Kalkulator Bilangan Reynolds

Hitung bilangan Reynolds dari kecepatan atau laju aliran. Indikator visual aliran laminar/transisi/turbulen. Perhitungan panjang masuk dan pengaturan fluida umum.

Re = vD/ν Laminar / Turbulen Panjang Entri Pengaturan Cairan
Preset Fluida

Hasil

Bilangan Reynolds
—
Rezim Aliran
—
Kecepatan Aliran
—
Kecepatan Kritis (Re=2300)
—
Panjang Entri Le
—
Panjang Masuk / Diameter
—
Laminar2300Transisi4000Turbulen
Visualisasi Rezim Aliran

Bilangan Reynolds

Bilangan Reynolds adalah perbandingan antara gaya inersia dan gaya viskositas dalam fluida yang mengalir:

  • v — kecepatan aliran (m/s)
  • D — diameter dalam pipa (m)
  • ν — viskositas kinematik (m²/s); 1 cSt = 10⁻⁶ m²/s
  • ρ — kepadatan fluida (kg/m³)
  • μ — viskositas dinamis (Pa·s)

Ambang Batas Rezim Aliran

Rentang ReynoldsRezimKarakteristik
Re < 2.300LaminarLapisan halus dan teratur; faktor gesekan f = 64/Re; dapat diprediksi
2.300 – 4.000TransisiTidak stabil; turbulensi sesekali; hindari mendesain di sini.
Re > 4.000TurbulenKacau; gesekan lebih tinggi; gunakan Colebrook-White untuk f

Panjang Masuk Hidrodinamik

Jarak dari saluran masuk pipa hingga profil kecepatan sepenuhnya terbentuk:

Viskositas Fluida Umum

CairanSuhuν (cSt)ρ (kg/m³)
Air20°C1.004998
Air40°C0.658992
Air80°C0.365972
Oli Hidrolik ISO VG 3240°C32870
Oli Hidrolik ISO VG 4640°C46870
Oli Hidrolik ISO VG 6840°C68880
Udara20°C, 1 atm15.61.204
Oli Mesin SAE 3040°C100880

Contoh Praktis

Contoh — Sistem Hidrolik

Diberikan: v = 2 m/s, D = 25 mm, Oli ISO VG 32 pada 40°C (ν = 32 cSt)

Re = 2 × 0,025 / (32 × 10⁻⁶) = 1,563

Rezim: Laminar (Re < 2300)

Panjang entri: Le = 0,06 × 1563 × 0,025 = 2,34 m

Kecepatan kritis untuk Re = 2300: v_crit = 2300 × 32 × 10⁻⁶ / 0,025 = 2,94 m/detik

? Tips: Pada sistem hidrolik dengan oli (ν = 30–100 cSt), aliran hampir selalu laminar karena viskositas yang tinggi. Sistem air biasanya memiliki aliran turbulen karena ν ≈ 1 cSt.

The Reynolds number Re = vD/ν is a dimensionless number that compares inertial forces to viscous forces in a flowing fluid. It predicts whether flow will be laminar (smooth) or turbulent (chaotic).

Named after Osborne Reynolds who demonstrated the transition in his famous 1883 experiment using dye in a glass tube.

For pipe flow, the critical thresholds are:

  • Re < 2,300: Laminar — fluid moves in smooth parallel layers
  • 2,300 – 4,000: Transition — flow is unstable, may switch between laminar and turbulent
  • Re > 4,000: Turbulent — chaotic mixing, eddies, higher energy loss

These thresholds are for circular pipes. For open channels and other geometries, different critical values apply.

Kinematic viscosity ν = μ/ρ, where μ is dynamic viscosity and ρ is density.

Units: m²/s or cSt (centistokes). 1 cSt = 10⁻⁶ m²/s.

Common values: water at 20°C ≈ 1 cSt; hydraulic oil VG 32 at 40°C ≈ 32 cSt; air at 20°C ≈ 15.6 cSt (much higher than water due to low density despite low dynamic viscosity).

When fluid enters a pipe, the velocity profile is initially flat (uniform). As viscous effects propagate from the wall, the profile gradually develops into the fully-developed shape (parabolic for laminar).

The entry length is the distance needed:

  • Laminar: Le ≈ 0.06 × Re × D (can be very long at high Re)
  • Turbulent: Le ≈ 4.4 × Re1/6 × D (relatively short, 10–60 diameters)

Temperature strongly affects viscosity, especially for oils. Hydraulic oil viscosity drops approximately 50% for every 20°C increase.

Example: ISO VG 46 oil is ~46 cSt at 40°C but ~200 cSt at 0°C and ~15 cSt at 80°C. This dramatically changes the Reynolds number — cold-start conditions may have very different flow regimes than operating temperature.

Water viscosity changes less dramatically: ~1.8 cSt at 0°C, ~1 cSt at 20°C, ~0.3 cSt at 80°C.

Prosedur yang dijelaskan pada halaman ini dikembangkan dan diuji langsung di lapangan oleh tim Vibromera menggunakan Balanset-1A, sebuah balancer dua saluran portabel dan penganalisis getaran untuk penyeimbangan rotor di lokasi.

Vibromera — Alat Penyeimbang dan Analisis Getaran Portabel
Instrumen dan perangkat lunak penyeimbangan lapangan profesional. Digunakan di lebih dari 50 negara.
Pelajari lebih lanjut tentang alat penyeimbang Vibromera
Kategori:

Nikolai Shelkovenko

Nikolai Shelkovenko

Nikolai Shelkovenko adalah insinyur analisis getaran sekaligus pendiri dan CEO Vibromera. Selama lebih dari 15 tahun ia telah menyeimbangkan peralatan berputar langsung di lapangan, bukan di bangku uji: mulcher, kipas industri, penghancur, sentrifus, poros, dan spindel. Dari pekerjaan itulah lahir alat-alat Balanset — dirancang sebagai alat yang dapat dibawa oleh seorang spesialis ke mesin dan digunakan sendiri, di lokasi, bukan sebagai peralatan laboratorium. Vibromera didirikan pada tahun 2017 dan sejak 2023 berbasis di Porto, Portugal. Pengembangan, perakitan, dan dukungan untuk lini Balanset semuanya dilakukan di sini. Instrumen andalannya adalah Balanset-1A, penganalisis portabel untuk penyeimbangan satu dan dua bidang serta diagnostik getaran. Nikolai terlibat langsung dalam dukungan pelanggan, penanganan kasus penyeimbangan yang rumit, dan pengembangan perangkat lunak. Ia bekerja dengan pelanggan di seluruh dunia, dalam bahasa apa pun.

WhatsApp
Balanset-1A - €1975Tanyakan kepada insinyur