Muhandislik uchun bepul vosita
Termografiya harorat chegaralari
Infrakizil tekshiruv natijalarini ISO 18434 bo'yicha tasniflang. Og'irlik toifasi va tavsiya etilgan choralarni olish uchun komponent turini va mos yozuvdan yuqori o'lchangan ΔT qiymatini kiriting.
ISO 18434NETA MTSIR Inspection
Classification
Severity
—
Measured ΔT
—
Priority
—
Tavsiya etilgan harakat
—
Ushbu komponent uchun harorat chegaralari
—
Harorat o'lchagich
Elektr komponentlari (NETA MTS)
| ΔT (°C) | Severity | Priority | Action |
|---|---|---|---|
| 1–10 | Minor | 4 | Kuzatishni davom ettiring, qulay vaqtda ta'mirlang |
| 10–35 | Intermediate | 3 | Ta'mirlashni keyingi rejalashtirilgan to'xtatish vaqtiga rejalashtiring |
| 35–75 | Serious | 2 | Imkon qadar tezroq ta'mirlang |
| >75 | Critical | 1 | Zudlik bilan chora ko'ring — nosozlik/yong'in xavfi mavjud |
Mexanik komponentlar
| Component | Minor | Intermediate | Serious | Critical |
|---|---|---|---|---|
| Motor body | <10°C | 10–25°C | 25–40°C | >40°C |
| Podshipnik korpusi | <10°C | 10–20°C | 20–35°C | >35°C |
| Coupling | <5°C | 5–15°C | 15–25°C | >25°C |
| Steam trap | <20°C | 20–40°C | 40–60°C | >60°C |
| Insulation | <5°C | 5–15°C | 15–30°C | >30°C |
Vibromera — Ko'chma Balanslashtirish & Tebranish Tahlili
Keng qamrovli texnik holat monitoringi uchun vibratsiya tahlilini termografiya bilan birlashtiring.
Learn MoreKeng qamrovli texnik holat monitoringi uchun vibratsiya tahlilini termografiya bilan birlashtiring.