Alat Kejuruteraan Percuma

Kalkulator Kaki Lembut

Periksa herotan rangka mesin dengan memasukkan bacaan penunjuk dail pada setiap kaki. Kenal pasti kaki lembut yang paling teruk, tentukan pembetulan shim dan sahkan had yang boleh diterima.

4 atau 6 Kaki Lulus / Amaran / Gagal Cadangan Shim
Pratetap pantas

Keputusan

Kaki Terburuk Dikenal Pasti
—
Status Keseluruhan
—
Shim yang Disyorkan
—
KakiBacaan (mm)Bacaan (μm)StatusShim Diperlukan

Apakah Kaki Lembut?

Kaki lembut berlaku apabila satu atau lebih kaki mesin tidak bersentuhan sepenuhnya dan rata dengan plat asas atau asas. Apabila bolt penahan pada kaki tersebut diketatkan, rangka mesin akan herot, menyebabkan tekanan dalaman yang tidak sejajar dengan galas dan pengedap.

Kriteria Penerimaan

MembacaStatusTindakan
< 0.05 mm (50 μm)LULUSBoleh diterima — tiada pembetulan diperlukan
0.05 – 0.10 mm (50–100 μm)AMARANMarginal — pembetulan disyorkan
0.10 mm (100 μm)GAGALBerlebihan — mesti dibetulkan sebelum penjajaran

Jenis Kaki Lembut

  • Kaki Lembut Selari (Jurang) — jurang seragam di bawah kaki. Disebabkan oleh shim yang hilang atau salah. Dibetulkan dengan menambah shim rata yang sama dengan jurang.
  • Kaki Lembut Sudut — jurang berbentuk baji di mana kaki bergoyang pada satu tepi. Disebabkan oleh pemesinan tidak selari. Dibetulkan dengan shim tirus atau bertingkat.
  • Kaki Lembut Berlompatan (Reaktif/Terinduksi) — disebabkan oleh daya luaran seperti regangan paip, tekanan saluran atau pengikatan pin dowel. Kaki kelihatan rata tetapi rangka terpesong. Mesti menangani sumber daya luaran.

Prosedur Pengukuran

  1. Ketatkan semua bolt kaki mesin kepada tork biasa.
  2. Pasang penunjuk dail (atau gunakan sistem penjajaran laser) pada rangka mesin berhampiran Kaki 1.
  3. Sifarkan penunjuk, kemudian longgarkan bolt pada Kaki 1.
  4. Rekodkan pergerakan maksimum penunjuk dail — ini ialah nilai soft foot pada Kaki 1.
  5. Ketatkan semula bolt pada Kaki 1.
  6. Ulangi untuk setiap kaki yang tinggal.
Shim thickness = Dial indicator reading at the soft foot

Contoh Praktikal

Contoh — Motor 4 Kaki

Bacaan: Kaki 1 = 0.02 mm, Kaki 2 = 0.08 mm, Kaki 3 = 0.03 mm, Kaki 4 = 0.15 mm

Kaki 4 = 0.15 mm → GAGAL (melebihi had 0.10 mm)

Kaki 2 = 0.08 mm → AMARAN (antara 0.05 dan 0.10 mm)

Kaki 1 dan 3 → LULUS (di bawah 0.05 mm)

Pembetulan: Tambah Kelim 0.15 mm di bawah Kaki 4, kemudian periksa semula semua kaki.

💡 Petua: Sentiasa betulkan kaki lembut sebelum melakukan penjajaran aci. Kaki lembut akan menyebabkan bacaan penjajaran menjadi tidak konsisten dan tidak boleh diulang.

⚠️ Nota: Jika melonggarkan bolt memberikan bacaan negatif (kaki terangkat), ini menunjukkan kaki lembut anjal/reaktif yang disebabkan oleh daya luaran. Jangan tambah shim — sebaliknya, kenal pasti dan lepaskan daya luaran (tegangan paip, saluran, dsb.).

Soft foot is a condition where one or more machine feet do not make complete, flat contact with the baseplate or foundation. When the hold-down bolt at that foot is tightened, it pulls the machine frame down, causing internal distortion that misaligns bearings and seals.

The term comes from the analogy of a table with one short leg — it rocks and is unstable.

Soft foot is critical because it:

  • Distorts the machine frame — causing internal bearing misalignment
  • Makes alignment non-repeatable — readings change each time bolts are tightened
  • Increases vibration — due to internal stresses and bearing preload
  • Causes premature bearing failure — from uneven load distribution
  • Wastes alignment time — if not corrected first, alignment will never converge

Always check and correct soft foot before performing shaft alignment.

Follow this procedure:

  1. Tighten all hold-down bolts to normal torque
  2. Mount a dial indicator on the machine frame near the first foot
  3. Zero the indicator
  4. Loosen the bolt at that foot (about 1/4 turn)
  5. Record the maximum indicator movement (positive = gap)
  6. Re-tighten the bolt
  7. Move to the next foot and repeat

Alternatively, modern laser alignment systems have a built-in soft foot check function that measures all feet quickly.

There are three main types:

  • Parallel (gap) soft foot — A uniform gap exists under the foot, typically due to missing, incorrect, or worn shims. Corrected by adding flat shims equal to the measured gap.
  • Angular soft foot — The foot has a wedge-shaped gap and rocks on one edge. Caused by non-parallel machining of the foot or baseplate. Corrected with tapered or stepped shims, or by machining the foot.
  • Springing (reactive/induced) soft foot — No gap exists, but external forces (pipe strain, conduit stress, dowel pin binding) distort the machine when the bolt is tightened. Cannot be corrected with shims — must address the external force.

Parallel soft foot: Add flat shims equal to the dial indicator reading under the affected foot. Use quality pre-cut stainless steel shims. Avoid using more than 3–4 shims in a stack.

Angular soft foot: Use tapered shims, stepped shims, or machine the foot surface to achieve full contact. Sometimes a thin coat of epoxy or polymer can fill small angular gaps.

Springing soft foot: Identify and relieve the external force. Common causes include pipe strain, electrical conduit stress, tight dowel pins, and foundation settling. Do not add shims for springing soft foot — it will make the problem worse.

After correction, always re-check all feet to verify the fix.

Prosedur yang diterangkan pada halaman ini telah dibangunkan dan diuji di lapangan oleh pasukan Vibromera menggunakan Balanset-1A, iaitu pengimbang dua saluran mudah alih dan penganalisis getaran untuk pengimbangan rotor di tapak.

Vibromera — Analisis Pengimbangan & Getaran Mudah Alih
Instrumen penjajaran dan analisis getaran profesional dengan pengesanan kaki lembut terbina dalam. Capai penjajaran tepat di tapak. Digunakan di lebih 50 buah negara.
Ketahui lebih lanjut tentang alat pengimbang Vibromera
Kategori:

Nikolai Shelkovenko

Nikolai Shelkovenko

Nikolai Shelkovenko ialah jurutera analisis getaran serta pengasas dan Ketua Pegawai Eksekutif (CEO) Vibromera. Selama lebih 15 tahun, beliau telah mengimbangi peralatan berputar terus di lapangan berbanding di bangku ujian: mulcher, kipas industri, penghancur, sentrifug, aci dan gelendong. Kerja inilah yang menjadi asal usul instrumen Balanset — ia direka sebagai alat yang boleh dibawa oleh pakar terus ke mesin dan digunakan bersendirian, di tapak, bukan sebagai peralatan makmal. Vibromera diasaskan pada 2017 dan telah berpangkalan di Porto, Portugal, sejak 2023. Pembangunan, pemasangan dan sokongan siri Balanset semuanya dijalankan di sini. Instrumen unggulan kami ialah Balanset-1A, penganalisis mudah alih untuk pengimbangan satu dan dua satah serta diagnostik getaran. Nikolai terlibat secara peribadi dalam sokongan pelanggan, menyelesaikan kes pengimbangan yang sukar, dan dalam pembangunan perisian. Beliau bekerja dengan pelanggan di seluruh dunia, dalam apa jua bahasa.