Møt Vibromera.com — vår nye internasjonale nettside. Besøk Vibromera.com →

Gratis ingeniørverktøy

Motorslipp og kalkulator for faktisk turtall

Beregn synkron hastighet, faktisk turtall, slipprosent og slipfrekvens for induksjonsmotorer. Skriv inn turtall for å finne slip, eller skriv inn slip for å finne turtall.

50/60 Hz 2–12 poler Ns = 120f / P
Hurtigforhåndsinnstillinger

Resultater

Synkron hastighet
-
Faktisk rotorhastighet
-
Slipp
-
Slipfrekvens
-
Rotorens elektriske frekvens
-

Synkron hastighet

Den synkrone hastigheten til det roterende magnetfeltet i en induksjonsmotor:

  • f — linjefrekvens (Hz): 50 Hz eller 60 Hz
  • P — antall poler

Slipp

Motorslipp er den relative forskjellen mellom synkron hastighet og faktisk rotorhastighet:

Faktisk hastighet fra glidning

Slipfrekvens

Frekvensen til strømmene som induseres i rotoren:

Referanse for synkrone hastigheter

Poler50 Hz (o/min)60 Hz (o/min)
230003600
415001800
610001200
8750900
10600720
12500600

Praktisk eksempel

Eksempel — 4-polet motor ved 50 Hz

Gitt: f = 50 Hz, P = 4 poler, merkeskilt turtall = 1450

Ns = 120 × 50 / 4 = 1500 o/min

s = (1500 - 1450) / 1500 × 100 = 3.33%

fslipp = 3,33/100 × 50 = 1,67 Hz

frotor = s × f = 0,0333 × 50 = 1,67 Hz

Tips: Slipfrekvens er en nøkkelindikator i vibrasjonsanalyse. En karakteristisk vibrasjon ved 2 × slipfrekvens (2 × fslipp) sidebånd rundt linjefrekvensen indikerer ofte problemer med rotorstangen i induksjonsmotorer.

⚠️ Merk: Merkeskiltets turtall representerer fulllasthastighet. Ved delvis belastning vil den faktiske hastigheten være høyere (lavere slipp). Uten belastning er slippen vanligvis 0,5–1%.

Motor slip is the difference between the synchronous speed of the rotating magnetic field and the actual rotor speed in an induction motor, expressed as a percentage:

s = (Ns − N) / Ns × 100%

Slip is essential for torque production. Without relative motion between the rotor and the magnetic field, no voltage would be induced in the rotor conductors, and no torque would be generated.

Typical full-load slip values:

  • 1–3% — Large motors (>100 kW)
  • 2–5% — Standard motors (NEMA Design B)
  • 3–7% — Small motors (fractional HP)
  • 5–13% — High-slip motors (NEMA Design D)

At no load, slip is typically 0.5–1%. Slip increases proportionally with load up to the breakdown torque point.

Slip exists because an induction motor works on the principle of electromagnetic induction:

  • The stator creates a rotating magnetic field at synchronous speed Ns
  • This field must "cut" the rotor conductors to induce a voltage (Faraday's Law)
  • The induced voltage drives current through the rotor bars, creating rotor magnetic field
  • Interaction of stator and rotor fields produces torque

If the rotor reached synchronous speed, there would be zero relative motion, zero induced EMF, zero rotor current, and zero torque. Therefore, the rotor always runs slightly slower than the field.

Load and slip are directly related:

  • No load: Very low slip (0.5–1%), motor runs near synchronous speed
  • Increasing load: Motor slows down → slip increases → more rotor current → more torque
  • Full load: Slip reaches nameplate value (typically 2–5%)
  • Overload: Slip continues to increase up to breakdown torque (typically 2–3× rated torque)
  • Beyond breakdown: Motor stalls — torque decreases rapidly with increasing slip

The slip-torque curve is approximately linear from no-load to full-load for normal operation.

Motor slip can be measured using several methods:

  • Tachometer: Measure actual RPM with contact or optical tachometer and compare to synchronous speed
  • Stroboscope: Flash at line frequency — if rotor appears to slowly rotate backward, the slow rotation rate equals slip speed
  • Vibration analysis: Detect slip frequency sidebands around line frequency in the vibration spectrum (2× slip frequency sidebands indicate rotor issues)
  • Nameplate method: Use nameplate RPM as full-load speed and calculate: s = (Ns − Nnameplate) / Ns

For vibration analysts, monitoring slip frequency is critical for detecting broken rotor bars and rotor eccentricity.

Prosedyrene som er beskrevet på denne siden, ble utviklet og testet i felt av Vibromera-teamet med Balanset-1A, en bærbar tokanals balanserer og vibrasjonsanalysator for balansering av rotorer på stedet.

Vibromera — Bærbar balansering og vibrasjonsanalyse
Profesjonelle feltbalanseringsinstrumenter og programvare. Oppdag rotorstangdefekter og motorfeil gjennom vibrasjonsanalyse. Brukes i over 50 land.
Les mer om Vibromeras balanseringsinstrumenter
Kategorier:

Nikolai Shelkovenko

Nikolai Shelkovenko

Nikolai Shelkovenko er vibrasjonsanalyseingeniør samt grunnlegger og daglig leder i Vibromera. I mer enn 15 år har han balansert roterende utstyr ute i felt i stedet for på en prøvebenk: mulchmaskiner, industrivifter, knusere, sentrifuger, aksler og spindler. Det er ut av dette arbeidet Balanset-instrumentene har vokst — de ble utformet som et verktøy en fagperson kan ta med til maskinen og bruke alene på stedet, ikke som laboratorieutstyr. Vibromera ble grunnlagt i 2017 og har siden 2023 hatt base i Porto i Portugal. Utvikling, montering og støtte for Balanset-serien skjer her. Flaggskipet er Balanset-1A, en bærbar analysator for balansering i ett og to plan og for vibrasjonsdiagnostikk. Nikolai deltar personlig i kundestøtten, i arbeidet med vanskelige balanseringssaker og i utviklingen av programvaren. Han jobber med kunder over hele verden, på alle språk.

WhatsApp
Balanset-1A - €1975Spør ingeniøren