Zana ya Uhandisi Isiyolipisha
Kichanganuzi cha Usafi wa Mafuta ya Majimaji
Kikokotoo cha msimbo wa ISO 4406 chenye utafutaji wa kiwango cha usafi kinachohitajika, mapendekezo ya β-ratio ya kichujio, na mwongozo wa muda wa sampuli kulingana na aina ya sehemu.
Matokeo ya Uchambuzi
Kipimo cha Msimbo wa ISO 4406
Each code number R represents a particle count range: 2^(R-1) × 0.01 to 2^R × 0.01 particles per mL (simplified). The code doubles with each increment.
Lengo la Usafi kwa Sehemu
| Sehemu | Msimbo wa ISO Lengwa | Filter μm | β-ratio |
|---|---|---|---|
| Servo valves | 16/14/11 | 3 μm | β₃ ≥ 200 |
| Vali za proportional | 18/16/13 | 6 μm | β₆ ≥ 200 |
| Pampu za pistoni/injini | 17/15/12 | 6 μm | β₆ ≥ 200 |
| Vane pumps | 18/16/13 | 10 μm | β₁₀ ≥ 200 |
| Pampu za gia, vali za kawaida | 20/18/15 | 10 μm | β₁₀ ≥ 75 |
| Cylinders only | 21/19/16 | 25 μm | β₂₅ ≥ 75 |
Makadirio ya Muda wa Kusafisha
Idadi ya takriban ya mizunguko ya kusafisha inayohitajika kupunguza uchafuzi kwa kiwango kimoja cha ISO:
Mfano wa Vitendo
Target: 16/14/11 → inahitajika kupunguza kwa viwango 4 vya ISO
Kila kiwango cha ISO ≈ mizunguko 2 ya mfumo mzima kupitia uchujaji unaofaa
200 L system, 60 L/min flow: turnover = 200/60 = 3.3 min
Est. cleanup: 4 levels × 2 turnovers × 3.3 min ≈ 26 minutes ya uchujaji wa mzunguko wa pembeni (kidney-loop)
Vyombo vya Kitaalamu. Vinatumika katika nchi 50+.