Besplatni inženjerski alat #046
Kalkulator ekvivalentne dinamičke sile ležaja
Izračunajte ekvivalentnu dinamičku opterećenja ležaja P = X·Fr + Y·Fa. Automatski bira X,Y faktore na osnovu tipa ležaja i Fa/Fr omjer naspram e-vrijednosti.
Rezultati
Ekvivalentna dinamička opterećenja
Ekvivalentna dinamička opterećenja ležaja kombinuje radijalne i aksijalne sile u jednu vrijednost:
Uslov je: ako je Fa/Fr ≤ e, tada P = Fr. Ako Fa/Fr > e, tada P = X·Fr + Y·Fa.
Faktori X, Y i e po tipu ležaja
| Tip ležaja | e | X (Fa/Fr ≤ e) | Y (Fa/Fr ≤ e) | X (Fa/Fr > e) | Y (Fa/Fr > e) |
|---|---|---|---|---|---|
| Duboki žljeb kuglični (DGBB) | 0.19 | 1 | 0 | 0.56 | 2.30 |
| Kosi kontakt 15° | 0.38 | 1 | 0 | 0.44 | 1.47 |
| Kosi kontakt 25° | 0.68 | 1 | 0 | 0.41 | 0.87 |
| Kosi kontakt 40° | 1.14 | 1 | 0 | 0.35 | 0.57 |
| Samouspravljajući kuglični | 0.40 | 1 | 0 | 0.65 | 1.71 |
| Valjkasti cilindrični | — | 1 | 0 | — | — |
| Konusni valjkasti ležaj | 0.37 | 1 | 0 | 0.40 | 1.60 |
| Sferni valjkasti | 0.27 | 1 | 0 | 0.67 | 2.35 |
ℹ️ Napomena: Vrednosti iznad su pojednostavljene tipične vrednosti. Tačne vrednosti X, Y i e zavise od specifične serije ležaja i odnosa C0/Fa. Konsultujte kataloge proizvođača za precizne vrednosti.
Praktični primjer
Zadano: Fr = 8 kN, Fa = 3 kN
Fa/Fr = 3/8 = 0.375 > e = 0.19 → aksijalno opterećenje je značajno
P = 0.56 × 8 + 2.30 × 3 = 4.48 + 6.90 = 11.38 kN
The equivalent dynamic load P is a hypothetical constant radial load that would give the same bearing life as the actual combined radial and axial loads. It is calculated as P = X·Fr + Y·Fa.
X is the radial load factor and Y is the axial load factor. When Fa/Fr ≤ e, the axial load has negligible effect (X=1, Y=0). When Fa/Fr > e, both X and Y apply to account for the combined loading.
The e-value is a threshold ratio specific to each bearing type. It determines whether the axial load significantly affects bearing life. Different bearing types have different e-values based on their internal geometry and contact angle.
For pure radial load (Fa = 0), the equivalent load simplifies to P = Fr. No axial factor applies since Fa/Fr = 0, which is always ≤ e.
This calculator computes the dynamic equivalent load P for L10 life calculations. For the static equivalent load P0, the formula is similar but uses different X0 and Y0 factors. Use the Bearing Static Safety Factor calculator for P0 assessment.
Procedure opisane na ovoj stranici razvio je i terenski testirao tim Vibromera koristeći Balanset-1A, prenosivi dvokanalni balanser i analizator vibracija za balansiranje rotora na licu mjesta.
Profesionalni instrumenti za balansiranje u poljskim uslovima i analizatori vibracija. Korišćeni u 50+ zemalja.