Tasuta inseneritööriist #046
Laagri ekvivalentse dünaamilise koormuse kalkulaator
Arvutage ekvivalentne dünaamiline laagrikoormus P = X·Fr + Y·Fa. Valib automaatselt X- ja Y-tegurid laagritüübi ja F-i põhjal.a/Fr suhe vs. e-väärtus.
Tulemused
Ekvivalentne dünaamiline koormus
Ekvivalentne dünaamiline laagrikoormus ühendab radiaal- ja aksiaaljõud üheks väärtuseks:
Tingimus on järgmine: kui Fa/Fr ≤ e, siis P = Fr. Kui Fa/Fr > e, siis P = X·Fr + Y·Fa.
X-, Y- ja e-tegurid laagritüübi järgi
| Laagri tüüp | e | X (Fa/Fr ≤ e) | Y (Fa/Fr ≤ e) | X (Fa/Fr > e) | Y (Fa/Fr > e) |
|---|---|---|---|---|---|
| Sügava soonega kuullaager (DGBB) | 0.19 | 1 | 0 | 0.56 | 2.30 |
| Nurkkontakt 15° | 0.38 | 1 | 0 | 0.44 | 1.47 |
| Nurkkontakt 25° | 0.68 | 1 | 0 | 0.41 | 0.87 |
| Nurkkontakt 40° | 1.14 | 1 | 0 | 0.35 | 0.57 |
| Isejoonduv kuullaager | 0.40 | 1 | 0 | 0.65 | 1.71 |
| Silindriline rulllaager | — | 1 | 0 | — | — |
| Koonusrulllaager | 0.37 | 1 | 0 | 0.40 | 1.60 |
| Sfääriline rulllaager | 0.27 | 1 | 0 | 0.67 | 2.35 |
ℹ️ Märkus: Ülaltoodud väärtused on lihtsustatud tüüpilised väärtused. Täpsed X, Y ja e väärtused sõltuvad konkreetsest laagriseeriast ja suhtest C.0/Fa. Täpsete väärtuste saamiseks vaadake tootja katalooge.
Praktiline näide
Antud: Fr = 8 kN, Fa = 3 kN
Fa/Fr = 3/8 = 0.375 > e = 0.19 → aksiaalne koormus on märkimisväärne
P = 0.56 × 8 + 2.30 × 3 = 4.48 + 6.90 = 11.38 kN
The equivalent dynamic load P is a hypothetical constant radial load that would give the same bearing life as the actual combined radial and axial loads. It is calculated as P = X·Fr + Y·Fa.
X is the radial load factor and Y is the axial load factor. When Fa/Fr ≤ e, the axial load has negligible effect (X=1, Y=0). When Fa/Fr > e, both X and Y apply to account for the combined loading.
The e-value is a threshold ratio specific to each bearing type. It determines whether the axial load significantly affects bearing life. Different bearing types have different e-values based on their internal geometry and contact angle.
For pure radial load (Fa = 0), the equivalent load simplifies to P = Fr. No axial factor applies since Fa/Fr = 0, which is always ≤ e.
This calculator computes the dynamic equivalent load P for L10 life calculations. For the static equivalent load P0, the formula is similar but uses different X0 and Y0 factors. Use the Bearing Static Safety Factor calculator for P0 assessment.
Sellel lehel kirjeldatud protseduurid töötas välja ja testis välitingimustes Vibromera meeskond, kasutades Balanset-1A-d, kaasaskantavat kahekanalilist tasakaalustusseadet ja vibratsioonianalüsaatorit rootorite tasakaalustamiseks kohapeal.
Professionaalsed tasakaalustusinstrumendid ja vibratsioonianalüsaatorid. Kasutusel enam kui 50 riigis.