馬達電氣故障頻率計算器

計算同步轉速、轉差率、2× 電源頻率、極通過頻率、轉子條通過頻率及診斷邊帶,用於電動機分析。

轉差率 2× 電源 極通過 轉子條
快速預設

結果

同步轉速
—
轉差率
—
轉差頻率
—
1× 電源頻率
—
2× 電源頻率
—
極通過頻率
—
軸頻率 (1×)
—

同步轉速

交流感應電動機的同步轉速取決於電源頻率和極數:

轉差率

轉差率是同步轉速與實際轉子轉速之間的差值,以分數或百分比表示:

標準感應電動機的典型滿載轉差率為 1–5%。

轉差頻率

2× 電源頻率

由於交變磁場,此頻率(50 Hz 電源為 100 Hz,60 Hz 電源為 120 Hz)始終存在於電動機振動中。2× 電源頻率升高表示電氣問題:相不平衡、氣隙偏心或定子繞組故障。

極通過頻率

極通過頻率是斷條分析的重要指標。電流頻譜(MCSA)中 1× 電源頻率周圍的極通過頻率邊帶是轉子條故障的典型特徵。

轉子條通過頻率

實務範例

範例 — 4 極電動機,50 Hz,1475 RPM

已知: f電源 = 50 Hz,極數 = 4,N = 1475 RPM

Ns = 120 × 50 / 4 = 1500 RPM

s = (1500 − 1475) / 1500 = 1.67%

f轉差率 = 0.0167 × 50 = 0.833 Hz

2× 電源 = 2 × 50 = 100 Hz

極通過頻率 = 2 × s × f電源 = 2 × 0.0167 × 50 = 1.67 Hz

⚠️ 注意: 電動機轉速隨負載變化。請確保使用運轉條件下實際測量的轉速,而非銘牌轉速。使用轉速計或頻閃儀測量可為依賴轉差率的計算提供最準確的結果。

2× line frequency (2FL) is 100 Hz for 50 Hz systems and 120 Hz for 60 Hz systems. It is the vibration frequency generated by the alternating magnetic attraction in the motor air gap (the magnetic field reverses twice per cycle, creating a force at 2× the supply frequency).

It is always present in motor vibration at some level. Elevated 2FL can indicate:

  • Stator eccentricity (uneven air gap)
  • Shorted stator laminations
  • Unbalanced supply voltage or phase problems
  • Loose stator iron

Broken rotor bars produce characteristic patterns in both vibration and current spectra:

  • Current spectrum (MCSA): Sidebands at fline ± n × fpole pass around the supply frequency peak
  • Vibration: Rotor bar pass frequency with sidebands at 2× line frequency
  • Amplitude modulation: The 1× vibration amplitude varies at pole pass frequency rate
  • Speed variation: Slight cyclic speed fluctuation at pole pass frequency

The severity is judged by the amplitude difference (dB) between the line frequency peak and the pole-pass sidebands in the current spectrum.

Both electrical and mechanical unbalance produce vibration at or near 1× shaft speed. The key tests:

  • Power-off test: Turn off power and observe. If vibration drops instantly at disconnect, it's electrical. If it coasts down with speed, it's mechanical.
  • Frequency precision: Electrical unbalance peaks appear at exact line frequency or 2× line. Mechanical unbalance appears at shaft running speed.
  • Sidebands: Electrical problems show sidebands at slip frequency or pole pass frequency around line frequency harmonics.

Slip frequency is the electrical frequency corresponding to the difference between synchronous and actual rotor speed:

fslip = s × fline

where s = (Ns − N) / Ns

Slip is essential for torque production in induction motors — without slip, no current is induced in the rotor. Typical full-load slip values:

  • Large motors (>100 kW): 1–2%
  • Medium motors (10–100 kW): 2–4%
  • Small motors (<10 kW): 3–5%

Systematic approach to identifying fault origin:

  • Step 1 — Power-off test: Instantly disappearing vibration = electrical source
  • Step 2 — Frequency analysis: Peaks at exact multiples of line frequency = electrical; peaks at shaft speed multiples = mechanical
  • Step 3 — Sideband analysis: Slip-related sidebands = rotor electrical fault; bearing frequencies = mechanical
  • Step 4 — Current analysis: Use MCSA to identify rotor bar, eccentricity, or stator faults independently of vibration
  • Step 5 — Phase analysis: Electrical 2× line is typically in-phase across all measurements; mechanical unbalance shows phase shift between positions

本頁所述的操作流程由 Vibromera 團隊使用 Balanset-1A(一款用於現場轉子平衡的便攜式雙通道動平衡儀及振動分析儀)開發並經過實地測試。

Vibromera — 便攜式動平衡校正與振動分析
用於電動機診斷、現場動平衡和狀態監測的專業振動分析儀器。已應用於 50 多個國家。
了解更多 Vibromera 動平衡儀器資訊
分類:

Nikolai Shelkovenko

Nikolai Shelkovenko

Nikolai Shelkovenko是一名振動分析工程師,也是Vibromera的創辦人兼執行長。 15年多來,他一直在現場——而非在試驗台上——為旋轉設備進行動平衡校正:粉碎機、工業風機、破碎機、離心機、軸與主軸。正是這些實際工作催生了Balanset系列儀器——它們被設計為一種專業人員可以隨身攜帶到機器旁、在現場獨立使用的工具,而非實驗室設備。 Vibromera成立於2017年,自2023年起總部設於葡萄牙波爾圖。Balanset系列產品的研發、組裝與支援均在此完成。旗艦產品是Balanset-1A,一款用於單平面及雙平面動平衡校正與振動診斷的可攜式分析儀。 Nikolai親自參與客戶支援工作,處理各種棘手的動平衡校正案例,並參與軟體開發。他以任何語言為全球客戶提供服務。