Kalkulator for balanserende plattformdesign
Design en balanseringsplattform (myk støtte) for balansering av feltrotorer. Beregn nødvendig fjærstivhet, egenfrekvens, statisk nedbøyning og transmissibilitet.
Resultater
Plattformens naturlige frekvens
Den naturlige frekvensen til plattformens masse-fjærsystem:
Hvor mtotalt = mrotor + mplattform og ktotalt er den kombinerte stivheten til alle fjærer (N/m).
Nødvendig stivhet per fjær
Hvor n er antall fjærer og fmål = o/min/60 × forhold (f.eks. ×1/3).
Overførbarhet
Udempet transmissibilitet ved driftshastighet:
For gode balanseringsforhold bør T være mindre enn 15%. Et frekvensforhold på 3 gir T ≈ 12,5%.
Statisk avbøyning
Praktisk eksempel
Gitt: mrotor = 80 kg, m²plattform = 15 kg, 1800 o/min, 4 fjærer, utvekslingsforhold 1/3
mtotalt = 95 kg, fpå = 30 Hz, fmål = 10 Hz
ktotalt = 95 × (2π×10)² = 375 055 N/m = 375,1 N/mm
kper vår = 375.1 / 4 = 93,8 N/mm
δstatisk = 95 × 9,81 / 375 055 × 1000 = 2,49 mm
T = 1/(3²-1) = 12.5%
⚠️ Merk: Sørg for at alle fjærene har lik stivhet og at lasten er sentrert. Ujevn nedbøyning forårsaker vipping, noe som forvrenger vibrasjonsavlesningene under balansering.
A balancing platform (soft support) is a simple structure — typically a steel frame or plate — mounted on springs. It supports a rotor for field balancing by allowing free vibration response at operating speed. The platform's natural frequency is tuned well below operating speed (typically ≤ 1/3).
The natural frequency must be well below operating speed to ensure the system operates in the isolation region — above the resonance peak. At a frequency ratio of 3, transmissibility drops to about 12.5%, meaning the rotor vibrates freely and the balancing instrument can accurately detect unbalance.
Common configurations:
- 4 springs — most common, one at each corner
- 2 springs — small, lightweight rotors
- 3 springs — triangular platforms
- 6–8 springs — large, heavy rotors
All springs must have equal stiffness and the load must be centered.
Welded steel frame or plate (10–20 mm thick) is most common. Aluminum for smaller rotors. Platform mass is typically 10–25% of rotor mass. Ensure the platform is flat and all spring mounting points are at equal height.
Yes, but rubber mounts have higher damping (reducing measurement precision), and stiffness varies with temperature and load history. Coil springs are preferred for their consistent, well-defined stiffness and low damping. Dynamic rubber stiffness is typically 1.3–2× higher than static stiffness.
Prosedyrene som er beskrevet på denne siden, ble utviklet og testet i felt av Vibromera-teamet med Balanset-1A, en bærbar tokanals balanserer og vibrasjonsanalysator for balansering av rotorer på stedet.
Profesjonelle feltbalanseringsinstrumenter og programvare. Design din balanseringsplattform og verifiser resultatene med våre bærbare balanseringsmaskiner. Brukes i over 50 land.