklasse på grund af den lavere relative interferens. Hule aksler kræver også strammere pasform.
⚠️ Bemærk: Dette er generelle anbefalinger. Kontroller altid den specifikke lejeproducents retningslinjer (SKF, FAG/Schaeffler, NSK, Timken) for din anvendelse.
Correct fit ensures the ring with rotating load has an interference fit to prevent creep (ring rotation on the seat), while the non-rotating ring has a looser fit for easy mounting and to allow axial float if needed.
The most common case: the shaft rotates and the housing is stationary. The inner ring needs a tight fit on the shaft, and the outer ring gets a sliding or transition fit in the housing.
For rotating inner ring with normal loads: k5 for ball bearings, m5 for roller bearings. For heavy/shock loads, use m6 or n6. For light loads, j5 is sufficient.
A transition fit (j5, k5) may result in either slight clearance or slight interference. An interference fit (m5, n6, p6) always gives the shaft larger than the bore, requiring force or heating for assembly.
Use a loose housing fit (H7, G7) when the outer ring must be free to move axially (non-locating position), when the housing is split, or when the outer ring load is stationary.
Procedurerne beskrevet på denne side blev udviklet og felttestet af Vibromera-teamet ved hjælp af Balanset-1A, en bærbar tokanals afbalanceringsenhed og vibrationsanalysator til afbalancering af rotorer på stedet.
Professionelle vibrationsanalysatorer til overvågning af lejers tilstand. Anvendes i over 50 lande.