免費工程工具
馬達容量計算器
根據負載參數計算所需馬達功率,並取得建議的標準 IEC 馬達尺寸,包含啟動電流與扭矩估算。
馬達選型
馬達功率計算
IEC 標準馬達尺寸 (kW)
| 範圍 | 可用尺寸 (kW) |
|---|---|
| 小型 | 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3.0, 4.0 |
| 中 | 5.5, 7.5, 11, 15, 18.5, 22, 30, 37 |
| 大型 | 45, 55, 75, 90, 110, 132, 160, 200, 250, 315 |
啟動電流倍率
- DOL — 6–8× 額定電流
- 星三角啟動 — 2–3× 額定電流(DOL 的 ÷3)
- 軟啟動器 — 2–4× 額定電流
- VFD — 1–1.5× 額定電流
ℹ️ 提示: 請始終選擇高於計算需求之下一個標準尺寸。放大一個級距可提供熱餘裕並延長軸承壽命。
Service factor (SF) accounts for operating conditions beyond rated values. Use 1.0 for ideal conditions, 1.15 for moderate ambient or occasional overloads, 1.25 for harsh environments, and 1.5 for severe duty with frequent starts or high-inertia loads.
Constant torque loads (conveyors, positive displacement pumps) require the same torque regardless of speed — power is proportional to speed. Variable torque loads (centrifugal fans/pumps) have torque proportional to speed² and power proportional to speed³ — they need much less power at reduced speed.
Motors are only made in standard sizes. You must always select the next standard size up. Additionally, slight oversizing (10-15%) provides thermal headroom, compensates for voltage variations, and extends bearing life.
Use a VFD when: (1) variable speed is needed, (2) soft starting is required, (3) energy savings on variable torque loads are important, (4) the power supply cannot handle DOL starting current. VFDs also reduce mechanical stress on couplings and driven equipment.
本頁所述的操作流程由 Vibromera 團隊使用 Balanset-1A(一款用於現場轉子平衡的便攜式雙通道動平衡儀及振動分析儀)開發並經過實地測試。
現場對馬達進行動平衡校正,診斷電氣與機械故障。
Nikolai Shelkovenko
Nikolai Shelkovenko是一名振動分析工程師,也是Vibromera的創辦人兼執行長。 15年多來,他一直在現場——而非在試驗台上——為旋轉設備進行動平衡校正:粉碎機、工業風機、破碎機、離心機、軸與主軸。正是這些實際工作催生了Balanset系列儀器——它們被設計為一種專業人員可以隨身攜帶到機器旁、在現場獨立使用的工具,而非實驗室設備。 Vibromera成立於2017年,自2023年起總部設於葡萄牙波爾圖。Balanset系列產品的研發、組裝與支援均在此完成。旗艦產品是Balanset-1A,一款用於單平面及雙平面動平衡校正與振動診斷的可攜式分析儀。 Nikolai親自參與客戶支援工作,處理各種棘手的動平衡校正案例,並參與軟體開發。他以任何語言為全球客戶提供服務。